• Title/Summary/Keyword: Sampling method

Search Result 4,948, Processing Time 0.03 seconds

Improvement of Verification Method for Remedial Works through the Suggestion of Indicative Parameters and Sampling Method (정화 보조지표와 시료 채취 방법 제안을 통한 토양정화검증 제도 개선 연구)

  • Kwon, Ji Cheol;Lee, Goontaek;Kim, Tae Seung;Yoon, Jeong-Ki;Kim, Ji-in;Kim, Yonghoon;Kim, Joonyoung;Choi, Jeongmin
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.179-191
    • /
    • 2016
  • In addition to the measurement of the concentration of soil contaminants, the new idea of indicative parameters was proposed to validate the remedial works through the monitoring for the changes of soil characteristics after applying the clean up technologies. The parameters like CFU (colony forming unit), pH and soil texture were recommended as indicative parameters for land farming. In case of soil washing, water content and the particle size distribution of the sludge were recommended as indicative parameters. The sludge is produced through the particle separation process in soil washing and it is usually treated as a waste. The parameters like water content, organic matter content, CEC (cation exchange capacity) and CFU were recommended as indicative parameters for the low temperature thermal desorption method. Besides the indicative parameter, sampling methods in stock pile and the optimal minimum amount of composite soil sample were proposed. The rates of sampling error in regular grid, zigzag, four bearing, random grid methods were 17.3%, 17.6%, 17.2% and 16.5% respectively. The random grid method showed the minimum sampling error among the 4 kinds of sampling methods although the differences in sampling errors were very little. Therefore the random grid method was recommended as an appropriate sampling method in stock pile. It was not possible to propose a value of optimal minimum amount of composite soil sample based on the real analytical data due to the dynamic variation of $CV_{fund{\cdot}error}$. Instead of this, 355 g of soil was recommended for the optimal minimum amount of composite soil sample under the assumption of ISO 10381-8.

A Study for Time Standard Estimation with Activity Sampling Method (가동샘플링기법에 의한 표준시간추정에 관한 연구)

  • 이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.9
    • /
    • pp.1-5
    • /
    • 1983
  • This study takes over the application of survey sampling theory to activity sampling and the application of activity sampling to time standard estimation. Cluster, stratified, and multistage sampling are studied in conjunction with random and systematic sampling. Estimation procedures that will maximize the information obtained per cost expended on the study and specification of the procedure to be used to estimate the accuracy of the estimates for the adopted procedure are considered. The use of multiple regression md linear programming to estimate standard element performance time from typical job lot production data is also considered.

  • PDF

An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR (비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구)

  • Kim, Woo-Seok;Shon, Deok-Young;Park, Young-Moo;Yoo, Jae-Suk;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

Monitoring Benthic AIgal Communides:A Comparison of Targeted and Coefficient Sampling Methods

  • Edwards, Matthew S.;Tinker, Martin T.
    • ALGAE
    • /
    • v.24 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • Choosing an appropriate sample unit is a fundamental decision in the design of ecological studies. While numer-ous methods have been developed to estimate organism abundance, they differ in cost, accuracy and precision.Using both field data and computer simulation modeling, we evaluated the costs and benefits associated with twomethods commonly used to sample benthic organisms in temperatc kelp forests. One of these methods, theTargeted Sampling method, relies on different sample units, each "targeted" for a specific species or group ofspecies while the other method relies on coefficients that represent ranges of bottom cover obtained from visual esti-mates within standardized sample units. Both the field data and the computer simulations suggest that both meth-ods yield remarkably similar estimates of organisnm abundance and among-site variability, although the Coefficientmethod slightly underestimates variability armong sample units when abundances are low. In contrast, the twomethods differ considerably in the effort needed to sample these communities; the Targeted Sampling requiresmore time and twice the persormel to complete. We conclude that the Coeffident Sampling metliod may be bettcrfor environmental monitoring programs where changes in mean abundance are of central conccm and resources arelimiting, but that the Targeted sampling methods may be better for ecological studies where quantitative reIation-ships among species and small-scale variability in abundance are of central concern.

Preparation and Consideration of Sample Collection in Undeclared Areas for Denuclearization Verification

  • Kim, Dong Yeong;Kim, Giyoon;Lee, Jun;Lim, Kyung Taek;Chung, Heejun;Seo, Jihye;Kim, Myungsoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.4
    • /
    • pp.479-489
    • /
    • 2021
  • The Republic of Korea is expected to participate in the denuclearization verification activities by the International Atomic Energy Agency (IAEA) in case any neighboring countries declared denuclearization. In this study, samples for the verification of nuclear activities in undeclared areas were selected for the denuclearization of neighboring countries, and the appropriateness of the procedures was considered. If a country with nuclear weapons declares denuclearization, it must be accompanied by the IAEA's verification regarding nuclear materials and weapons in the declared and undeclared areas. The analysis of the process samples or on-site environmental samples and the verification of undeclared nuclear facilities and materials aid in uncovering any evidence of concealment of nuclear activity in undeclared areas. Therefore, a methodology was established for effective sampling and analysis in accordance with proper procedures. Preparations for sampling in undeclared areas were undertaken for various potential scenarios, such as, the establishment of zones according to radiation dose, methods of supplying electricity, wireless communication networks, targets of sampling according to characteristics of nuclides, manned sampling method, and unmanned sampling method. Through this, procedures were established for pre- and post-site settings in preparation for hazards and limiting factors at nuclear inspection sites.

Hybrid Down-Sampling Method of Depth Map Based on Moving Objects (움직임 객체 기반의 하이브리드 깊이 맵 다운샘플링 기법)

  • Kim, Tae-Woo;Kim, Jung Hun;Park, Myung Woo;Shin, Jitae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.11
    • /
    • pp.918-926
    • /
    • 2012
  • In 3D video transmission, a depth map being used for depth image based rendering (DIBR) is generally compressed by reducing resolution for coding efficiency. Errors in resolution reduction are recovered by an appropriate up-sampling method after decoding. However, most previous works only focus on up-sampling techniques to reduce errors. In this paper, we propose a novel down-sampling technique of depth map that applies different down-sampling rates on moving objects and background in order to enhance human perceptual quality. Experimental results demonstrate that the proposed scheme provides both higher visual quality and peak signal-to-noise ratio (PSNR). Also, our method is compatible with other up-sampling techniques.

Enhanced Coulomb Counting Method for State-of-Charge Estimation of Lithium-ion Batteries based on Peukert's Law and Coulombic Efficiency

  • Xie, Jiale;Ma, Jiachen;Bai, Kun
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.910-922
    • /
    • 2018
  • Conventional battery state-of-charge (SoC) estimation methods either involve sophisticated models or consume considerable computational resource. This study constructs an enhanced coulomb counting method (Ah method) for the SoC estimation of lithium-ion batteries (LiBs) by expanding the Peukert equation for the discharging process and incorporating the Coulombic efficiency for the charging process. Both the rate- and temperature-dependence of battery capacity are encompassed. An SoC mapping approach is also devised for initial SoC determination and Ah method correction. The charge counting performance at different sampling frequencies is analyzed experimentally and theoretically. To achieve a favorable compromise between sampling frequency and accumulation accuracy, a frequency-adjustable current sampling solution is developed. Experiments under the augmented urban dynamometer driving schedule cycles at different temperatures are conducted on two LiBs of different chemistries. Results verify the effectiveness and generalization ability of the proposed SoC estimation method.

An Algorithm of Minimum Bandpass Sampling Selection with Guard-band Between Down-converted Adjacent IF signals (하향변환된 인접 IF신호간의 보호대역을 고려한 최소 대역통과 샘플링 주파수 선택 알고리즘)

  • Bae, Jung-Hwa;Cho, Jae-Wan;Ko, Yong-Chae;Cac, Tran Nguyen;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1286-1295
    • /
    • 2007
  • This paper proposes, based on a bandpass sampling theory, a novel method to find valid sampling frequency range and minimum sampling rate with low computational complexity for downconversion of N bandpass radio frequency(RF) signals, under application of all possible signal placements(full permutations) in a IF stage. Additionally, we have developed a complexity-reducing method to obtaine the opttimal and minimal sampling rate for supporting the user-wanted guard-band or spacing between adjacent downconverted signal spectrums. Moreover, we have verified through comparisons with other methods that the proposed methods have more advantageous properties.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

A Comparison of PPS and Simple Cluster Sampling in Large Scale Sampling -Based on Economically Active Population Survey Sample Design (대규모 표본설계에서 확률비례 및 단순집락추출법 비교 -경제활동인구 표본조사 사례를 중심으로-)

  • 윤연옥;이상은
    • The Korean Journal of Applied Statistics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • In PPS sampling, measure of size(MOS) is used to determine the probability of selection of sampling unit. However, some large scale surveys conducted in NSO(National Statistical Office) showed that the sampling units have the similar MOS. In such case, simple cluster sampling method instead of PPS sampling is recommended to give the interviewers a similar work load. In this paper, MSE and CV of the above two sampling methods applied to the 1997 Economically Active Population Survey sample design are compared.

  • PDF