• Title/Summary/Keyword: Saturation Efficiency

Search Result 297, Processing Time 0.03 seconds

Study on Analysis of Single Phase Induction Motor Considering Saturation Factor (포화계수를 고려한 단상 유도전동기의 해석에 관한 연구)

  • Cho, Su-Yeon;Kim, Kwang-Soo;Im, Jong-Bin;Ryu, Gwang-Hyeon;Oh, Se-Young;Ahn, Han-Woong;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.846-847
    • /
    • 2011
  • This paper presents the study on analysis of single phase induction motor characteristics by equivalent circuit. For high efficiency of single phase induction motor, the motor parameters used for equivalent circuit analysis is important. The accuracy of equivalent circuit analysis of motor depends on the circuit parameters like saturation factor. Therefore this paper proposed the analysis method considering saturation factor. The saturation factor was calculated by iteration routine and numerical method. this proposed method was verified by FEM analysis results and dynamo test results of the prototype model.

  • PDF

Characteristics Analysis of Single Phase Induction Motor via Equivalent Circuit Method and Considering Saturation Factor

  • Cho, Su-Yeon;Kim, Won-Ho;Jin, Chang-Sung;Kang, Dong-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.178-183
    • /
    • 2014
  • This paper presents a motor characteristics analysis method using an equivalent circuit. Motor characteristics analysis via equivalent circuit is very important for designing a high efficiency single phase induction motor. The accuracy of the motor characteristics depends on the accuracy of the parameters, especially saturation factor, which determines the cyclical relationship in the analysis process. Therefore, using the proposed method, the saturation factor was calculated using the iteration routine and numerical technique. The proposed method was verified by comparing the finite element method results and the dynamo test results of manufactured prototype model.

The Characteristics of Electrokinetic Remediation of Unsaturated Soil II : Numerical Analysis (불포화토의 동전기 정화 특성 II : 수치 해석적 연구)

  • Kim, Byung Il;Han, Sang Jae;Kim, Soo Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1C
    • /
    • pp.9-17
    • /
    • 2006
  • The numerical analysis to predicting the electrokinetic remediation behavior on unsaturated soil is carried out by aiding HERO, Hanyang Unversity Electrokinetic Remediation program, developed from the finite difference method and in the VISUAL FORTRAN environment. The analysis for the pure kaolinite under saturated conditions is performed on the results of the previous study of Acar (1997). Also the predictions to the characteristics of electrokinetic remediation on unsaturated conditions are performed and the conclusions summarized as follows. First, pH of the electrolyte in the reservoirs is not different with the degree of saturation resulted from the changes in electrical efficiency. But the advance of acid front is increased dependent on the degree of saturation in contrary to the transportation of base front. Second, below the degree of saturation of 83%, which is equivalent to the optimum water content, the removal effect increased with the decreasing of degree of saturation. But it have no effect on the efficiency of removal over the degree of saturation of 83%.

The Absorption Saturation and Diffraction Efficiency of the Permanent Gratings Due to the Photodarkening in Semiconductor Doped Glasses (반도체가 첨가된 유리의 암색화에 따른 포화흡수 변화와 영구 회절격자의 회절효율 연구)

  • Baek, Sung-Hyun;Shin, Sang-Hoon;Kim, Sang-Cheon;Choi, Moon-Goo;Park, seung-Han;Kim, Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.331-336
    • /
    • 1995
  • The steady-state absorption saturation of the photodarkend SDG was investigated. The absorption saturation intensity was observed to increase for the photodarkened sample. The diffraction efficiency of the permanent grating due to photodarkening was also measured using the backward DFWM technique. For the low backward pump intensity, the diffraction efficiency was proportional to the intensity of the pump beam. The origin of increasing diffraction efficiency is attributed to the difference in absorption between the permanent gratings created by photodarkening. ening.

  • PDF

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

The Characteristics of Electrokinetic Remediation for Unsaturated Soil (불포화토의 동전기정화 특성에 관한 실험적 연구)

  • 김병일;김익현;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.641-646
    • /
    • 2003
  • In this study, a series of electrokinetic(EK) remediation experiments are carried out under the different degree of saturation for contaminated soil with lead. for constant electrical potential, the final current of all the sample represents the similarity to steady-state value of 5∼7mA. Under conditions of all the degree of saturation the anode reservoir becomes acidic(pH as low as 3) while the cathode reservoir is basic(pH as high as 12). But pH changes in the sample is a little and decontamination efficiency is the low.

  • PDF

Design of Nonlinear Controller for Tracking Control based on Genetic Fuzzy algorithm (유전 퍼지 알고리즘 기반의 추종 제어를 위한 비선형 제어기 설계)

  • Kong, Jung-Shik;Ahn, Sang-Min;Lee, Bo-Hee;Kim, Jin-Geol;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2684-2686
    • /
    • 2005
  • This paper presents design of nonlinear controller based on genetic-fuzzy algorithm. Motor system that is included at a humanoid robot has many nonlinear parameters such as saturation, backlash and so on. So, it is hard to control a humanoid robot because of these nonlinearities. Also, tracking following ability is also reduced by these nonlinearities. In this paper, fuzzy PID controller is proposed for reducing efficiency by saturation. At that time, genetic algorithm is supplied at making fuzzy rule in order to make optimal fuzzy PID controller. Also, disturbance observer is used to reduce the efficiency of backlash. All these processes are verified by simulation and experiment in the real humanoid robot.

  • PDF

Parameter Identification of an Induction Motor Drive with Magnetic Saturation for Electric Vehicle

  • Jeong, Yu-Seok;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.418-423
    • /
    • 2011
  • This paper presents a simulation model and a parameter identification scheme of an induction motor drive for electric vehicle. The induction motor in automotive applications should operate in very high efficiency and achieve the maximum-torque-per-ampere (MTPA) feature even with saturated magnetic flux under very high torque. The indirect vector control which is typically adopted in traction drive system requires precise information of motor parameters, particularly rotor time constants. This work models an induction motor considering magnetic saturation and proposes an empirical identification method using the current controller in the synchronous reference frame. The proposed method is applied to a 22kW-rated induction motor for electric vehicle.

A Study on the Stability of Control for Nonlinear Saturated Systems (비선형 포화시스템 제어에 관한 안정성 연구)

  • 정상화;오용훈;류신호;김상석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.208-208
    • /
    • 2000
  • In realistic control systems, the nonlinear salutation attributes of the control actuator due to physical limitations should be taken into account. This nonlinear saturation of actuators may cause not only deterioration of the control performance but also a large overshoot during start-up and shut-down. As the overshoot increases, the system may become oscillatory unstable. In this paper, the supervisor implementation which guarantees good performance lot saturation operation and prevents reset wind-up is presented. Moreover, the sufficient conditions of the stability for saturated systems using supervisory control with a dynamic controller are provided in the discrete-time domain. A numerical example is illustrated to depict the efficiency of supervisory control for a typical saturated production-distribution system controlled by a discrete-time dynamic controller and to validate basic results by simulation.

  • PDF

Anti-Saturation Algorithm for a Load Sensing Hydraulic Servo System with Multiple Actuators (다중 작동기를 가진 부하감응 유압서보장치의 포화방지 알고리즘)

  • 이춘호;최필환;김철수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.977-981
    • /
    • 1996
  • A load sensing hydraulic system is widely used to military and commercial mobile applications fur its high running efficiency. Although concept and general control schemes are well known, the poor maneuverability of simultaneous multioperation of actuators still remains to be solved. In this paper, a new control algorithm is proposed to prevent the saturation of the system in such operating conditions, in which the total required flowrate of actuators may exceed the pump supply flowrate. The effectiveness of the proposed algorithm is verified through experiments.

  • PDF