• Title/Summary/Keyword: Sampling volume

Search Result 342, Processing Time 0.032 seconds

An Evaluation of Sampling Design for Estimating an Epidemiologic Volume of Diabetes and for Assessing Present Status of Its Control in Korea (우리나라 당뇨병의 역학적 규모와 당뇨병 관리현황 파악을 위한 표본설계의 평가)

  • Lee, Ji-Sung;Kim, Jai-Yong;Baik, Sei-Hyun;Park, Ie-Byung;Lee, June-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.2
    • /
    • pp.135-142
    • /
    • 2009
  • Objectives : An appropriate sampling strategy for estimating an epidemiologic volume of diabetes has been evaluated through a simulation. Methods : We analyzed about 250 million medical insurance claims data submitted to the Health Insurance Review & Assessment Service with diabetes as principal or subsequent diagnoses, more than or equal to once per year, in 2003. The database was re-constructed to a 'patient-hospital profile' that had 3,676,164 cases, and then to a 'patient profile' that consisted of 2,412,082 observations. The patient profile data was then used to test the validity of a proposed sampling frame and methods of sampling to develop diabetic-related epidemiologic indices. Results : Simulation study showed that a use of a stratified two-stage cluster sampling design with a total sample size of 4,000 will provide an estimate of 57.04%(95% prediction range, 49.83 - 64.24%) for a treatment prescription rate of diabetes. The proposed sampling design consists, at first, stratifying the area of the nation into "metropolitan/city/county" and the types of hospital into "tertiary/secondary/primary/clinic" with a proportion of 5:10:10:75. Hospitals were then randomly selected within the strata as a primary sampling unit, followed by a random selection of patients within the hospitals as a secondly sampling unit. The difference between the estimate and the parameter value was projected to be less than 0.3%. Conclusions : The sampling scheme proposed will be applied to a subsequent nationwide field survey not only for estimating the epidemiologic volume of diabetes but also for assessing the present status of nationwide diabetes control.

A Study on the Stand Volume Estimation by Strand Method (Strand법(法)에 의한 임분재적추정(林分材積推定)에 관(關)한 연구(硏究))

  • Lee, Heung Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.2
    • /
    • pp.187-192
    • /
    • 1991
  • This study was carried out to estimate the stand volume for Japanese larch(Larix leptolepis) by Strand sampling method. The data collected for this study were based on the 380 sample plots from the field survey, which were distributed in the major part of Korea(Kyeongi, Kangweon, Chungbuk, Chungnam, Chunbuk and Kyeongbuki), and the plotless sampling instrument such as dendrometer, spiegel relascope and tele-relascope were used. The procedure for this study is summarized briefly as follows : 1. There were not only significant differences between volume estimation by Strand sampling method and that by plot survey method, and the relationship was y=bx, where b approached nearly 1. Therefore, the stand volume of Japanese larch could by estimated by Strand sampling method. 2. The value measured by three different plotless sampling instruments did not showed any significant differences between instruments and observers, density and instruments, and ground slope and instruments. 3. With the stand volume, basal area height showed the highest correlation and stand form height, average height, basal area per ha correlated with the volume in thier orders. 4. The best fitted equation of stand volume estimation with basal area height by relascope was as follow. log V=-0.0375+0.8910 log GH-1.5946 1/GH Stand volume table also was obtained using the above estimeated equation. 5. The relationship between estimated value and actual value was Y=bx, where b was nearly 1. The correlation coefficient was very high and the percentage of estimated error was 4.5%.

  • PDF

A Probabilistic Sampling Method for Efficient Flow-based Analysis

  • Jadidi, Zahra;Muthukkumarasamy, Vallipuram;Sithirasenan, Elankayer;Singh, Kalvinder
    • Journal of Communications and Networks
    • /
    • v.18 no.5
    • /
    • pp.818-825
    • /
    • 2016
  • Network management and anomaly detection are challenges in high-speed networks due to the high volume of packets that has to be analysed. Flow-based analysis is a scalable method which reduces the high volume of network traffic by dividing it into flows. As sampling methods are extensively used in flow generators such as NetFlow, the impact of sampling on the performance of flow-based analysis needs to be investigated. Monitoring using sampled traffic is a well-studied research area, however, the impact of sampling on flow-based anomaly detection is a poorly researched area. This paper investigates flow sampling methods and shows that these methods have negative impact on flow-based anomaly detection. Therefore, we propose an efficient probabilistic flow sampling method that can preserve flow traffic distribution. The proposed sampling method takes into account two flow features: Destination IP address and octet. The destination IP addresses are sampled based on the number of received bytes. Our method provides efficient sampled traffic which has the required traffic features for both flow-based anomaly detection and monitoring. The proposed sampling method is evaluated using a number of generated flow-based datasets. The results show improvement in preserved malicious flows.

A Design and Implementation of Volume Rendering Program based on 3D Sampling (3차원 샘플링에 기만을 둔 볼륨랜더링 프로그램의 설계 및 구현)

  • 박재영;이병일;최흥국
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.5
    • /
    • pp.494-504
    • /
    • 2002
  • Volume rendering is a method of displaying volumetric data as a sequence two-dimensional image. Because this algorithm has an advantage of visualizing structures within objects, it has recently been used to analyze medical images i.e, MRI, PET, and SPECT. In this paper. we suggested a method for creating images easily from sampled volumetric data and applied the interpolation method to medical images. Additionally, we implemented and applied two kinds of interpolation methods to improve the image quality, linear interpolation and cubic interpolation at the sampling stage. Subsequently, we compared the results of volume rendered data using a transfer function. We anticipate a significant contribution to diagnosis through image reconstruction using a volumetric data set, because volume rendering techniques of medical images are the result of 3-dimensional data.

  • PDF

Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling (혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향)

  • Yang, Hyeok Syng;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

Evaluation of Methodology for the Measurement of VOCs in the Air by Adsorbent Sampling and Thermal Desorption with GC Analysis (흡착포집 및 열탈착/GC 분석에 의한 공기 중 휘발성 유기화합물의 측정방법론 평가)

  • 백성옥;황승만;박상곤;전선주;김병주;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.121-138
    • /
    • 1999
  • This study was carried out to evaluate the performance of a sampling and analytical methodology for the measurement of selected volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/FID and GC/MSD analysis. Target analytes were aromatic VOCs, including BTEX, 1,3,5-and 1,2,4,-trimethylbenzenes(TMBs), and naphthalene. The methodology was investigatedwith a wide range of performance criteria such as repeatability, linearity, lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal and external standards. standards. Stability of samples collected on adsorbent tubes during storage was also investigated. In addition, the sampling and analytical method developed during this study was applied to real samples duplicately collected in various indoor and outdoor environments. Precisions for the duplicate samples and distributed volume samples appeared to be well comparable with the performance criteria recommended by USEPA TO-17. The audit accuracy was estimated by inter-lab comparison of both duplicate samples and standard materials between the two independent labs. The overall precision and accuracy of the method were estimated to be within 30% for major aromatic VOCs such as BTEX. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

  • PDF

A study on Pb, Zn and Fe Concentrations of Ambient Air Adjacent to Heavy Traffic Road Side in Seoul (서울시 주요 도로변 대기중 납, 아연 및 철 농도에 관한 조사연구)

  • 조준호;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.110-117
    • /
    • 1998
  • This study was carried out to investigate the concentrations of TSP, Pb, Zn and Fe in ambient air adjacent to the heavy traffic road side in Seoul from October 1 to October 31, 1997. The results were as follows 1. The concentrations of TSP were 260 $\mu g/m^3$, 184 $\mu g/m^3$, 147 $\mu g/m^3$ in Chongro, Chungkechun and Kangnam-terminal, respectively. The concentration of TSP was correlated with the traffic volume of the sampling sites (r=0.77). 2. The concentrations of Pb were 638 ng/m$^3$, 335 ng/m$^3$, 233 ng/m$^3$ in Chungkechun, Kangnam-terminal and Chongro, respectively. The concentration of Pb was correlated with the Truck (over 1.4 ton) volume of the sampling sites (r=0.71). The Pb contents among these sites were significantly different (p < 0.05). 3. The concentrations of Zn were 535 ng/m$^3$, 461 ng/m$^3$, 439 ng/m$^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Zn was badly correlated with the traffic volume of the sampling sites (r=0.23). 4. The concentrations of Fe were 5.32 $\mu g/m^3$, 4.51 $\mu g/m^3$ and 3.18 $\mu g/m^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Fe was correlated with the traffic volume of the sampling sites (r=0.83). The Fe contents among these sites were significantly different (p < 0.05). 5. The concentrations of TSP, Pb, Zn, Fe investigated didn't exceed the Korean Ambient Air Quality Standards, but more researches in relation to these will be required in considering people working in these sites suffered from cough, asthma and chronic headache.

  • PDF

Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

Standardization of Sample Handling Methods to Reduce the Rate of Inadequate Sampling

  • Yo-Han Seo
    • Quality Improvement in Health Care
    • /
    • v.29 no.2
    • /
    • pp.85-93
    • /
    • 2023
  • Purpose: The predominant approach for mitigating inadequate sampling rates has primarily involved bolstering the volume of education. This study aimed to curtail inadequate sampling rates through the implementation of continuous quality improvement (CQI) activities, tailoring effective methods to the unique needs of each institution. Methods: We developed a sample handling guidebook and implemented QI activities to address this issue. Results: These measures resulted in a 4.7% decrease in inadequate sampling rates, concurrently improving knowledge of sample handling and overall nurse satisfaction. We addressed the root causes of inadequate sampling before laboratory pre-processing by: 1) focusing on systematic rather than erratic errors through CQI activities, 2) revising the sample handling guide, and 3) delivering face-to-face education based on the specific needs of the nursing department. These changes resulted in an additional 0.6% decrease in the inadequate sampling rate. Conclusion: This study demonstrates that the implementation of CQI activities based on evidence derived from a multifaceted causal analysis significantly reduced the inadequate sampling rate compared to previous studies.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF