• Title/Summary/Keyword: Samsung Electronic

Search Result 644, Processing Time 0.023 seconds

Adaptive RFID anti-collision scheme using collision information and m-bit identification (충돌 정보와 m-bit인식을 이용한 적응형 RFID 충돌 방지 기법)

  • Lee, Je-Yul;Shin, Jongmin;Yang, Dongmin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.1-10
    • /
    • 2013
  • RFID(Radio Frequency Identification) system is non-contact identification technology. A basic RFID system consists of a reader, and a set of tags. RFID tags can be divided into active and passive tags. Active tags with power source allows their own operation execution and passive tags are small and low-cost. So passive tags are more suitable for distribution industry than active tags. A reader processes the information receiving from tags. RFID system achieves a fast identification of multiple tags using radio frequency. RFID systems has been applied into a variety of fields such as distribution, logistics, transportation, inventory management, access control, finance and etc. To encourage the introduction of RFID systems, several problems (price, size, power consumption, security) should be resolved. In this paper, we proposed an algorithm to significantly alleviate the collision problem caused by simultaneous responses of multiple tags. In the RFID systems, in anti-collision schemes, there are three methods: probabilistic, deterministic, and hybrid. In this paper, we introduce ALOHA-based protocol as a probabilistic method, and Tree-based protocol as a deterministic one. In Aloha-based protocols, time is divided into multiple slots. Tags randomly select their own IDs and transmit it. But Aloha-based protocol cannot guarantee that all tags are identified because they are probabilistic methods. In contrast, Tree-based protocols guarantee that a reader identifies all tags within the transmission range of the reader. In Tree-based protocols, a reader sends a query, and tags respond it with their own IDs. When a reader sends a query and two or more tags respond, a collision occurs. Then the reader makes and sends a new query. Frequent collisions make the identification performance degrade. Therefore, to identify tags quickly, it is necessary to reduce collisions efficiently. Each RFID tag has an ID of 96bit EPC(Electronic Product Code). The tags in a company or manufacturer have similar tag IDs with the same prefix. Unnecessary collisions occur while identifying multiple tags using Query Tree protocol. It results in growth of query-responses and idle time, which the identification time significantly increases. To solve this problem, Collision Tree protocol and M-ary Query Tree protocol have been proposed. However, in Collision Tree protocol and Query Tree protocol, only one bit is identified during one query-response. And, when similar tag IDs exist, M-ary Query Tree Protocol generates unnecessary query-responses. In this paper, we propose Adaptive M-ary Query Tree protocol that improves the identification performance using m-bit recognition, collision information of tag IDs, and prediction technique. We compare our proposed scheme with other Tree-based protocols under the same conditions. We show that our proposed scheme outperforms others in terms of identification time and identification efficiency.

Effects of Cooking Method and Temperature on the Lipid Oxidation of Electron-Beam Irradiated Hanwoo Steak. (가열방법 및 온도가 전자선 조사한 한우 steak의 지질산화에 미치는 영향)

  • Park T. S.;Shin T. S.;Lee J. I.;Park G. B.
    • Journal of Life Science
    • /
    • v.15 no.5 s.72
    • /
    • pp.840-846
    • /
    • 2005
  • This study was carried out to investigate the effect of electron beam irradiation and cooking temperature on physico-chemical characteristics and lipid oxidation of beef. A total of six beef carcasses ($280\∼300 kg$) that were quality grade $1^{+}$(marbling score No.7, meat color No.4, maturity No.1, texture No.1) was purchased at the commercial slaughter house. The carcasses were transported and washed using high pressure water, and pasteulized with $ 50\% $ ethyl alcohol in the laboratory. After the carcasses were deboned and trimmed, loin and round were taken out to make steak (1.5cm thickness) or ground beef respectively. Samples were wrap or vacuum packaged and irradiated with 0, 3, 4.5, 6 and 7.5 kGy using electron-beam accelerator at Samsung Heavy Industries Ltd. Co. (in Taejun). Irradiated samples were cooked with different methods(electronic pan and gas oven) and temperatures ($ 60^{\circ}C, 70^{\circ}C and 80^{\circ}C$) and used to measure fatty acid composition, TBARS, cholesterol oxide products and panel test scores. The content of saturated fatty acids increased by increasing heating temperature in oven boiling steak (OBS) and pan boiling steak (PBS), and there was no difference by electron-beam irradiation. Both irradiated and non-irradiated treatment were high as the heating temperature increased in TBARS by heating temperature in PBS (p < 0.05) and the amount of Malonaldehyde (MA), standard of fat deterioration, was increased in OBS (p < 0.05). Non-irradiated and 3, 6 kGy treatment produced about 2 fold amount of MA at $ 60^{\circ}C $ compared with $ 80^{\circ}C $. In comparison with PBS, OBS produced much amount of MA and a bit different from non-irradiated treatment but did not show no tendency. As irradiation levels and heating temperature increased, the amount of cholesterol oxides products was increased and also pan-heating method, direct heating method, significantly increased the degree of oxidation compared with oven-heating method, indirect heating method (p < 0.05).

Langerhans Cell Histiocytosis in the Skull: Comparison of MR Image and Other Images (두개골의 랑게르한스 세포 조직구증: 자기공명영상과 다른 영상과의 비교)

  • Lim, Soo-Jin;Lim, Myung-Kwan;Park, Sun-Won;Kim, Jung-Eun;Kim, Ji-Hye;Kim, Deok-Hwan;Lee, Seok-Lyong;Suh, Chang-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Purpose : To evaluate the characteristic MR imaging findings of Langerhans cell histiocytosis (LCH) in the skull and to compare them with those of plain radiography and computed tomography. Materials and Methods : A total of 10 lesions in 9 patients (Age range; 5-42 years, Mean age; 18, all women) with Langerhans cell histiocytosis in the skull were included in our study. Nine lesions in nine patients were histologically confirmed by surgery or fine needle aspiration biopsy. All patients performed with MRI, and plain radiography and CT scan were done in 7 patients (8 lesions). Two experienced neuroradiologists reviewed the radiological examinations independently with attention to location, size, shape and nature of the lesions in the skull and compared the extent and extension of the lesions to adjacent structures. Results : The lesions were distributed in all of the skulls without predilection site. On MRI, the masses were shown as well-enhancing soft tissue masses (10/10) mainly in diploic spaces (8/10) with extension to scalp (9/10) and dura mater (7/10). Dural enhancement (7/10) and thickening (4/10) were seen. The largest diameter of the soft tissue masses ranged 1.1 cm to 6.8 cm, shaped as round (5/10) or oval (5/10). On CT scans, the lesions were presented as soft tissue masses involving diploic space (6/8) and scalp extension (7/8) were also well visualized. Although bony erosion or destruction was more clearly seen on CT rather than those of MRI, enhancement of soft tissue masses and dura were not well visualized on CT. In contrast, all of the lesions in LCH were seen as punched out (4/8), beveled-edge appearance (4/8) osteolytic masses in plain radiography, but scalp and dural extension could not be seen. Conclusion : Characteristic MR findings in patients with LCH are soft tissue mass in diploic space with extension to dura and scalp, and MRI would be better imaging modality than plain radiography or CT.

  • PDF

Clinical Outcomes of Ultrasound-Guided Transmeniscal Injection in Medial Compartment Knee Osteoarthritis (무릎 내측 구획 골관절염에서 초음파 유도하 경 반월상 연골 주사의 임상적 효과)

  • Jung, Eui Yub;Wang, Joon Ho;Lee, Eui-Sub;Lee, Sung-Sahn;So, Sang-Yeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.418-425
    • /
    • 2020
  • Purpose: The purpose of this study was to introduce the ultrasound-guided transmeniscal injection in medial compartment knee osteoarthritis and analyze the clinical outcomes. Materials and Methods: The electronic medical records of 36 patients with medial compartment knee osteoarthritis who were treated with an ultrasound-guided transmeniscal injection from March 2019 to July 2019 were accessed for this retrospective review. Using an ultrasound guided spinal needle, the patients received an intra-articular steroid injection at the medial compartment of the knee. A physical examination was conducted at the initial visit (pre-injection), and at one week, four weeks, and eight weeks after the injection. The numeric pain rating scale (NRS), Lequesne index, and Western Ontario and McMaster Universities Osteoarthritis (WOMAC) score were measured at each visit and analyzed over time. The percentage change of the patients who revealed substantial improvement was analyzed. The NRS, Lequesne index, and percentage of patients, who revealed substantial improvement over time classified by osteoarthritis grade, were analyzed. Results: The NRS and Lequesne index decreased at one week, four weeks, and eight weeks after the injection compared to the initial baseline, and the pain-relief effect continued without change until eight weeks. The percentage of patients who showed substantial improvement at one, four, and eight weeks was 50.0%, 47.2%, and 52.8%, respectively. The WOMAC scores decreased at one, four, and eight weeks compared to the initial baseline, and the decrease was continued without any difference until eight weeks. The percentage of patients with osteoarthritis stage 1 or 2 who revealed more than substantial improvement was significantly higher at one, four, and eight weeks than those with osteoarthritis stages 3 or 4 (p<0.05). Conclusion: In patients with medial compartment knee osteoarthritis, the pain reduction and functional improvement persisted for at least eight weeks after the ultrasound-guided transmeniscal injection at the medial compartment. In particular, patients with medial compartment osteoarthritis stage 1 or 2 showed more effective pain reduction.