• Title/Summary/Keyword: Saturation Curve

Search Result 225, Processing Time 0.03 seconds

Extrapolating B-H Curve Data using Common Electrical Steel Characteristics for High Magnetic Saturation Applications

  • Chai, Seung-Hee;Kim, Ji-Hyun;Kim, Sung-Il;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.258-264
    • /
    • 2015
  • In this paper, an adequate B-H curve extrapolation method is proposed and its reliability is verified through experiments. A method is developed to estimate the magnetic saturation induction from the density of the lamination core and electrical resistivity. The magnetic saturation induction of electrical steels measured using a vibration sample magnetometer are compared with the analytical results to validate the accuracy of the proposed estimation method. It is found that the predicted error in the magnetic saturation induction of the electrical steels are approximately 1.2% when the proposed method is used. The performance of interior permanent magnet synchronous motors that applies the proposed method are evaluated via 2D nonlinear finite element analysis and through experiments. Based on the obtained results, the extrapolated B-H curves from the estimated saturation induction can be used for various analyses in saturation region.

A Busbar Current Differential Relay with a Compensating Algorithm (보상 알고리즘을 적용한 모선보호용 전류차동 계전기)

  • 강용철;윤재성
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.214-220
    • /
    • 2004
  • This paper describes a busbar current differential relay in conjunction with a current transformer(CT) compensating algorithm irrespective of the level of the remanent flux. The compensating algorithm detects the start of first saturation if the third-difference function of the current exceeds the threshold; it estimates the core flux at the first saturation start by inserting the negative value of the third-difference function of the current into the magnetization curve; thereafter, it calculates the core flux during the fault and compensates the distorted current using the magnetization curve. The algorithm estimates the correct secondary current irrespective of the level of the remanent flux and needs no saturation point of the magnetization curve. The proposed relay can improve not only security of the relay on an external fault with CT saturation but sensitivity of the relay on an internal fault; the relay can improve the operating speed on n internal fault with CT saturation. This paper concludes by implementing the relay into a digital signal processor based prototype relay.

A Busbar Current Differential Relay with a Compensating Algorithm (보상 알고리즘을 적용한 모선보호용 전류차동 계전기)

  • 강용철;윤재성
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.214-214
    • /
    • 2004
  • This paper describes a busbar current differential relay in conjunction with a current transformer(CT) compensating algorithm irrespective of the level of the remanent flux. The compensating algorithm detects the start of first saturation if the third-difference function of the current exceeds the threshold; it estimates the core flux at the first saturation start by inserting the negative value of the third-difference function of the current into the magnetization curve; thereafter, it calculates the core flux during the fault and compensates the distorted current using the magnetization curve. The algorithm estimates the correct secondary current irrespective of the level of the remanent flux and needs no saturation point of the magnetization curve. The proposed relay can improve not only security of the relay on an external fault with CT saturation but sensitivity of the relay on an internal fault; the relay can improve the operating speed on n internal fault with CT saturation. This paper concludes by implementing the relay into a digital signal processor based prototype relay.

Determination of Transformer Inductances using Instantaneous Magnetic Saturation Curve (순시치 자기포화 곡선에 의한 변압기 인덕턴스 산정)

  • Hyun, Yong-Tak;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.74-77
    • /
    • 2001
  • The saturated winding inductances of a transformer are determined using the instantaneous magnetic saturation curve. The instantaneous curve is obtained from no load saturation curve in rms form by a direct piecewise linearized approach, then it is represented by a four-term ploynominal approximation. The saturated differential, effective and apparent winding inductances are computed from this curve, and these inductances are compared with the measured magnetizing inductance. The results show that the relation of $L_d<L_e<L_a$ exists and the computed apparent inductance is more close to the measured inductance.

  • PDF

Fixed -bed Adsorption of Food-Related Phenolic Acids on Charocal in Single Solute System

  • Lee, Won-Young;Park, Yong-Hee
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.2
    • /
    • pp.123-127
    • /
    • 1998
  • Fixed-bed adsorption was adapted to separate phenolic acids from diluted phenolic solution. Break-through curve was obtained by nonlinear curve fitting method, and breakpoint, saturation time, and mass transfer coeffi-cient were calculated . Break point and saturation time were reached slower with $\rho$-coumaric acid than ferulic acid .The p-coumaric acid, having small molecular weight, is suposedly traveled longer pathway in characoal than ferulic acid. Fixed-bed adsorption iwht gallic acid having more hydroxyl functional group than other phenolic acids showed break point arrival and the largest saturation time. This fact means that there was bigger electrostatic affinity between gallic acid and charcoal than between other phenolic acids and charcoal.

  • PDF

A Study on Change of Soil-Water Retention Curve with Different Net Confining Pressures and Porosities using a Suction-Saturation Control Technique (흡입력-포화도 조절 기법을 이용한 불포화토의 함수특성곡선에 미치는 간극비 및 순구속압력의 영향 연구)

  • Lee, Joon-Yong;Yu, Chan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.93-103
    • /
    • 2012
  • A suction-saturation control technique based on flow pump system was developed to investigate hydraulic properties in unsaturated soils. The flow pump system is designed based on the principle of the axis-translation technique and triaxial equipment, and gives the suction-time and suction-saturation curves, the primary relationship needed for interpreting the response of unsaturated soils and link between theory and the material properties in unsaturated soil mechanics. Using the suction-saturation control technique, suction-time relationship and soil-water retention curve (SWRC) during hydraulic hysteresis were investigated with different net confining pressures and porosities. Three types of soils-two sands and a silt were used in this paper. This paper showed the effect of the hysteresis on the SWRC due to different net confining pressures and porosities. This means that a careful decision must be made as to which condition is to be modeled, since the delicate difference of the conditions in physical modeling can cause the different experimental output.

A Study on the Conformity Assessment of Type Curve Models to Predict Production Performance in Coalbed Methane Reservoirs (CBM 저류층의 생산성 예측을 위한 표준곡선 모델의 적합성 평가 연구)

  • Kim, Changkyun;Lee, Jeonghwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.34-45
    • /
    • 2018
  • The cleat system in coalbed methane (CBM) reservoirs is generally occupied by water which liberated during the coalification process, and behavior of water have influence on CBM production performance. Therefore, it is essential to investigate the effect of the water saturation to operate the degasification process and predict the CBM production performance properly. In this study, type curve analyses were performed on CBM reservoirs under various water saturation to improve the prediction of production performance. A CBM reservoir models with fully-, modestly-, and undersaturated reservoir were built to get production data using GEM by CMG Ltd., and the data were matched with Fetkovich, Palacio-Blasingame(P-B), and Agarwal-Gardner (A-G) type curve. The results showed that undersaturated reservoir was successfully matched by A-G type curve, while the Fetkovich type curve was inappropriate for matching in the late time. The modestly saturated model could be almost corresponded with all the type curve methods at late production period. For the fully saturated model, after peak production had been reached, both P-B and A-G methods showed a proper match to the reservoir production data without long-term production period. Based on the results, merit and demerit of each type curve under specific water saturation were analyzed and listed. Therefore, it is believed that the production data analysis with proper type curve model considering water saturation can be performed to predict accurate production performance.

Comparative Study on Unsaturated Characteristic Curves of Boeun Granite Weathered Soil during Drying and Wetting Paths (건조 및 습윤과정에서 보은 화강암 풍화토의 불포화특성곡선 비교)

  • Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.15-24
    • /
    • 2016
  • To investigate the unsaturated characteristics of the Boeun granite weathered soil, matric suction and volumetric water content were measured in both drying and wetting paths using Automated Soil-Water Characteristics Curve Apparatus. Based on the measured results, Soil-Water Characteristics Curve was estimated by van Genuchten (1980) model. The relationship between effective degree of saturation and matric suction showed the non-linear curve with S-shape and the hysteresis phenomenon occurred during drying and wetting paths. Suction Stress Characteristics Curve was estimated by the Lu and Likos (2006) model. The suction stress in drying path was constantly maintained and that in wetting path tended to increase when the effective degree of saturation was low. But the suction stress in drying path was larger than that in wetting path at the same degree of saturation when the effective degree of saturation became larger. Meanwhile, Hydraulic Conductivity Function was evaluated by the van Genuchten (1980) model which is one of the parameter estimation methods. The unsaturated hydraulic conductivity decreased with increasing the matric suction, and the decreasing velocity regarding to the matric suction in drying path was larger than that in wetting path.

Characteristics Analysis of IPM Motor Considering Magnetic Saturation of Electrical Steel (IPM 모터 철심의 포화를 고려한 특성 해석)

  • Ha, Kyung-Ho;Ahn, Young-Jun;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1031-1032
    • /
    • 2011
  • This paper deals with the characteristics analysis of Interior Permanent Magnet Type Motor varying with magnetization curve of electrical steel interpolated with several method in the high field region. The data of magnetization curve of electrical steel given by the steel maker is not enough in order to analysis the characteristics by menas of FEM. Especially, the core in the bridge part have a severe saturation because the bridge width is narrow to reduce the flux leakage produced by the permanent magnet. This paper make the three kinds of magnetization curve by extrapolation and then the motor is analyzed by using these magnetization curve. The motor parameters are compared to explain the effects of magnetization curve.

  • PDF

A Compensated Current Acqaisition Device for CT Saturation (왜곡 전류 보상형 전류 취득 장치)

  • Ryu, Ki-Chan;Gang, Soo-Young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • In this paper, an algorithm to compensate the distorted signals due to Current Transformer(CT) saturation is suggested, First, DWT which can be easily realized by filter banks in real-time applications is used to detect a start point and an end point of the saturation. Secondly, For enough Datas those need to use the least-square curve fitting method, the distorted current signal is compensated by the AR(autoregressive) model using the data during the previous healthy section until pick point of Saturation. Thirdly, the least-square curve fitting method is used to restore the distorted section of the secondary current. Finaly, this algorithm had a Hadware test using DSP board(TMS320C32) with Doble test device. DWT has superior detection accuracy and the proposed compensation algorithm which shows very stable features under various levels of remanent flux in the CT core is also satisfactory. And this algorithm is more correct than a previous algorithm which is only using the LSQ fitting method. Also it can be used as a MU involving the compensation function that acquires the second data from CT and PT.

  • PDF