• Title/Summary/Keyword: Sandwich-typed

Search Result 6, Processing Time 0.019 seconds

Acoustic Performance Improvement for Dome-typed Gymnastics Training Floor using Acoustic Simulation (음향 시뮬레이션을 이용한 돔형 체조연습장의 음향성능 개선)

  • Yun, Jae-Hyun;Jung, Chul-Woon;Kuk, Joung-Hun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.696-700
    • /
    • 2007
  • In case of dome-typed gymnastics training floor, since its form takes shape of the focus of sound, in the occasion when the finishing-material was used with the sandwich panel that prominent in reflexibility, and because the reverberation of sound in indoor is too loud, a smooth practice and teaching is very difficult. As this indoor gymnastics training floor, standing at its character, is required simultaneously the idea communication between the player and the coach, and the acoustic capability regarding to the clearness of music, besides the sport activity, the method to minimize the acoustic defect should be urgently contrived from the stages of design and beginning of construction. On this viewpoint, after investigation on the confidence of the surveyed value and the estimated value using acoustic simulation, and use of the changed finish-material, this thesis intends to design the dome-typed gymnastics training floor that secured the optimized acoustic condition. It is also considered that such result of the study could be utilized as the useful data that enables to improve the retrenchment effect of the construction cost as well as the acoustic performance, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

An in-vitro investigation of microleakage of sandwich restorations with flow able liner in class II cavaties with cervical margins in dentine

  • Lee, Kang;Hong, Chan-Ui
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.586.1-586
    • /
    • 2001
  • Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with 30-second dwell times.(omitted)

  • PDF

An analytical solution for static analysis of a simply supported moderately thick sandwich piezoelectric plate

  • Wu, Lanhe;Jiang, Zhiqing;Feng, Wenjie
    • Structural Engineering and Mechanics
    • /
    • v.17 no.5
    • /
    • pp.641-654
    • /
    • 2004
  • This paper presents a theoretic model of a smart structure, a transversely isotropic piezoelectric thick square plate constructed with three laminas, piezoelectric-elastic-piezoelectric layer, by adopting the first order shear deformation plate theory and piezoelectric theory. This model assumes that the transverse displacements through thickness are linear, and the in-plane displacements in the mid-plane of the plate are not taken to be account. By using Fourier's series expansion, an exact Navier typed analytical solution for deflection and electric potential of the simply supported smart plate is obtained. The electric boundary conditions are being grounded along four vertical edges. The external voltage and non-external voltage applied on the surfaces of piezoelectric layers are all considered. The convergence of the present approach is carefully studied. Comparison studies are also made for verifying the accuracy and the applicability of the present method. Then some new results of the electric potentials and displacements are provided. Numerical results show that the electrostatic voltage is approximately linear in the thickness direction, while parabolic in the plate in-plane directions, for both the deflection and the electric voltage. These results are very useful for distributed sensing and finite element verification.

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF