• Title/Summary/Keyword: Sample matrix

Search Result 700, Processing Time 0.031 seconds

Sorbent Extraction of Some Metal Ions on a Gas Chromatographic Stationary Phase Prior to Their Flame Atomic Absorption Determinations

  • Soylak, M.;Saracoglu, S.;Elci, L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.555-558
    • /
    • 2003
  • An enrichment/separation system for atomic absorption spectrometric determinations of Cu(Ⅱ), Fe(Ⅲ), Ni(Ⅱ) and Co(Ⅱ) has been established. The procedure is based on the adsorption of the analytes as calmagite chelates on Chromosorb-102. The effects of some parameters including pH, amount of ligand, salt matrix, flow rates of sample and eluent solutions were investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (N=5) is generally lower than 5%. The limit of detection (3σ) was between 6.0-112.9 ㎍/L. The results were used for preconcentration of analytes from some sodium and ammonium salt.

Computation of Stress Field During Additive Manufacturing by Explicit Finite Element Method (외연적 유한요소법을 이용한 적층제조 공정 중 응력 장 변화 계산)

  • Yang, Seung-Yong;Kim, Jeoung Han
    • Journal of Powder Materials
    • /
    • v.27 no.4
    • /
    • pp.318-324
    • /
    • 2020
  • In the present work, an explicit finite element analysis technique is introduced to analyze the thermal stress fields present in the additive manufacturing process. To this purpose, a finite element matrix formulation is derived from the equations of motion and continuity. The developed code, NET3D, is then applied to various sample problems including thermal stress development. The application of heat to an inclusion from an external source establishes an initial temperature from which heat flows to the surrounding body in the sample problems. The development of thermal stress due to the mismatch between the thermal strains is analyzed. As mass scaling can be used to shorten the computation time of explicit analysis, a mass scaling of 108 is employed here, which yields almost identical results to the quasi-static results.

Recent Progress on Microfluidic Electrophoresis Device Application in Mass Spectrometry

  • Roy, Swapan Kumar;Kim, Seongnyeon;Yoon, Jung H.;Yoon, Yong-Kyu;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2018
  • Microfluidic technologies hold high promise and emerge as a potential molecular tool to facilitate the progress of fundamental and applied biomedical researches by enabling miniaturization and upgrading current biological research tools. In this review, we summarize the state of the art of existing microfluidic technologies and its' application for characterizing biophysical properties of individual cells. Microfluidic devices offer significant advantages and ability to handle in integrating sample processes, minimizing sample and reagent volumes, and increased analysis speed. Therefore, we first present the basic concepts and summarize several achievements in new coupling between microfluidic devices and mass spectrometers. Secondly, we discuss the recent applications of microfluidic chips in various biological research field including cellular and molecular level. Finally, we present the current challenge of microfluidic technologies and future perspective in this study field.

The structure properties of polymer composite (고분자 복합재료의 구조적 특성)

  • Noh, Hyun-Ji;Lee, Sung-Gap;Nam, Sung-Pill;Kim, Da-Mi;Ahn, Byeong-Lib;Won, Woo-Sik;Woo, Hyoung-Gwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.262-263
    • /
    • 2009
  • To add Nanofiller in the epoxy which is used with the solid insulation material of existing and is a research which observes the improvement of the structural quality to produce the Nanocomposite. Montmorillonite uses with Nanofiller, MMT of the content expense (wt%) which is various and mixed an epoxide and produced sample. According to content of the sample result MMT according to respectively content expense to measure SEM photographing which is the possibility of knowing the minute structure of section with sample where is produced and the tensile strength will be able to observe the change of quality. MMT silicate layer uniformly more in the result and within epoxy matrix, being dispersed, will be able to observe.

  • PDF

Determination of Corticosteroids in Moisturizers by LC-MS/MS

  • Park, Sumin;Choi, Gye Young;Lee, Seon-Ah;Kim, Hyun Jeong;Yum, Hye Yung;Paeng, Ki-Jung
    • Mass Spectrometry Letters
    • /
    • v.7 no.1
    • /
    • pp.26-29
    • /
    • 2016
  • Simultaneous determination of three corticosteroids (clobetasol propionate, betamethasone dipropionate, fluticasone propionate) in moisturizers was performed by using liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). Sample preparation was conducted by the liquid-liquid extraction (LLE). Moisturizers include emulsifying agent and it forms micelles. In order to improve the extraction efficiency of corticosteroids trapped in micelle, newly developed-optimized extraction conditions which can remove the matrix effect from moisturizers was applied with various pH conditions in LLE extraction stage of sample preparation. Thus, the addition of 10 μL of 1 M HCl into moisturizers sample before extraction could improve the extraction efficiency. For the quantitative analysis, SRM table that contained specific transition of all of target corticosteroids was created. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), limit of quantization (LOQ) and recovery. Over the 0.99 r2 value was obtained in calibration standard range. Effective accuracy and precision were also obtained. LODs were below 31 ng/mL and LOQs were estimated below 94 ng/mL for all corticosteroids tested.

Effects of Pressure on Properties of SiC-$ZrB_2$ Composites through SPS (SPS법에 의한 SiC-$ZrB_2$ 복합체의 특성에 미치는 압력의 영향)

  • Shin, Yong-Deok;Lee, Jung-Hoon;Kim, Chul-Ho;Jin, Beom-Soo;Wu, Na
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1449-1450
    • /
    • 2011
  • The SiC-$ZrB_2$ composites were produced by subjecting a 40:60 (vol.%) mixture of zirconium diboride($ZrB_2$) powder and ${\beta}$-silicon carbide (SiC) matrix to spark plasma sintering(SPS) under argon atmosphere at 50MPa(P50) and 60MPa(P60) pressure. The relative density, 94.13% of P60 sample was lower than that, 94.75% of P50 sample. Reactions between ${\beta}$-SiC and $ZrB_2$ were not observed via x-ray diffraction (hereafter, XRD) analysis. The trend of flexural strength of SiC-$ZrB_2$ composites were in accordance with the relative density. The properties of a SiC-$ZrB_2$ composites through SPS under argon atmosphere were positive temperature coefficient resistance in the temperature range from $25^{\circ}C$ to $500^{\circ}C$, and electrical resistivity of P50 and P60 sample were $6.75{\times}10^{-4}$ and $7.22{\times}10^{-4}{\Omega}{\cdot}cm$ at room temperature, respectively.

  • PDF

The Infrared Absorption Spectra of Molecular Clusters of Acetonitrile and DMF Diluted by Matrices at 80K (매트릭스에 의해 희석된 ACETONITRILE과 DMF 분자클라스터의 80K에서 적외선 흡수 스펙트럼의 분석)

  • Kim, Wan Hee;Jeong, Jong Hak;Jeong, Gi Ho
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.285-294
    • /
    • 1992
  • Structures of dimers of the acetonitrile and DMF diluted by carbon-tetrachloride and xenon matrices at 80K were studied with infrared absorption spectroscopy. Sample and matrix materials were codeposited onto a KBr cold trapping window. Infrared absorption spectra of pure samples and diluted samples were compared to explain the structures of dimers. The acetonitrile dimer showed the antiparallel shape and the DMF dimer showed the linear shape. After annealing, the infrared spectrum of the diluted sample showed the same shape with that of the pure sample.

  • PDF

Microstructure and Mechanical Properties of Ti-6Al-4V Alloy Processed by Metal Injection Molding (금속분말 사출성형된 Ti-6Al-4V 합금의 미세조직 및 기계적 물성)

  • Kim, M.J.;Baek, S.H.;Yoon, D.K.;Lee, E.H.;Kim, J.H.;Ko, Y.G.
    • Transactions of Materials Processing
    • /
    • v.29 no.5
    • /
    • pp.251-256
    • /
    • 2020
  • The purpose of this study is to investigate the effect of sintering condition on the microstructure evolution and tensile properties of the Ti-6Al-4V alloy sample processed by metal injection molding (MIM) in terms of the sizes of the alpha morphology and pore found in the matrix. For this purpose, a series of MIM were conducted on this sample at various sintering temperatures ranging from 1173 to 1373 K for three hours followed by furnace cooling, observed by the scanning electron microscopy. The microstructures sintered in this study showed that, with increasing sintering temperature over beta transus temperature, the transformation of the equiaxed alpha into transformed beta was attained while the size of pores would tend to decrease. Thus, the strength remained unchanged significantly in the tension while ductility increased to some extent as sintering temperature increased. Such mechanical behavior would be explained in relation to the microstructure evolution of the Ti-6Al-4V sample via the MIM.

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

Characterization and Electrical Properties in (YNS)BCO Oxides by Rod-type Seeded Melt Growth Process

  • Kim, So-Jung;Park, Jong-Kuk;Lee, Sang-Gyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.243-243
    • /
    • 2007
  • We have studied the electrical properties and microstructure of $(Y_{0.5}Nd_{0.25}Sm_{0.25})Ba_2Cu_3O_y[(YNS)-123]$ Oxides by rod-type seeded melt growth process(RSMG) in air atmosphere. Rod-type $NdBa_2Cu_3O_y${Nd-123) seed crystals made a extrusion process method, were used for achieving the ab-plane alignment having large grains perpendicular to the center of (YNS)-123 samples. The observations using SEM and TEM micrographs of the melt-textured (YNS)-123 samples revealed that the nonsuperconducting $(Y_{0.5}Nd_{0.25}Sm_{0.25})Ba_2Cu_3O_y[(YNS)-211]$ inclusions are uniformly distributed in the superconducting matrix. The microstructure and electrical properties were investigated by XRD, SEM, TEM and DC SQUID magnetometer. The sample showed a sharp superconducting transition at 90 K. The magnetization values of the (YNS)-123 sample exhibited the enhanced electrical properties, compared with $YBa_2Cu_3O_y$(Y-123) sample.

  • PDF