• Title/Summary/Keyword: Saturated Vapor Pressure

Search Result 54, Processing Time 0.028 seconds

The Correlation Study on the Desorption Enthalpy Changes of Sun- Cured Tobacco (향끽미종 잎담배의 탈착 엔탈피 변화에 관한 상관성 연구)

  • 최승찬
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.6 no.1
    • /
    • pp.33-37
    • /
    • 1984
  • The net enthalpy changes for the water desorption of sun-cured tobacco have been studied. In order to compare the values of net enthalpy changes for the samples at the same moisture contents, correlation analyses have been performed. The results are summarizing as followings : 1 . As temperature and water vapor pressure increased, equlibrium moisture content were approaching to the saturated vapor pressure of water. 2. The values of 1nP against the reciprocal of absolute temperature were linear for the water desorption of samples. 3. Multiple regression was analyzed to calculate the values of 1nP at the same moisture content. The significance of $x^2$-test for the multiple regression was 0.5%. 4. The values of net enthalpy changes for Basma were greater than those of Sohyang at the same moisture content.

  • PDF

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.

A Research on the Conception Change Process of Secondary School Chemistry Major Teachers Related to the Evaporation Phenomena in the Air (대기 중의 증발 현상에 대한 중등학교 화학전공 교사들의 개념 변화 과정에 대한 연구)

  • Yang, Gee-Chang;Paik, Seoung-Hey
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.1
    • /
    • pp.84-95
    • /
    • 2008
  • In this study, preconceptions held by chemistry major secondary school science teachers were searched in relation to explanations of water evaporation phenomena with phase equilibrium diagrams. 25 chemistry major science teachers were selected to complete questionnaires developed in this study and 6 among of them were selected to participate in follow-up interviews. Among these, 10 participants were selected for an evaluation of the change of their preconceptions through lessons developed in this study. From the results, it was found that many teachers believed that the phase equilibrium diagram could not explain water evaporation phenomena. They also thought that there was no relation between vapor pressure and the vertical axis of the phase equilibrium diagram. However, after the lessons in earth science, they recognized that the vapor pressure curve of the phase equilibrium diagram could be explained by adopting a saturated vapor curve. Because they had known the process of application the conceptions of saturated situation, nonsaturated situation, process of equilibrium movement in saturated vapor curve. They could understand natural phenomena such as evaporation with the phase equilibrium diagram through a change in their conceptions as guided from science lessons integrating earth science and chemistry.

Application of CFD to tile Calculation of 2 Phase Cryogenic Heat Transfer Processes (2상 극저온 열전달 과정 계산에서의 CFD 응용)

  • Liu, Jie.;Yue, Haibo;Chung, Mo;Bai, Cheol-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.141-147
    • /
    • 2011
  • A two-phase numerical model for plate-fin heat exchangers with plain fins and wave fins is studied incorporating the thermodynamic properties and the characteristics of fluid flow. The numerical simulations for the two fins in cryogenic conditions are earned out by employing a homogenous two-phase flow model with the CFD code ANSYS CFX. The heat transfer coefficients and the friction factor for nitrogen saturated vapor condensation process inside two types of plate fin heat exchanger are evaluated including the effects of saturation temperature (pressure), mass flow rate and inlet vapor quantity. The convective heat transfer coefficients and friction factors will be used for design of plate-fin type heat exchangers operating under cryogenic conditions.

  • PDF

Organic Pollutant Transport in Unsaturated Porous Media by Atmospheric Breathing Processes( I ) - Partition Coefficient -

  • Ja-Kong;Lim, Jae-Shin;Do, Nam-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.11a
    • /
    • pp.50-53
    • /
    • 1996
  • This paper reports the experimental results for the determination of the overall partition coefficient of VOCs in unsaturated soil, A chromatographic method was used for the determination of gaseous partition coefficients to natural soil under various water content conditions. The equilibrium vapor pressure of water over saturated salt solution was used to fix the relative humidity of the air and control the water content of the soil systems. The transport behavior was studied for dichloromethane, trichloroethane and dichlorobenzene pollutants, with log octanol-water partition coefficients(log $K_{ow}$ ) which range from 1.25 to 3.39, or water to soil partitioning which varies by 135 times; water solubility constants which vary by 3 times; and vapor pressures which range from 1 to 362 torr. Water content of the soil had a pronounced effect on the effective partition coefficient(between gas and soil + water stationary phase) as well as on the effective dispersion coefficient.

  • PDF

1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility (물 분무를 이용한 연소가스 냉각 1차원 해석)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The cooling of hot exhaust gas is an important issue for the construction of combustor test facility. Water spray is an effective method for exhaust gas cooling due to its large latent heat in process of evaporation. In this study, 1-D analysis has been performed based on continuity, energy conservation, and saturated vapor property to understand water spray cooling of combustion gas. In the exhaust duct of combustor test facility, the injected water decreases combustion gas temperature, and evaporates in the combustion gas. However, some of the injected water is collected in the sump due to condensation. The evaporation of water helps combustion gas cooling, but causes pressure increase inside the exhaust duct due to increase of vapor pressure. These phenomena has been analyzed by 1-D modeling in this study. From 1-D analysis, the adequate mass flow rate of water spray to cool combustion gas and to avoid excessive pressure rise inside the exhaust duct has been decided.

Effects of Light, Temperature, Water Changes on Physiological Responses of Kalopanax pictus Leaves(II) - Characteristics of Stomatal Transpiration, Water Efficiency, Vapor Pressure Deficit of Leaves by the Light Intensity - (광, 온도, 수분 변화에 따른 음나무 엽의 생리반응(II) - 광도변화에 따른 기공증산, 수분이용효율, 수증기압결핍 -)

  • Han, Sang-Sup;Jeon, Doo-Sik;Sim, Joo-Suk
    • Journal of Forest and Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research was carried out to elucidate the characteristics of stomatal transpiration, water efficiency, vapor pressure deficit of leaves by the light intensity Kalopanax pictus leaves. The results obtained are summarized as follows: 1. In the upper leaves of Kalopanax pictus seedlings, the stomatal transpiration rate increased continuously with increasing light intensity, but in the middle and lower leaves. it was saturated at $100{\mu}mol\;m^{-2}S^{-1}$. At the light saturated point. the stomatal transpiration rate was in the following order: the upper ($1.29mmol\;H_2O\;m^{-2}S^{-1}$) middle ($0.56mmol\;H_2O\;m^{-2}S^{-1}$) lower leaves ($0.31mmol\;H_2O\;m^{-2}S^{-1}$). 2. In the upper leaves, water use efficiency rapidly increased to $600{\mu}mol\;m^{-2}S^{-1}$, and then decreased. In the middle and lower leaves, it increased to $400{\mu}mmol\;m^{-2}S^{-1}$, and then showed a constant values. 3. The vapor pressure deficit (VPD) in according to leaf positions was linearly decreased with increasing photosynthetic photon flux density (PPFD).

  • PDF

Simulation of Pervaporation Process Through Hollow Fiber Module for Treatment of Reactive Waste Stream from a Phenolic Resin Manufacturing Process (페놀수지 생산공정에서 배출되는 반응성 폐수처리를 위한 중공사막 모듈 투과증발 공정모사)

  • C. K Yeom;F. U. Baig
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.257-267
    • /
    • 2003
  • For the treatment of reactive phenolic resin waste, a simulation model of pervaporative dehydration process has been developed through hollow fiber membrane module. Some of basic parameters were determined directly from dehydration of the waste liquid through a flat sheet membrane to get realistic values. The simulation model was verified by comparing the simulated values with experimental data obtained from hollow fiber membrane module. Hollow fiber membranes with active layer coated on inside fiber were used, and feed flew through inside hollow fiber. Feed flow rate affected membrane performances and reaction by providing a corresponding temperature distribution of feed along with fiber length. Feed temperature is also a crucial factor to determine dehydration and reaction behavior by two competing ways; increasing temperature increases permeation rate as well as water formation rate. Once the permeate pressure is well below the saturated vapor pressure of feed, permeate pressure had a slightly negative effect on permeation performance by slightly reducing driving force. As the pressure approached the vapor pressure of feed, dehydration performances declined considerably due to the activity ratio of feed and permeate.

Adsorption Equilibria of Organic Solvent in an Activated Carbon Fixed Bed (활성탄 고정층에 있어서 유기용제의 흡착평형)

  • Kim, Jung-Geul;Park, Young-Hae;Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2005
  • Adsorption equilibrium data of pure solvent vapors (n-Hexane, Toluene, MEK) as well as their binary mixtures on activated carbon (sorbonorit $B_4$) were experimentally determined in the range of 293.2~323.2 K and beyond saturated vapor pressure corresponding to experimental temperature. Langmuir, Freundlich, LRC, W-VSM, FH-VSM were estimated for the predication of single component as well as binary mixtuer systems. The isosteric heat of adsorption at infinite dilution of pure n-hexane, toluene, MEK on activated carbon were 45.18, 25.85, 34.62 Kcal/mol, respectively, also, n-hexane-toluene binary adsorption of activated carbon formed an azeotrope at 293.2 K and total pressure 5.1~10.3 mmHg.

  • PDF

Prediction of flow boiling heat transfer coefficient in horizontal channels varying from conventional to small-diameter scales by genetic neural network

  • Zhang, Jing;Ma, Yichao;Wang, Mingjun;Zhang, Dalin;Qiu, Suizheng;Tian, Wenxi;Su, Guanghui
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1897-1904
    • /
    • 2019
  • Three-layer back propagation network (BPN) and genetic neural network (GNN) were developed in this study to predict the flow boiling heat transfer coefficient (HTC) in conventional and small-diameter channels. The GNN has higher precision than BPN (with root mean square errors of 17.16% and 20.50%, respectively) and other correlations. The inputs include vapor quality x, mass flux G, heat flux q, diameter D and physical parameter φ, and the predicted flow boiling HTC is set as the outputs. Influences of input parameters on the flow boiling HTC are discussed based on the trained GNN: nucleate boiling promoted by a larger saturated pressure, a larger heat flux and a smaller diameter is dominant in small channels; convective boiling improved by a larger mass flux and a larger vapor quality is more significant in conventional channels. The HTC increases with pressure both in conventional and small channels. The HTC in conventional channels rises when mass flux increases but remains almost unaffected in small channels. A larger heat flux leads to the HTC growth in small channels and an increase of HTC was observed in conventional channels at a higher vapor quality. HTC increases inversely with diameter before dry out.