• Title/Summary/Keyword: Sand column

Search Result 226, Processing Time 0.027 seconds

A Study on Applicability of the Calculation Method for Settlement of Stone Column (쇄석말뚝의 침하량 산정방법 적용성에 관한 연구)

  • Han, Sangsoo;Jung, Suntae;Lee, Jinhyung;Kim, Bokyoung;Kim, Kyungmin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.3
    • /
    • pp.5-12
    • /
    • 2016
  • Stone column is the method that replace soft ground such as weak clay and loose sand with gravel or crushed stone which has relatively high stiffness and low compressive. Stone column increases bearing capacity of the soft ground, reduces settlement, produces ground improvement effect by consolidation drain, and is effective to prevent soil liquefaction in sandy ground during an earthquake. Stone column has been used in many civil works, and has recorded quite a lot of construction achievement internationally, but there is no standardized settlement calculation method yet. Therefore, in this study, the applicability of the existing theoretical equations were evaluated through comparison and analysis to predict a reasonable settlement of the Stone column. Consequently, Hook's law formula was verified to be the most close to numerical analysis.

Water Column Correction of Airborne Hyperspectral Image for Benthic Cover Type Classification of Coastal Area (연안 해저 피복 분류를 위한 항공 초분광영상의 수심보정)

  • Shin, Jung Il;Cho, Hyung Gab;Kim, Sung Hak;Choi, Im Ho;Jung, Kyu Kui
    • Spatial Information Research
    • /
    • v.23 no.2
    • /
    • pp.31-38
    • /
    • 2015
  • Remote sensing data is used to increasing efficiency on benthic cover type survey. Satellite and aerial imagery has variance of reflectance by water column effect even if bottom is consisted with same cover type and condition. This study tried to analyze advances of surveying extent and accuracy through water column correction of CASI-1500 hyperspectral image. Study area is coast of Gangneung city, South Korea where benthic environment is rapidly changing with bleaching of coral reef. Water column correction coefficient was estimated using regression models between water reflectance ($R_W$) and depth for sand bottom then the coefficients were applied to whole image. The results shows that expanded interpretable depth from 6-7m to 15m and decreased variation of reflectance by depth. Additionally, water column corrected reflectance image shows 13%p increased accuracy on benthic cover type classification.

영가 철로 구성된 Flow-Through Column내에서 미생물 처리에 이한 폭발성 물질의 제거 향상

  • 오병택;윤제용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.73-76
    • /
    • 2004
  • Rusted iron could retain activity to redox-sensitive pollutants in batch reactor. Flow-through columns packed with permeable reactive iron filings (Fe$^{0}$ ) between soil and sand layers were used to evaluate the applicability of bio-enhanced iron barriers to treat explosives-contaminated groundwater. One column was bioaugmented with municipal anaerobic sludge to evaluate the enhancement of biodegradation. Military contaminants (RDX, HMX, TNT, 2,4DNT, 2,6DNT), which coexist in soils at military sites, were completely removed in the bioaugmented Fe$^{0}$ layer after 8 months of operation. Overall, this research suggests that Fe$^{0}$ barriers can effectively clean up groundwater contaminated with military explosives, and that treatment efficiency can be enhanced by bioaugmentation.

  • PDF

A Prediction of Degree of Saturation using DIP and Electrical Resistivity (DIP 기법과 전기비저항을 이용한 불포화토의 포화도 예측)

  • Lim, Dong-Ki;Min, Tuk-Ki;Sin, Ho-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1177-1181
    • /
    • 2010
  • Unsaturated soil can describe soil particles, air-water and contact face between air and water. The providing a simple method to predict water content in Geotechnical mechanics is very important. In this experiment, DIP (Digital Image Processing) and electrical resistivity techniques were used simultaneously to predict the saturation degree, and the results of two techniques will be compared each other to get conclusion. The experiment was carried out for Jumunjin standard sand. The picture of experimental column of soil and water was taken at different times, then using DIP technique to measure Color number-the height of capillary in soil column. At the same time, measure electrical resistivity of the soil.

  • PDF

Development of Micro-Optical Patterned LCD-LGP using UV Inclined-Exposure Process (UV 경사노광에 의한 미세광학패턴 LCD-도광판)

  • Hwang C. J.;Kim J. S.;Ko Y. B.;Heo Y. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.51-54
    • /
    • 2005
  • Light Guide Plate (LGP) of LCD-BLU(Back Light Unit) is manufactured by forming optical pattern with $5\~100um$ in diameter on the LGP by means of sand blasting or etching method. However, in order to improve the luminance of LCD-LGP, the design of optical pattern has introduced UV inclined-exposure process in this study. This micro-optical pattern, which has asymmetric elliptical column shaped pattern, can change low viewing-angle to high viewing-angle, as well as it contribute to diffusion of light. As a result, this type of micro-optical pattern can introduce the highly luminance. The PR structure obtained in the stage of lithography has asymmetric elliptical column shape and it is processed into a micro-optical pattern. Optical design with this kind of micro-optical pattern, mold fabrication by electroplating and LGP molding with injection molding are under way.

  • PDF

Data Reduction and Analysis of the Resonant Column Testing Based on the Equation of Motion (운동방정식에 기초한 공진주 실험의 자료분석 및 해석)

  • 조성호;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.133-144
    • /
    • 2003
  • The resonant column testing is a laboratory testing method to determine the shear modulus and material damping factor of soils. The method has been widely used for many applications and its importance has increased. Since the first use of the testing method in 1960's, the low-technology electronic devices fir testing and data acquisition have limited the measurement only to the amplitude of the linear spectrum. The limitations of the testing method are also attributed to the assumption of linear-elastic material in the theory of the resonant column testing and also to the incomplete understanding of the dynamic behaviour of the resonant column testing device. Recently, Joh et al. proposed a theory to overcome the limitations of the resonant column testing by deriving the equation of motion and providing its solution for the resonant column testing device. This study proposed the improved data reduction and analysis method for the resonant column testing, thanks to the advanced data acquisition system and the new theoretical solution for the resonant column testing system. For the verification of the proposed data reduction and analysis method, the numerical simulation of the resonant column testing was performed by the finite element analysis. Also, a series of resonant column testing were performed fir Joomunjin sand, which verified the feasibility of the proposed method and revealed the limitations of the conventional data reduction and analysis method.

Mobility of silver nanoparticles (AgNPs) and oxidative degradation of endocrine disrupting chemicals by saturated column experiments (포화컬럼실험에서 산화공정을 적용한 내분비계 장애물질의 제거 및 은나노물질의 거동 연구)

  • Kim, Yejin;Heo, Jiyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.499-505
    • /
    • 2018
  • We applied column experiments to investigate the environmental fate and transport of silver nanoparticles(AgNPs) in fully saturated conditions of porous media. These column experiments were performed to emphasize oxidation method with $H_2O_2$ concentration and acidic conditions. The mobility of AgNPs was decreased with the increasing ionic strength that the surface charge of AgNPs(zeta potential) was neutralized with the presence of positive ions of $Na^+$. Additionally, it was also affected due to that not only more increased aggregated size of AgNPs and surface charge of quartz sand. The decreased breakthrough curves(BTCs) of bisphenol-A(BPA) and $17{\alpha}$-ethynylestradiol(EE2) were removed approximately 35.3 and 40%. This is due to that endocrine disrupting chemicals(EDCs) were removed with the release of $OH{\cdot}$ radicals by the fenton-like mechanisms from acidic and fenton-like reagent presenting. This results considered that higher input AgNPs with acidic conditions is proved to realistic in-situ oxidation method. Overall, it should be emphasized that a set of column experiments employed with adjusting pH and $H_2O_2$ concentration in proved to be effective method having potential ability of in-situ degradation for removing organic contaminants such as BPA and EE2.

Microbial Removal Using Layered Double Hydroxides and Iron (Hydr)oxides Immobilized on Granular Media

  • Park, Jeong-Ann;Lee, Chang-Gu;Park, Seong-Jik;Kim, Jae-Hyeon;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.149-156
    • /
    • 2010
  • The objective of this study was to investigate microbial removal using layered double hydroxides (LDHs) and iron (hydr)oxides (IHs) immobilized onto granular media. Column experiments were performed using calcium alginate beads (CA beads), LDHs entrapped in CA beads (LDH beads), quartz sand (QS), iron hydroxide-coated sand (IHCS) and hematite-coated sand (HCS). Microbial breakthrough curves were obtained by monitoring the effluent, with the percentage of microbial removal and collector efficiency then quantified from these curves. The results showed that the LDH beads were ineffective for the removal of the negatively-charged microbes (27.7% at 1 mM solution), even though the positively-charged LDHs were contained on the beads. The above could be related to the immobilization method, where LDH powders were immobilized inside CA beads with nano-sized pores (about 10 nm); therefore, micro-sized microbes (E. coli = 1.21 ${\mu}m$) could not diffuse through the pores to come into contact with the LDHs in the beads, but adhere only to the exterior surface of the beads via polymeric interaction. IHCS was the most effective in the microbial removal (86.0% at 1 mM solution), which could be attributed to the iron hydroxide coated onto the exterior surface of QS had a positive surface charge and, therefore, effectively attracted the negatively-charged microbes via electrostatic interactions. Meanwhile, HCS was far less effective (35.6% at 1 mM solution) than IHCS because the hematite coated onto the external surface of QS is a crystallized iron oxide with a negative surface charge. This study has helped to improve our knowledge on the potential application of functional granular media for microbial removal.

Analysis of Sand Compaction Piles Under Flexible Surcharge Loading (연성하중을 받는 모래다짐말뚝(SCP)의 거동분석)

  • 홍의준;김재권;정상섬;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.223-233
    • /
    • 2003
  • Sand compaction pile (SCP) is one of the ground improvement techniques which are being used for not only accelerating consolidation but also increasing bearing capacity of loose sands or soft clay grounds. In this study, laboratory model tests and 3-D finite element analyses were performed to investigate the interaction between sand compaction piles and surrounding soft soils. Based on the results obtained, as the area replacement ratio increases, the stress concentration ratio increases at the pile point, the settlement decreases, and the relative displacement between column and soil also decreases. It is also found that numerical study is illustrated by good comparison with model test results, and the numerical analysis revealed slip effects which could not be specifically identified in the model tests.

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.