• 제목/요약/키워드: Sampling Device

검색결과 273건 처리시간 0.027초

하악 전치부의 개폐운동과 안정위에 관한 연구 (A Study on Mandibular Opening and Closing Movements at Mandibular incisor region and Clinical Rest Position)

  • 안승근;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 1989
  • The purpose of this study was to investigate the mandibular opening and closing movements at mandibular incisor region and clinical rest position in normal subject using the newly developed electric mandibular movement analyzing device, (M.K.G.-K6 diagnostic system, Myo-tronics Inc. Seattle, WA, U.S.A.) The 58 normal subjects, who were students of the College of Dentistry, Chonbuk National University, were selected according to sampling criteria. The obtained results were as follows: 1. There was no significant difference of distribution of opening and closing movement patterns at mandibular incisor region between male and female. There was significant difference between habitual and maximum movement patterns both in sagittal and frontal plane. 2. Although the percentage of distribution of crossover pattern was highest in all cases, but there were significant differences between patterns only at habitual opening and closing movement in sagittal plane. 3. The mean of maximum opening was $47.29{\pm}4.68mm$ in male and $42.15{\pm}4.95mm$ in female. Therefore the mean of maximum opening was larger in male than in female. 4. The mean of maximum laterotrusion in frontal trajectory was larger to the left than to the right. Also the proportion of left deviation at maximum opening position was larger than that of other cases. 5. The mean of maximum opening and closing velocity was higher in male than in female and the mean of closing velocity was higher than that of opening velocity. Also the amount of separation from the centric occlusion was higher in maximum closing velocity than in maximum opening velocity. 6. Clinical rest position was $1.70{\pm}0.99mm$ inferior, $0.74{\pm}0.57mm$ anterior, $0.99{\pm}0.51mm$ right from centric occlusion and the A/V ratio was 1:2.7.

  • PDF

Pulsed DC Power Magnetron Sputter System을 사용한 Copper 박막 특성 조절 (Control of Copper Thin Film Characteristics by using Pulsed DC Power Magnetron Sputter System)

  • 김도한;이수정;김태형;이원오;염원균;김경남;염근영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.107-107
    • /
    • 2017
  • 전자제품의 성능이 향상됨에 따라서 전자제품에 사용되는 부품의 고집적화가 필연적으로 요구되고 있으며, 고집적화 된 전자제품의 방열(heat dissipation)에 관한 문제점이 대두되고 있다. 방열은 전자기기의 성능과 수명을 유지하는데 있어서 중요한 문제 중 하나로서 방열 효과를 높이기 위해 다양한 연구 개발이 진행 중이다. 방열에 사용되는 소재로는 Cu가 있으며, 저렴한 가격과 상대적으로 높은 방열 효율을 가지는 장점이 있다. Cu는 전기 도금 증착 방법을 사용하여왔으나, 전기도금 방식으로 증착된 Cu 방열판은 제품에 열이 축적될 경우 Cu와 substrate 사이의 residual stress로 인해 박리나 뒤틀림 현상 등이 발생하여 high power를 사용하는 device의 방열 소재로 사용하기에는 개선해야 할 문제점이 있다. 이러한 문제점을 극복하기 위한 방법으로 magnetron sputter 증착 방법이 있으며, magnetron sputter은 대면적화가 용이하고, 다양한 물질의 증착이 가능한 장점으로 인해 hard coating 또는 thin film 증착과 같은 공정에 사용되고 있다. 특히 증착된 film의 특성을 조절하기 위해서 magnetron sputter에 pulse 또는 ICP (inductively coupled plasma) assisted 등을 적용하여 plasma 특성을 조절하는 방법 등에 관한 연구가 보고되고 있다. 본 연구에서는 pulsed magnetron sputtering 방식을 이용하여 증착된 Cu film 특성 변화를 확인하였다. 다양한 pulsing frequency와 pulsing duty ratio 조건에서, Si substrate 위에 증착된 Cu film과의 residual stress 변화를 측정하였다. Pulse duty ratio가 90% 에서 60%로 감소함에 따라서 Cu film의 residual stress가 감소하였고, pulsing frequency가 증가함에 따라 Cu film의 residual stress가 감소하는 것을 확인하였다. 증착 조건에 따른 plasma의 특성 분석을 위하여 oscilloscope를 이용하여 voltage와 current를 측정하였고, Plasma Sampling Mass spectrometer 를 이용하여 ion energy의 변화를 측정하였다. 이를 통해 plasma 특성 변화가 증착된 Cu film에 미치는 영향과 residual stress의 변화에 대한 연관성에 대하여 확인할 수 있었다.

  • PDF

성교육프로그램이 여중생의 성 지식과 성 태도에 미치는 효과 (Effect of the Sexual Knowledge and Sexual Attitude of the Middle School Women Students through Sexua l Education Program)

  • 정금희;김신정;양순옥
    • Child Health Nursing Research
    • /
    • 제9권4호
    • /
    • pp.420-431
    • /
    • 2003
  • Purpose: This study aims at not only suggesting some ideas useful in planning and doing the sexual education in the middle schools in the near future putting into test the sexual education program which has been developed by researchers in accordance with the national education courses but also improve sexual health of the adolecents through taking right sexual knowledge and sound sexual attitude. Method: Non-equivalent control group pretest-posttest design was used. The number of experimental group students was 37 and the number of controll group students was 37. A total of 74 first grade 'H'middle school girls at H district in KangWon-Do were selected for a convenience sampling method and have been taught the sexual education program during 6weeks, 12times. Result: The findings of the study are as follows: After the sexual education program, the sexual knowledge of experimental group show to be significantly different from that they had before(t=-5.861, p=.000). So, this finding indicating that the adolescent sexual education program helps the ado have and expand the correct sexual knowledge accordingly. In order to look into any change of the sexaul attitudes of experimental group after the sexual education program, there were not significant difference(t=-1.083, p=.286). But some items were significant. It is discovered that the adolescence come to have more affirmative and sound sexual attitude after sexual education program. Conclusion: As the findings of the study indicate, it may be concluded as follows: Since the sexual education program can affirmative influence on the sexual knowledge and sexual attitudes of the adolescence, it is recommendable to perform the sexual education program suitable for every stage of growth and development should be developed, qualified teachers and the educational materials should be reinforced and added enough and institutional device should be made to execute the sexual education program systematically.

  • PDF

간단한 기구부와 결합한 공간증강현실 시스템의 샘플 기반 제어 방법 (Sampling-based Control of SAR System Mounted on A Simple Manipulator)

  • 이아현;이주호;이주행
    • 한국CDE학회논문집
    • /
    • 제19권4호
    • /
    • pp.356-367
    • /
    • 2014
  • A robotic sapatial augmented reality (RSAR) system, which combines robotic components with projector-based AR technique, is unique in its ability to expand the user interaction area by dynamically changing the position and orientation of a projector-camera unit (PCU). For a moving PCU mounted on a conventional robotic device, we can compute its extrinsic parameters using a robot kinematics method assuming a link and joint geometry is available. In a RSAR system based on user-created robot (UCR), however, it is difficult to calibrate or measure the geometric configuration, which limits to apply a conventional kinematics method. In this paper, we propose a data-driven kinematics control method for a UCR-based RSAR system. The proposed method utilized a pre-sampled data set of camera calibration acquired at sufficient instances of kinematics configurations in fixed joint domains. Then, the sampled set is compactly represented as a set of B-spline surfaces. The proposed method have merits in two folds. First, it does not require any kinematics model such as a link length or joint orientation. Secondly, the computation is simple since it just evaluates a several polynomials rather than relying on Jacobian computation. We describe the proposed method and demonstrates the results for an experimental RSAR system with a PCU on a simple pan-tilt arm.

고상 미량 추출 장치(SPME, solid phase micro-extraction device)를 이용한 물 중의 THM(trihalomethane) 분석 (Determination of THM(trihalomethane) in Rain by using Solid Phase Micro-Elctraction(SPME) Fiber Assembly)

  • 유광식;박상윤
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.277-283
    • /
    • 1997
  • SPME deuce was applied to determine the THM in an aqueous solution. The 6 kinds of THM was quantitatively detenuned by using GC-ECD which has the sample eutracted on the SPME fiber from an aqueous solution for 10 min. The THM components were well separated from $CHCl_3$ to the last $CHBr_3$ UHh 13 mons at the condition. 6 kinds of the volatile halogenated organic compounds: $CHCl_3$, $CHBrCl_2$, $CHBrtCl_2$, $CHCl_3$, $C_2Cl$. and $CHBr_3$, showed well defirled calibration graph with good llnearlty from a few ppb level up to several tens of pub concentration. $CHBr_2Cl$ and $C_2C1_4$ were detected from a few samples among the 10 of river samples. CHCl3, however, was detected In 4 sea water samples with the highest of 10 ppd among the pouuted 6 positions. Trace level of $CHBr_2Cl$ and few pub level of $CHBr_3$ were also detected at the other two sample stations. Most of the 13 rain water samples collected from 6 sampling stations were contained ppd level of $CHCl_3$, and also $CHBr_2Cl$, and C_2Cl_4$ were only detected at trace level at a few rain samples among them. We could recognize the fact that our Ut and water enoronment has already been contaminated by certain volatile halogenated organic compounds through this study.

  • PDF

MPPT 제어 기능을 갖는 저전압 진동 에너지 하베스팅 시스템 (A Low-voltage Vibration Energy Harvesting System with MPPT Control)

  • 안현정;김예찬;홍예진;양민재;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.477-480
    • /
    • 2015
  • 본 논문에서는 MPPT(Maximum Power Point Tracking) 제어 기능을 갖는 저전압 진동에너지 하베스팅 회로를 제안한다. 제안된 회로는 Bulk-driven technique을 적용하여 0.8V의 낮은 전압에서도 동작 가능하다. 압전소자의 출력단에 연결된 전파정류기의 개방회로 전압을 MPPT 제어회로를 통해 주기적으로 샘플링하고, 최대 가용전력 점의 전압을 부하에 전달한다. 제안된 회로는 0.35um CMOS 공정으로 설계되었으며, 패드를 포함한 칩 면적은 $1.33mm{\times}1.31mm$이다. 모의실험결과 설계된 회로의 최대 전력효율은 85.49%이다.

  • PDF

GC/MS를 이용한 소변 중 대마 대사체 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of 11-Nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol in Human Urine by GC/MS)

  • 김진영;정재철;서승일;서용준;이정직;김종상;인문교
    • 약학회지
    • /
    • 제52권6호
    • /
    • pp.480-487
    • /
    • 2008
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH), the major metabolite of ${\Delta}^9$-tetrahydrocannabinol, in urine sample by solid-phase extraction (SPE) and GC/MS detection. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day and inter-person validation were performed using statistical analysis of several indicative factors. Measurement uncertainty associated with target analyte in real forensic samples was estimated using quality control (QC) data. Traceability of measurement was established through traceable standards, calibrated volumetric glassware and volume measuring device. The major factors of contribution to combined standard uncertainty, were calibration linearity, inter-day repeatability and inter-person reproducibility, while those associated with preparation of analytical standards and sampling volume were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method was 12.05% for THCCOOH.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.