• 제목/요약/키워드: Sampling Device

Search Result 273, Processing Time 0.027 seconds

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Research on fault analysis and reliability improvement of APU start motor for Korea Utility Helicopter (한국형 기동헬기 APU 시동모터 결함원인 분석 및 신뢰성 개선)

  • Kang, Tae-Woo;Yeom, Hyo-Won;Lee, Hee-Rang;Ahn, Jong-Moo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.703-709
    • /
    • 2017
  • Korea Utility Helicopter(KUH) is a project to replace the aging helicopter presently being operated by the military with a domestic helicopter. The auxiliary power unit is a device that supplies emergency power to the system by an alternator installed when the main generator fails and the start motor converts the electrical energy of the battery into mechanical rotational energy to rotate the auxiliary power unit engine. With continuing power and operation, defects of the starting motor were found and improvements were carried out to solve it. In the failure mode analysis, the causes of possible defects were classified into 5 categories. Analysis of the 5 factors revealed that the main cause of defects is mechanical wear, which was found to be related to spring pressure. 250 tests were conducted through the theoretically determined pressure and regression analysis was performed with 4 sampling.The results showed that pressure was related to wear rate. In conclusion, early wear and breakage due to wear can be controlled through spring force and test showed the prediction of wear and the validity of the result were confirmed.

Perception and Attitude on Augmented Reality Smart Glass for Healthcare Convergence Simulation (증강현실(AR) 스마트글라스 보건의료 융합 시뮬레이션에 대한 인식 및 태도)

  • Lee, Youngho;Choi, Jongmyung;Yoon, Hyoseok;Kim, Sun Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.369-377
    • /
    • 2021
  • Augmented reality smart-glass enables healthcare providers to use patient and their care related information without interference of workflow. In addition, augmented reality smart-glass simulation had advantages in improving competency via remote collaboration and real-time information sharing. This study investigated perception and attitude regarding augmented reality smart glass based healthcare simulation on three different groups of healthcare major students, computer major students, developers and faculties. Using convenience sampling method, data were obtained from 95 participants and statistical analysis were performed using SPSS 25.0. Developer and faculty group showed the highest scores, followed by healthcare major students. There was the high expectation on augmented reality smart-glass for skill acquisition and the high performance and big screen were essential features of device. The findings of this study revealed that differences between healthcare and computer major students exist and strategies to reduce those gaps are required to adopt augmented reality smart glass in healthcare settings.

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

Development of Thickness Measurement Method From Concrete Slab Using Ground Penetrating Radar (GPR 기반 콘크리트 슬래브 시공 두께 검측 기법 개발)

  • Lee, Taemin;Kang, Minju;Choi, Minseo;Jung, Sun-Eung;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.39-47
    • /
    • 2022
  • In this paper, we proposed a thickness measurement method of concrete slab using GPR, and the verification of the suggested algorithm was carried out through real-scale experiment. The thickness measurement algorithm developed in this study is to set the relative dielectric constant based on the unique shape of parabola, and time series data can be converted to thickness information. GPR scanning were conducted in four types of slab structure for noise reduction, including finishing mortar, autoclaved lightweight concrete, and noise damping layer. The thickness obtained by GPR was compared with Boring data, and the average error was 1.95 mm. In order to investigate the effect of finishing materials on the slab, additional three types of finishing materials were placed, and the following average error was 1.70 mm. In addition, sampling interval from device, the effect of radius on the shape of parabola, and Boring error were comprehensively discussed. Based on the experimental verification, GPR scanning and the suggested algorithm have a great potential that they can be applied to the thickness measurement of finishing mortar from concrete slab with high accuracy.

Analysis of Solute Transport based on Electrical Resistance Measurements from Laboratory Column Tests (전기저항센서가 부착된 주상실험기에서 측정된 전기저항값을 이용한 용질의 이동해석)

  • Kim, Yong-Sung;Kim, Jae-Jin;Park, Junboum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.231-238
    • /
    • 2008
  • A column testing device capable of measuring the electrical resistivity of soil at 3 different locations was developed to verify applicability of bulk electrical conductivity (BEC) breakthrough curves in monitoring contaminant transport. Tracer injection tests were conducted with three different types of saturated sands to obtain average linear velocities and longitudinal hydrodynamic dispersion coefficients based on BEC breakthrough curves and effluent solute breakthrough curves. Comparative analysis of transport parameters obtained from curve fitting the results into the analytical solutions confirmed the validity of resistance measurements in estimating time-continuous resident solute concentration. Under the assumption that a linear relationship exists between ${\sigma}_{sat}-{\sigma}_w-C$, the BEC breakthrough curves are able to effectively reduce the laborious and time-consuming processes involved in the conventional method of sampling and analysis. In order to reduce possible uncertainties in analyzing the BEC breakthrough curves, it was recommended that resistance measurements take place nearby the effluent boundary. In addition, a sufficient electrical contrast or difference in the electrical conductivity of the influent and the saturating solution is required to conduct reliable analysis.

In-Situ Gamma Spectrometry Research Analysis and Radiation Efficiency Sensitivity Evaluation (감마핵종 In-Situ 측정 연구 동향 분석 및 방사능 측정 효율 민감도 평가)

  • Hyun Jun Na;Hyeok Jae Kim;Seong Yeon Lee;Min Woo Kwak;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Since a large amount of radioactive waste is expected to be generated due to permanent shutdown of many nuclear power plants, it is necessary to prepare efficient management methods for radioactive waste. Therefore, there is a need for a based study to apply the In-Situ gamma spectrometry, which can simplify the measurement procedure. The purpose of this study is to analyze research cases of In-Situ gamma spectrometry and to analyze the sensitivity of measurement according to influencing factors on In-Situ gamma spectrometry. Research cases of five institutions, including the CERN and the Imperial College Reactor Centre (ICRC), were selected as the institutions to be investigated. Research on the In-Situ gamma spectrometry was conducted on the satisfaction of the acceptance criteria for radioactive waste and the analysis of residual radioactivity in the site. In-Situ Objective Counting System (ISOCS) was used as a major measuring device. Sampling and computer code were used to verify the analysis results. For evaluation of measuring sensitivity according to influencing factors on In-Situ gamma spectrometry, the thickness of the measurement target, the distance between the detector and the target, the angle of the collimator, and the contamination location were performed using ISOCS's Geometry Composer. In every case, based on 122 keV, the efficiency decreased as the energy increased in the high energy region, and the efficiency decreased as the energy decreased in the low energy region. As the target thickness increased, the efficiency decreased, and as the distance between target and detector increased, the efficiency decreased. As the distance between contamination and detector increased, the efficiency decreased, and as the angle of the collimator increased, the measurement efficiency increased. However, when simulating the measurement situation using Geometry Composer, the background is not considered, and the probability of incident in the background increases as the angle increases, so further research needs to be conducted in consideration of these. This study can be utilized when applying the In-Situ gamma spectrometry of radioactive waste clearance in the future.

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

A Study of Health Condion and Shift Service of the Nurse in (종합병원 간호사의 교대근무와 건강상태에 관한 연구)

  • Kim, Soon-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.119-133
    • /
    • 1997
  • Continuing shift service of clinical nurses can be not only the cause of occupational dissatisfaction by being connected with the change of circadian rhythm and the burden of duties to be applicable to such changes. But also of inviting the lowering of nursing quality by being affected to the resignation of the nurses as the threat to the health of the nurses. This study has selected 500 nurses at random under non-probability sampling who have been serving by shift in 7 general hospitals which have over 400 sickbeds for the purpose of cross-sectional survey design from Sep. 7 through 20, 1996. Standardized modification of the CMI has been used which was designed for Koreans with Cornell Medical Index developed by Broadman and his fellow workers as the study device. The structure of the device was composed of 35 questions on physical appeal(Chronbach's ${\alpha}=8507$) and 22 questions of mental appeal(Cronbach's ${\alpha}=.8166$ totalling 57 questions. The collected data has been computerrized by using SPSS. General character, present symptom, perceived symptom and others are sought by practical number and percentage, and the health condition comparison followed by general characters was conducted by t-test and ANOVA. The post test was by Duncan's test by the level of p<.05. 1) The items of the answer that they have the physical symptom presently by 50% or over of the nurses were as "Do you often have spells of severe dizziness", "Are your eyes often red or inflamed", "Does press or pain in the head often make like miserable", "Are your ankles often badly swollen", "Do pains in the back make it hard for you to keep up with your work". 2) The items of the answer by over 50% of the nurses as the mental symptom at present were "do you fell bad when criticized?", "Do you get angry when everything is against your will?", "do you get angry when ordered to do this and that?", "do you feel uneasy by such a trifle thing?", "do you tremble or are you freightened by sudden sound?". The mental and physical symptoms which have appeared presently in connection with the shift service have been agreed with each other. But the physical condition has been worse than the mental one. 3) In the physical health conditions followed by demosociological character, there were the significant differences by sex, religion and place of residence(p<.05), and in the mental health conditions, there were the significant differences by age, marital status, residence place and the required time for attending hospital(p<.05). 4) There was significant difference by the degree of satisfaction about the duty in both the physical and mental health conditions. In short, the higher the degree of duty satisfaction, the better the health conditions. 5) There were the significant difference according to the times of night duty and whether they take the drug or not or the kinds of the drugs in the physical health conditions related with the characters of night shift. Mental health conditions in the night shift case showed significant differences according to their taking drug or not or the kinds of the drugs(p<.05). I can confirm that the nurses have been affected continuously by the shift service mentally and physically. The maintenance of the physical and mental health of the nurses and its promotion are very important problem to guarantee the quality nursing in the performance of the nursing service continuously and effectively, so the hospital should make every effort to improve the duty conditions by finding out the causes affecting to their health. In the nursing management viewpoint, I think that elevating the satisfaction degree about the duty would be a great help to the promotion of physical and mental health conditions. But what is most important is that the nurses themselves should take care of themselves in maintaining the good conditions in their service in the hospital.

  • PDF

Influence of Subjective Oral Health Interest and Recognition in Academic Boys' High School Students upon Oral Health Practice in Some Regions (일부지역 인문계 남자고등학생의 주관적 구강건강관심도와 인지도가 구강건강실천에 미치는 영향)

  • Lee, Hyun-Ok;Chun, Ju-Yean
    • Journal of dental hygiene science
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • The purpose of this study was to offer information in order to induce and practice forming right oral health habit by grasping oral health practice according to subjective oral health interest and recognition in Academic Boys' High School students. Targeting students of Academic Boys' High School where is located in Jeollabuk-do from May 20, 2010 to June 20, the self-administered questionnaire survey was carried out by convenience sampling. The following are the results that the collected data was carried out statistical analysis by using SPSS 12.0 program. 1. Among factors of oral health practice according to oral health interest level, toothbrushing was the highest with 3.89 points. It was in order of education and interest with 3.18 points, diet control with 2.93 points, a regular visit with 2.69 points, and the practice of oral hygiene device with 2.12 points. 2. Among factors of oral health practice according to subjective oral health recognition level, toothbrushing was the highest with 3.89 points. It was in order of education and interest with 3.17 points, diet control with 2.93 points, a regular visit with 2.69 points, and the practice of oral hygiene device with 2.12 points. 3. In correlation between subjective oral health recognition level and oral health practice factor, the more recognition of being healthy in the subjective oral health recognition level led to the higher oral health practice level(p<0.01). 4. As for influence of oral health practice factor upon subjective oral health recognition level, the subjective oral health recognition was high in a group of practicing toothbrushing(p<0.01) and of visiting dental clinic regularly(p<0.05).