Improving the Initial Effluent Water Quality of Rapid Sand Filter by Coagulants Injection (응집제주입에 의한 급속모래여과에서 초기유출수의 수질향상)

  • Kim Woo-Hang;Jeon Ji-Hoon
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.237-242
    • /
    • 2006
  • The purpose of this research was to investigate the efficiency of coagulants dose after backwashing. The turbidity of initial effluent was high after backwashing in the rapid sand filtration and the high turbidity was almost removed by coagulants dose into filter-sand after backwashing. It was found that the turbidity of initial effluent was well removed by all kinds of the coagulants used in this study. When filtration was performed input water with differentiated pH's, the turbidity of effluent was low at the range of pH 5 - pH 7. But the removal was not good about over pH 9. This result was considered into the existence forms of aluminium, $Al(OH)^{2+}\;and\;{Al(OH)_2}^+$ at pH 5. Cryptosporidiums of effluent were 4/ml for ten minutes immediately after back washing and 3/ml until sixty minutes. However, the case of coagulant dose after backwashing, Cryptosporidiums of effluent were 0.5/ml for ten minutes with no detection after twenty minutes.

Experimental Study on Characteristics of Natural Fiber Mat (수평 천연섬유배수재의 공학적 특성 평가를 위한 실험적 연구)

  • Kim, Ju Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.2
    • /
    • pp.3-9
    • /
    • 2005
  • Natural fiber mat made with compressed coconut mat and jute filter is in the spotlight recently as an alternative material for sand mat, which is getting expensive in Korea. Tensile strength and permeability tests for the natural fiber mat were carried out to evaluate for its practical use in this study. Despite of very low tensile strength of coconut mat, that of jute filter was satisfied with conventional criteria of geotextile suggested by Christopher and Holtz(1985). Besides, permeability of fiber mat under high compressive pressure was greater than that of conventional sand material used as sand mat. It was found that the fiber mat has a great potential in substituting the conventional sand material.

  • PDF

Ammonium Ion Removal and Regeneration for Zeolite Filtration in Drinking Water Treatment (정수처리에서 제올라이트 여과를 이용한 암모니아성질소의 제거와 재생)

  • Kim, U Hyang;Lee, Seung Hui
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.661-665
    • /
    • 2004
  • As the concentration of ammonium nitrogen could be reached 2~3 mg/L in the winter in the river. It was clear that the excessive concentration of chlorinated organics could be produced with the increase of chlorine addition to remove ammonium nitrogen. In the innovative ammonium nitrogen removal process, zeolite adsorption is very efficient as substitute for rapid sand filtration without other adverse quality change in the water. This study is conducted to evaluate the feasibility of ammonium nitrogen removal and regeneration by zeolite adsorption in drinking water treatment. Also, the reuse possibility of zeolite is evaluated to change the removal efficiency of ammonium nitrogen through several times of regeneration. The ammonium nitrogen was not removed in sand filter, but it was almost removed in zeolite filter during 7 days. The sand and zeolite filters have a similar result of turbidity removal. Therefore, zeolite filtration was confirmed the removal of turbidity and ammonium nitrogen as a media. When compared KCl with NaCl as a chemical for zeolite regeneration, it is demonstrated that KCl was more efficient than NaCl in the ability of zeolite regeneration. The adsorption rate of ammonium nitrogen was almost not decreased in the results of several times of regeneration. It is indicated that both zeolite and regeneration solution were possible to reuse without variation of regeneration rate through this study.

Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment (정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과)

  • 김우항;김충환
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

Feature Extraction in an Aerial Photography of Gimnyeong Sand Dune Area by Texture Filtering

  • Chang E.M.;Park K.;Jung I.K.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.613-616
    • /
    • 2004
  • To find the best way to distinguish sand dunes from urban building and rural patches, textural analysis has been performed in Kimnyeong sand dune, Jeju. An aerial photo was re-sampled into one-meter. Homomorphic filters were applied to the original sub-scene and then high-pass filtered one. The entropy filtered one proves to be the best extraction method after high pass filtered-homomorphic filters in urban areas. The spectral values of sand dune area were similar to open land in rural area. In contrast, the texture values of sand dune area are more homogeneous than those of open land in rural area.

  • PDF

Characteristics of Inorganic Components in Fine Particles Collected at Chunchon during the Springtime Yellow Sand Occurrence Period in 2002 (춘천에서 2002년 봄철 황사 발생기간 동안에 채취된 미세분진 중 무기성분의 특성)

  • 김희갑;정경미;김동진;이종태
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.333-339
    • /
    • 2002
  • Yellow sand (YS) storms were observed about ten times in the Korean peninsula during March and April in 2002. Twenty four hour fine particle (PM$\_$2.5/) samples were collected onto the 47 mm Teflon - coated quartz filters over 9 days during and after the events using the MiniVol Portable Air Sampler at a flow rate of 5 liters per minute. The highest PM$\_$2.5/ concentration measured during the YS period was 289 $\mu\textrm{g}$/㎥, which is 13 times higher than the lowest of the values for the samples collected during the non-yellow sand period. The filter samples were analyzed for inorganic ions using the IC, AAS and Autoanalyzer, and for metals using the ICP-MS. The results showed that the concentrations of some inorganic ions (e.g., Ca$\^$2+/ and SO$_4$$\^$2-/) and metals (e.g., Fe, Mn) of soil origin were elevated during the yellow sand events.

A Study on Purification of Water Works by Multi-filter Bed Method with Aeration(Appliction of Biological Oxidation by Aerobic Microorganism) (상수 정화법에 관한 연구 (폭기식 다단여과에 의한 호기성균의 생물화학적 산화작용을 응용))

  • Chung, Yo-Han;Moon, Jae-Kyu;Jhoo, Heung-Kyu;Seo, Hwa-Jung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 1972
  • 5 bed sand filter, applying biological oxidation, was designed and studied on the treatment of water works. Never using any coagulant agent (drugs), which may cause water pollution in pre-treatment of head water, the auther attempt a high rate filtration by the microorganism (nitrofication bacteria) end plant which populate in multi layer sand beds. The result are as follows : In order to evaluate the oxygen effect on filtration, oxygen was injected in aeration tank attached to each filter tank while filtration, and $NH_3$ was tested as a representaiive ingredient. It was found out that the aeration method was more effective, with over 33% of $NH_3$ removal capacity, than the anerobic and this 5 bed filter showed double removal capacity of $NH_3$ by comparing with conventional sand bed (2 stage bed). According to the examination of two kind of head water, pre-treated with coagulant agent and activated carton, the filtration capacity was affected by the polluted condition of head water, resulting that lower value of pollution and slower velocity of filtration showed more efficiency of $NH_3$ removal. In this experiment $NH_3$ content tested in treated water had a fairly good correlation with others.

  • PDF

Purification of Animal Wastewater Using a Reed-Sand-Filter System;I. Retention Period and Seasonal Variation (갈대사상여과법(砂床濾過法)을 이용한 축산폐수정화(畜産廢水淨化);I. 처리일수(處理日數) 및 계절별(季節別) 변화(變化))

  • Lee, Deog-Bae;Kim, Jong-Gu;Kang, Jong-Goog;Kim, Sun-Kwan;So, Jae-Don;Rhee, Kyeong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.231-239
    • /
    • 1994
  • A reed-sand-filter system was used to purify swine wastewater economically. Reeds (Phragmites communis Trin) were planted on the sand / gravel bed of a 20/30cm layer depth. After the input of waste-water up to a depth of l0㎝, the effluent was monitored for pollutants on the 1st, 3rd, 5th and 7th day thereafter. As swine wastewater stayed longer, the pollutants in the effluent such as T-N, $PO_4^{3-}$, COD and BOD were removed more effectively. The sand-filter system with reeds showed a superior removal efficiency to that without reeds. Especially in summer, the former showed greater purification rates than the latter, being 30% greater in T-N, 37% in $PO_4^{3-}$, 42% in COD and 30% in suspended solids. The seasonal purification efficiency was in the decreasing order of July, October and April. Reeds took up 40.1g N, 10.8g $P_2O_5$, 38.9g $K_2O$, 2.8g CaO, 2.1g MgO per square meter of the above surface area.

  • PDF

Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment (고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

The adaptive filter configuration for down stream of Naktong river (낙동강 하류원수에 적합한 여과지의 여재구성)

  • 김상구;류동춘
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.481-488
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2~3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.