• Title/Summary/Keyword: Saturation rate

Search Result 806, Processing Time 0.025 seconds

Comparison of oxygen saturation, heart rate of cerebral palsy and normal child between the pre-ambulation and post-ambulation (뇌성마비아동과 정상아동의 보행전후 산소포화도 및 심박수 비교에 관한 연구)

  • Hwang, Joo-Moon;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.38-46
    • /
    • 2003
  • Since the current tendencies show us the increasing number of cerebral palsy children and the standard longevity, we need to find out more research about the following various problems. Therefore I have tried to figure out the difference of oxygen saturation and heart rate between before ambulation and after. Objects chosen are 17 C.P children on the process of treatment those who were able to walk and 8 normal children in Ah-San hospital, Gang-Nung. They haven't had either any operation or suffered heart disease and I measured their oxygen saturation and heart rate by using pulse-oximeter and are analyzed by SPSS (10.07 version). Results are the followings; 1. There was no difference of oxygen saturation and heart rate between pre-ambulation and post-ambulation of normal and spastic hemiplegia children. 2. There showed the significant statistic difference of oxygen saturation, heart rate between pre-ambulates and post-ambulation of normal and spastic diplegia(p<.05). 3. There was no difference of oxygen saturation, heart rate in C.P between(p>.05), but shows the significant statistic difference in heart rate(p<.05). As I compared the oxygen saturation and heart rate of spastic and normal children on between pre-ambulation and post-ambulation, theres is significant statistic difference on both items (p<.05). However there was no difference of oxygen saturation among hemiplegia, normal and diplegia children while the pulse rate showed the significant difference(p<.05). According to this clinical research, CP children's oxygen saturation and heart rate had no change between pre and post compared to normal children. But there was difference in diplegia. This is why we need to invest time to study these kinds of research about various analysis and comparison of oxygen saturation and heart rate, and furthermore making use of pulse-oxymetry in physical therapy room for the children involved would be beneficial to calculate in accuracy without any discomfort for the patient as well.

  • PDF

Ideal Saturation Flow Rate and Geometric Adjustment Factors at Urban Signalized Intersection (도시부 신호교차로의 기본용량 및 기하구조 보정계수)

  • 오영태;심대영
    • Journal of Korean Society of Transportation
    • /
    • v.10 no.2
    • /
    • pp.5-24
    • /
    • 1992
  • This research presets the method of determining basic capacity of signalized intersection using the concept of ideal saturation flow rate. Vehicle discharge rates during green time were collected and studied as part of the preparation of Korean Highway Capacity Manual. From the result of this study the ideal saturation flow rate and saturation queue position were determined. In addition, based on the ideal saturation flow rate two geometric adjustment factors(lane width and grade adjustment factors) were studied. The results were presented in this paper.

  • PDF

Analysis of Saturation Flow Rate on Interrupted Flow During Rainfall (강우시 단속류 포화교통류율 변화 분석)

  • Kim, Bongseok;Roh, Chang-Gyun;Son, Bongsoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • The climate of Korea has clear rainy and dry season due to seasonal wind. In general, The rainy season in Korea is from early summer through to early fall. And precipitation accounted for more than half of the total annual rainfall in this period. This study is aiming to analysis of variation in saturation flow rate at signalized intersection during rainfall. The range of spatial is urban signalized intersections in Seoul and temporal is rainfall or ideal condition in daylight. Traffic data are collected through CCTV of Seoul Metropolitan Police Agency, and on-site video recordings directly. Weather condition data are collected from the Korea Meteorological Administration. In addition, the value of saturation headway and saturation flow rate, in rainfall condition, are derived through video frame analysis. As a results of analysis, decrease of saturation flow rate and increase of saturation headway during rainfall were confirmed by comparison with non-rainfall. The higher rainfall rate is, the more decreased saturation flow rate at the intersections. Rainfall rate is divided three area by the results of statistical test, and saturation flow rate decrease 7%, 17%, 21%, respectively.

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

Effects of Covering Newborn's Head after Bath on Body Temperature, Heart Rate and Arterial Oxygen Saturation

  • Kim, Dong-Yeon;Park, Ho-Ran
    • Child Health Nursing Research
    • /
    • v.18 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • Purpose: In this study changes were observed in body temperature, heart rate and arterial oxygen saturation (SaO2) of newborns after bathing and to determine the effects of covering their heads with cotton hats after bathing. Methods: Participants were 58 newborn infants, 31 in the experimental group had their heads covered with cotton hats after their bath while 27 in the control group did not. Body temperature, arterial oxygen saturation and heart rate were measured at 8 consecutive times after bathing. Data were analyzed using t-test and repeated measures ANOVA. Results: Body temperature declined shortly after bathing. The experimental group showed faster recovery (p<.001). Heart rate increased after bathing in both groups. Heart rate in the experimental group decreased for 120 minutes and gradually increased to baseline (p<.001). In the control group, heart rate decreased for 180 minutes and then increased but did not reach the baseline (p<.001). Arterial oxygen saturation decreased shortly after bathing and recovery to the baseline was more rapid in the experimental group (30 minutes vs. 60 minutes) (p<.001). Conclusion: With significant changes observed in newborns' body temperature, arterial oxygen saturation and heart rate, covering the head right after bathing is effective in stabilizing infants' physiological system.

Changes in Verbal Cognitive Performance, Blood Oxygen Saturation and Heart Rate due to 30% Oxygen Administration (30% 산소 공급에 의한 언어 인지 능력, 혈중 산소 농도, 심박동율의 변화)

  • Chung Soon Cheol;Sohn Jin Hun;Tack Gye Rae;Yi Jeong Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.173-180
    • /
    • 2005
  • In this study, changes in verbal cognitive performance, blood oxygen saturation and heart rate due to 30% concentration oxygen supply were observed. Five male (24.6±0.9) and five female (22.2±1.9) college students were asked to perform 28 verbal cognitive tasks of the same difficulty during two types of oxygen (concentration 21%, 30%) administration. The experimental sequence consisted of Rest1 (1 min.), Control (1 min.), Task (4 min.), and Rest2 (4 min.) and the physiological signals such as blood oxygen saturation and heart rate were measured throughout the stages. The experimental result showed that the performance increased significantly at 30%'s concentration of oxygen rather than 21%'s, which shows oxygen supply has positive influence on verbal cognitive performance. When 30% concentration oxygen is supplied, the oxygen saturation in the blood significantly increased comparing to 21%. The heart rate showed no significant difference. Significant correlations were found between changes in oxygen saturation and cognitive performance. It is suggested that 30% oxygen can stimulate brain activation by increasing actual blood oxygen concentration in the process of cognitive performance.

Effects of Nonnutritive Sucking on Heart Rate, Oxygen Saturation and Behavioral State in Premature Infants (노리개젖꼭지 제공이 미숙아의 심박동수, 산소포화도 및 행동상태에 미치는 효과)

  • Park, Jin-Hee;Park, Ho-Ran
    • Child Health Nursing Research
    • /
    • v.13 no.3
    • /
    • pp.299-307
    • /
    • 2007
  • Purpose: To investigate the effect of nonnutritive sucking(NNS) on the heart rate, oxygen saturation, and behavioral state of premature infants. Method: From December 15, 2004 to February 15, 2005, 20 premature infants hospitalized in the neonatal intensive care units were assigned to an experimental group (10), or a control group (10). Circular pacifiers for premature infants (Johnson, U.S.A.), which had been packed with $2{\times}2$ gauzes to create a vacuum, were used for 5 minutes, one hour after feeding for 5 days. Heart rates and oxygen saturation were checked every minute for 10 minutes once a day and behavioral states were monitored through video recording at the same time. Results: Changes in heart rate, oxygen saturation and behavioral state were found to show significant differences between the experimental group and the control group according to the point in time, and interactions were found between the group and the point of time. However, for behavioral state, no significant difference was found between the experimental group and the control group after the NNS was removed. Conclusion: From the results of this study it is possible to conclude that NNS is a positive intervention to bring about increased oxygen saturation and soothed behavioral state for premature infants.

  • PDF

A Comparison of the Opened Versus Closed-System of Suctioning -In Oxygen Saturation, Vital Signs and Suction Time- (개방형 흡인술과 폐쇄형 흡인술이 인공호흡기 사용 중환자의 산소포화도와 활력징후에 미치는 효과)

  • Seo, Min-Sook;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.141-154
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the difference of change in oxygen saturation, vital signs and suction time taken for the suctioning during endotracheal suctioning performed with closed suction system and with opened suction system. Methods: Data were collected from 31 adult patients with ventilator treatment who were admitted to a university hospital in Seoul and the collection period was from July 1 to November 15, 2005. Oxygen saturation, heart rate, respiration rate and mean arterial pressure were collected immediately prior to the suctioning intervention, during and 1 and 5 minutes after the suctioning from opened suction system and closed suction system. Results: 1) The difference in oxygen saturation was statistically significant in recovery time for oxygen saturation to return to baseline values after suctioning was significantly rapid on closed suction system (p<.05). 2) The difference in heart rate, respiration rate and mean arterial pressure was statistically insignificant 3) The suction time was shorter in closed suction system. Conclusion: Closed suction system is more efficient, as compared with the open suction system in the ventilator treatment.

  • PDF

Equivalent Circuit Analysis of Single Phase Induction Motor Considering Magnetic Saturation Characteristics (자기포화 특성을 고려한 단상유도전동기의 등가회로 해석)

  • Kim, Young Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.270-277
    • /
    • 2013
  • Single phase induction motor(SPIM) is used widely because it is driven by single phase source. However, the efficiency of the motor is not good due to saturation of magnetic material. To analyze the motor accurately, the magnetic saturation characteristics should be considered in analysis of equivalent circuit. In this paper, lumped parameter of circuit are derived from multi phase induction motor using method of symmetrical coordinates. Also, we presents a method for the equivalent circuit analysis of SPIM using magnetic saturation rate. The magnetic nonlinearity is considered deriving magnetizing reactance from voltage-current saturation curve. As a results, current characteristic, torque, output and efficiency are shown through analysis of equivalent circuit. A simulation results of SPIM will be used to improve the characteristics and efficiency of motor.

Development of Saturation Flow Rate Estimation Models Considering Workzone in the Vicinity of Signalized Intersections (도시부 신호교차로 인근 도로점용공사를 고려한 포화교통류율 산정모형 개발에 관한 연구)

  • Eo, Hyo-Gyeong;Sin, Chi-Hyeon
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.6
    • /
    • pp.109-120
    • /
    • 2010
  • This study aims to develop mathematical models for estimating saturation flow rates at the stop line of signalized intersection due to Workzones in the vicinity, since the saturation flow rate is the most critical parameter in capacity analysis for signalized intersections. It was found by reference review that saturation flow rates are sensitively influenced by the location of Workzone, the number of lanes, cycle length and effective green time. Extensive microscopic simulation runs were also performed and compared to the those of mathematical models for model verification. Mathematical models were developed based on traffic flow theory and dualizing them by the location of workzones. And then each result produced by changing important parameter values was carefully examined and analyzed. Small but consistent differences in saturation flow rate values between mathematical models and simulations exist. However, the pattern of changes in saturation flow rates depending on each variable was similar.