• Title/Summary/Keyword: Sample Holder

Search Result 83, Processing Time 0.026 seconds

Development of microcomputer-based on-line measurement system. (마이크로컴퓨터를 이용한 온-라인 측정 시스템의 개발)

  • ;;Chung, Myung Kyoon;Lee, Dong In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.4
    • /
    • pp.274-283
    • /
    • 1981
  • An inexpensive and very simple microcomputer-aided measurement system has been designed for on-line experiments, which perform simultaneously data acquisition, data recorditing, calculations with the data, and positioning of necessary sensors. Interfacting between the microcomputer and the data acquisition board which consists of A/D converter, analog multiplexer, and sample-and-holder, etc. has been done through IEEE-488 interface port and parallel user port both provided by the PET computer's main logic board. Data and control signals are transfered between devices without handshaking. By utilizing BASIC commands PEEK, POKE, SYS, USR which are offered by PET microcomputer, it is possible to link machine code subroutines into the main BASIC program. This facilitates ease of data transfer, programming, and speedy execution of the program. In addition, an X-Y scanning table has been concected to the system in order to automatically position measuring sensors along a pre-determined path of interest.

Complex Permittivity Extraction of Blood Glucose at Microwave Frequency

  • Jeong, You-Chul;Lee, Hee-seok;Kim, Joung-ho
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.2
    • /
    • pp.139-145
    • /
    • 2001
  • In this paper, a coaxial sample holder is proposed with its de-embedding and parameter extraction procedure. The S-parameters were measured up to 1 GHz using network analyzer, HP8753D, and N-type connector together with the de-embedding of N-type connector. The proposed de-embedding procedure is performed to extract electrical parameters of blood glucose, which gives the permittivity of blood glucose. We also analyzed the error of extracted parameters, which are caused by instrument error and geometrical error. Using these error analyses, we reduced the error factors of extracted parameters. We extracted electrical parameters of glucose samples through these all extraction procedure and confirmed the possibility of glucose diagnosis system based on microwave system.

  • PDF

Manufacturing of Micro Dotting Pin (DNA Chip 용 마이크로 핀에 관한 연구)

  • 신홍규;이영수;남권선;김병희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.500-504
    • /
    • 2004
  • The bio-micro pin has been usually used for the biochemistry analysis. The manufacturing capability of the micro-pin and the their array with the effective and low-cost way is very important and it gives great economical benefits to developers. The micro-pin is composed of the sample channel for holding the liquid with the fixed volume, the flat tip which determines the printing quality and the pin head for preventing the rotation of the pin in the holder. In this study, we have manufactured newly designed micro-pins by the wire-EDM process with special jigs, and analyzed liquid holding and printing characteristics with respect to the variation of the shape and the tip size of the micro-pin.

  • PDF

The design of filters for multi-channel cardiac activation main amplifier (다중 채널 심장전기도 주 증폭기를 위한 필터 설계)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.180-184
    • /
    • 2010
  • In this paper, the filter design and simulation are performed to construct the multi-channel cardiac activation main amplifier. The main amplifier consists of sample and holder, variable high pass filter, notch filter, variable low pass filter. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution and the filter is designed for 128 channels cardiac activation main amplifier.

Dependence of thermal cycling and axial strain on HTS PIT tapes (고온초전도 PIT선재의 반복 열응력 및 변형률 의존성)

  • 하홍수;이동훈;최정규;양주생;황선역;김상철;하동우;오상수;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.131-133
    • /
    • 2003
  • The effect of axial strain and thermal cycling on the critical current is investigated for the Bi-2223/Ag PIT tapes. The axial strain was applied to the tapes by the U-shape sample holder. Two kinds of Bi-2223/Ag tapes with different Ag sheath are used to know the effect of sheath alloying for the tensile strain. The influence of thermal cycling between room temperature and 77 K on critical current are examined. Critical current is drastically decreased for Ag/alloy and Ag/alloy/alloy sheathed tapes at tensile strain above 0.22% and 0.3%, respectively.

  • PDF

Ellipsometry 에서의 calibration 및 입사면 고정형 ellipsometer

  • 경재선;방경윤;최은호;손영수;안일신;오혜근
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.18-22
    • /
    • 2003
  • 일반사용자들은 ellipsometer를 사용이 어려운 장비로 인식하고 있다. 본 연구는 초보자들이 손쉽게 사용할 수 있는 ellipsometer를 제작하는데 목적이 있다. 시편을 측정하기 전에 반드시 해야 할 과정인 alignment와 calibration을 하지 않고 측정할 수 있도록 제작하였다. 기본 구조는 rotating compensator spectroscopic ellipsometry를 이용하였으며 , 입사각을 70도로 고정시키고 기존의 sample holder 구조를 바꾸어 어떠한 시편을 놓아도 입사면이 변하지 알게 하여 calibration 이 요구되지 않는 ellipsometer를 개발하였다. 장비의 성능과 정밀도를 검사하기 위하여 여러 가지 표준시료를 측정하여 일반 RCSE와 측정결과를 비교하였다. 또한 고정된 입사면의 calibration값의 신뢰도를 검사하기 위하여 반복적으로 측정할 때마다 시편을 재배치하여 실험하였다.

  • PDF

16 Channel Strain Gauge Measuring Ubiquitous System Development (유비쿼터스 지향의 16채널 스트레인 게이지 계측 시스템 개발)

  • Jang, Soon-Suk;Kim, Kyung-Suk;Won, Yong-Ill;Kim, Dae-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.912-917
    • /
    • 2006
  • A strain gauge weight measuring instrumentation system was designed with RF sensor network facilities. In the sensor module system data conversion and a series of signal processing were totally equipped. 16 strain gauges are incoming sensors and each output of the strain gauge was amplified and filtered for proper analog signal processing. Several measuring instrumentation OP amps and general purposed OP amps were used. 12 bits A/D converters converted analog signals to digital bits and a PIC microprocessor controlled the 16 channels of strain gauges. RF RS232 modules were used for wireless communication between the PIC microprocessor and an Ethernet host far a remote sensor monitoring system development.

The recording of surface relief grating on the chalcogenide thin film (비정질 칼코게나이드 박막에 Surface Relief 격자 형성)

  • 박종화;장선주;박정일;여철호;이영종;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.299-302
    • /
    • 2000
  • In this study, we have made the large holographic surface relief gratings on amorphous chalcogenide $As_{40}$$Ge_{10}$$Se_{15}$$S_{35}$ films by two beam interference using a He-Ne laser(632.8nm) light. The film thickness was about 0.6$\mu\textrm{m}$, we could magnify beam size by using beam expander. We made use $90^{\circ}$ holder which was made of reflection mirror and sample. Formed the surface relief structures were investigated using optical microscope. The diffraction efficiency was obtained by measuring +lst order intensity. In addition we investigated grating formation and diffraction efficiency as a function of polarization states which is linear or circular polarization. The results indicate that the grating was formed by linear polarized beam is better clear than that by circular polarized beam.

  • PDF

A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice (산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF

Acoustic Characteristics of Watermelon According to Impact Conditions (타격조건에 따른 수박의 음파특성)

  • 최동수;최규홍;이영희;이강진;김만수
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.67-76
    • /
    • 2002
  • This study was conducted to investigate the effects of impact conditions on the acoustic characteristics of a watermelon. The study was crucial to develop a device for nondestructive internal quality evaluation of a watermelon by an acoustic impulse response method. An impact device was constructed with a pendulum to hit the watermelon, a microphone to detect the acoustic impulse responses, and a digital oscilloscope and computer to store and analyze the data. The selected samples were Guemcheon cultivar watermelons(Citrulus Vulgaris Schrad) harvested on Oct. 20,1998. Sixty watermelons were tested on flour different types of sample holders, with four kinds of ball made of different materials, at four bevels of the angular position of the pendulum and distance from the watermelon to the microphone. Since the magnitudes of frequencies obtained by hitting with the steel and rubber ball were relatively small at the bandwidths of above 500 Hz, it was shown that the steel and rubber ball were not suitable far a hitting ball in the pendulum to get informations on internal quality of the watermelon. In case of using broth of the wood and acryl ball, almost the same and good acoustic responses were shown on the wide range of frequency bandwidth. Therefore, it seemed that the acryl ball was more suitable to the test than the wood ball in considering its mechanical properties. The acoustic characteristics of the watermelon were not shown a significant difference between the types of sample holder. The amplitudes of the acoustic signals and the magnitudes of frequencies from the whole samples increased with increase of the angular position of pendulum and with decrease of the distance from the watermelon to the microphone. However, the resonance resonance of the sample were almost the same regardless of the angular positions and the distances.