• 제목/요약/키워드: Salmonella O antigen

검색결과 7건 처리시간 0.023초

포도구균의 A단백질을 이용한 효소면역법으로 살모넬라 O항원 검출 (An Improved Method for Detection of Salmonella Typhi O Antigen with Staphylococcal Protein A Using Enzyme Immunoassay)

  • 유문간;김금룡;이중기
    • 대한미생물학회지
    • /
    • 제22권4호
    • /
    • pp.445-451
    • /
    • 1987
  • Coagglutination method is widely used for the diagnosis of Salmonella infection. This test, however, has a disadvantage of false positive reaction due to the coagglutination of staphylococci with non-specific immune complexes or anti-staphylococci antibody in serum. Salmonell O antigen was detected by enzyme immunoassay with protein A-bearing Staphylococcus aureus as in the solid phase. Horse radish peroxidase was labeled to IgG specific against Salmonella O antigen. This enzyme immunoassay was much more sensitive than conventional coagglutination method without false poitive agglutination. To improve the sensitivity for detection of Salmonella O antigen in samples, we tried to determine the optimal concentration of normal IgG that inhibits non-specific binding of horse radish peroxidase labeled IgG to staphylococci, and to establish the optimal condition of reaction between antigen-antibody complex and staphylococci. Non-specific binding of horse radish peroxidase labeled specific IgG to staphylococci was almost blocked when the enzyme labeled IgG was 500-fold diluted with phosphate buffered saline containing 2mg/ml of normal IgG. When staphylococci coated with antibody to Salmonella O antigen were mixed with antigen-antibody complex and then incubated for 1 hour at room temperature, the minimal detectable concentration of Salmonella O antigen was 1ng/ml. The sensitivity of enzyme immunoassay was 100-fold greater than a conventional coagglutination method. This enzyme immunoassay could be expected as an improved method for detection of other infectious agents.

  • PDF

Fe3O4 나노분말을 이용한 전기화학적 비효소 면역센서 응답특성 (Response Characteristics of Electrochemical Non-enzyme Immunosensor using Fe3O4 Nanoparticle)

  • 김창규;이경자;엄영랑;이민구;이창규
    • 한국분말재료학회지
    • /
    • 제16권3호
    • /
    • pp.180-184
    • /
    • 2009
  • In this paper, the electrochemical non-enzyme immunosensor has been developed for the determination of salmonella antigen, using inverse voltammetry. For the estimation of salmonella antigen concentration, the $Fe_3O_4$ nanoparticles synthesized by microemulsion method were conjugated with salmonella antigen. Then, the immunocomplex between antibody immobilized on the transducer surface and antigen containing a magnetic nanoparticles was formed. From the linear relationship between the reduction peak current of Fe(III) and salmonella antigen concentration, it is suggested that the electrochemical non-enzyme biosensor is applicable to detect salmonella antigen in the concentration range of $10^1-10^5$ CFU/ml.

Mix LPS-ELISA법을 이용한 살모넬라균 복합감염항체 동시 모니터링 (Application of mix LPS-ELISA for monitoring of antibodies to major serogroups of Salmonella in animal)

  • 이희수;임숙경;우승룡;이유영;김종염;주이석;김종만
    • 대한수의학회지
    • /
    • 제38권4호
    • /
    • pp.793-802
    • /
    • 1998
  • Salmonellosis caused by a number of serotypes of Salmonella is an infectious, acute or chronic, zoonotic disease and characterized by enteritis and diarrhea, septicemia in animal. In these studies we investigated the prevalent serotypes of Salmonella causing animal salmonellosis in Korea and the 71 strains of Salmonella spp. were isolated from materials such as mesenteric lymph nodes, fecal samples from slaughtered animal. With the identification test results, the most prevalent serotypes were, in order, S stanley 31 strains (43.7%), S typhimurium 19 strains (26.8%) and S montevideo 11 strains (15.5%), respectively. And we could establish the method for detection of antibodies to broad variety of Salmonella serotypes. Lipopolysaccharide(LPS) antigen extracted from Salmonella was more sensitive and specific than outer membrane protein antigen from that for detection of Salmonella antibody by using an indirect ELISA. The optimal concentration of antigen was 100ng/ml of LPS, the dilutions of conjugate and serum were 1 : 1,000~2,000 and 1 : 200~400, respectively. The mix LPS-ELISA which was used by mixing LPS from S typhimurium (group B), S choleraesuis (group C) and S enteritidis (group D) were more rapid and effective than that used LPS from individual strain for detection of Salmonella serogroup O4, O7 and O9 antibody at the same time. We could obtain the high values of optical density ($0.73{\pm}0.32$) by mix LPS-ELISA on the farm which had occurred salmonellosis, but very low values of $0.17{\pm}0.06$ on the negative farm of salmonellosis. So, the mix LPS-ELISA may be used to monitor the serological surveillance for the presence of infection with a number of serotypes of Salmonella and would be useful for prevention and control of salmonellosis in animal.

  • PDF

ANALYSIS AND MANIPULATION OF CANDIDATE GENES FOR DIARRHEAL DISEASE VACCINE DEVELOPMENTS

  • Kim Young-Chang
    • 한국미생물학회:학술대회논문집
    • /
    • 한국미생물학회 2000년도 International Meeting 2000
    • /
    • pp.58-65
    • /
    • 2000
  • Diarrheal diseases are a major cause of both illness and death in developing countries and are caused by rotavirus, Shigella spp., Salmonella spp., enterotoxigenic Escherichia coli (ETEC), and Vibrio spp. In this study, for the development of vaccine against diarrheal diseases caused by Shigella sonei, Salmonella typhimurium, E. coli O157, and Vibrio cholerae, cloning and nucleotide sequence analysis of genes and characteristics of their gene products in E. coli were performed. For construction of attenuated strain of S. sonnei KNIH104 and Salmonella typhimurium KNIH100, the aroA genes were cloned, respectively. The recombinant plasmid $_pJP{\Delta}A45$ containing aroA deleted region and suicide vector $(_pJP5603)$ was constructed. The aroA gene deleted mutants were constructed using this recombinant plasmid. For cloning gene encoding antigenic region of E. coli O157 KNIH317, the O-antigen synthesis gene cluster and sit gene was cloned. The E. coli XL1-Blue cells harboring this recombinant plasmid showed cytotoxicity in Vero cells. The ctx gene was cloned for tile purpose of antigenic region against V. cholerae KNIH002. Sequence analysis confirmed that the virulence gene cassette was consisted of ace, zot, ctxA and ctxB genes.

  • PDF

효소면역측정법을 위한 장티푸스 균체항원의 부착방법 (Methods for Coating the Killed Whole Cell Antigens of Salmonella typhi in Enzyme-linked Immunosorbent Assay)

  • 김윤원;황응수;국윤호;최강원;김익상;차창용;이승훈
    • 대한미생물학회지
    • /
    • 제20권1호
    • /
    • pp.91-102
    • /
    • 1985
  • The advantages of enzyme-linked immunosorbent assay(ELISA) are its senstivity and simplicity in detecting IgG, IgM and IgA antibody. To apply ELISA to diagnosis of typhoid fever, antigen such as lipopolysaccharide of Salmonella typhi or killed whole cell must be coated on solid phase. It is easy to coat lipopolysaccharide on ELISA plate but troublesome to purify it. As it is easy to obtain the killed whole cells, the development of the appropriate method by which those antigens of S. typhi are optimally coated on solid phase is needed. To establish the appropriate method, carbonate buffer, methanol or poly-L-lysine was applied as binding substance on polystyrene or polyvinylchloride plate as solid phase when the killed whole cell antigens of S. typhi varided as follows: $10^6$, $10^7$, $10^8$ and $10^9\;cell/ml$. The criteria of the optimal method were determined as follows: 1. The optical density of positive sera is above 1.0(0.6 in IgM) at 1:10 serum dilution and is 0.3(0.2 in IgM) higher than that of negative sera: 2. The O.D. of sera is flat or lowering according to serum dilution: 3. It must be that the O.D. of negative sera is lower than 0.2 at the point of serum dilution where the O.D. of positive sera is higher than 1.0(0.5 in IgM). The results obtained were summarized as follows: 1. The methods which fitted the above criteria were to use poly-L-lysine as binding substance, polyvinylchloride plate as solid phase and $10^7\;cell/ml$ as antigen concentration of S. typhi(poly-L-lysine/polyvinylchloride/$10^7$) and poly-L-lysine/polyvinylchloride/$10^8$ in detecting IgG antibody, methanol/polystyrene/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgM and carbonate buffer/polystyrene/$10^8$, carbonate buffer/polystyrene/$10^9$, methanol/polystyrene/$10^8$, methanol/polyvinylchloride/$10^8$, methanol/polyvinylchloride/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgA. 2. The coaling method using poly-L-lysine, polyvinylchloride plate and $10^8\;cell/ml$ was best to assay IgG, IgM and IgA antibody all in one. By this method, to assay the each immunoglobulin calss with an appropriate fixed serum dilution, 1:320 dilution was best.

  • PDF

Development of Chicken Immunoglobulin Y for Rapid Detection of Cronobacter muytjensii in Infant Formula Powder

  • Kim, Yesol;Shukla, Shruti;Ahmed, Maruf;Son, Seokmin;Kim, Myunghee;Oh, Sejong
    • 한국축산식품학회지
    • /
    • 제32권6호
    • /
    • pp.706-712
    • /
    • 2012
  • The present study was aimed to produce a chicken polyclonal antibody against Cronobacter muytjensii and to develop an immunoassay for its detection. Purification of anti-C. muytjensii IgY from egg yolk was accomplished using various methods such as water dilution and salt precipitation. As a result, sodium dodecyl sulfate-polyacrylamide gel electrophoresis produced two bands around 30 and 66 kDa, corresponding to a light and a heavy chain, respectively. Indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was performed to determine the effectiveness of the chicken IgY against C. muytjensii. The optimum conditions for detecting C. muytjensii by indirect ELISA and checkerboard titration of the antigen revealed an optimum average absorbance at the concentration of 18 ${\mu}g/mL$, having ca. $10^8$ coated cells per well. The anti-C. muytjensii IgY antibody had high specificity for C. muytjensii and low cross-reactivity with other tested pathogens. In this assay, no cross-reactivity was observed with the other genera of pathogenic bacteria including Escherichia coli O157:H7, Salmonella Typhimurium, Staphylococcus aureus, Bacillus cereus, Enterobacter aerogenes, Salmonella Enteritidis and Listeria monocytogenes. In addition, detection of C. muytjensii in infant formula powder showed a low matrix effect on the detection curve of IC-ELISA for C. muytjensii, with similar detection limit of $10^5$ CFU/mL as shown in standard curve. These findings demonstrate that the developed method is able to detect C. muytjensii in infant formula powder. Due to the stable antibody supply without sacrificing animals, this IgY can have wide applications for the rapid and accurate detection of C. muytjensii in dairy foods samples.

면역크로마토그래피를 이용한 E. coli O157: H7 신속검출 키트의 유효성 평가 (Evaluation of the Efficiency of E. coli O157: H7 Rapid Detection Kit using Immunochromatography)

  • 곽효선;이동하;문희숙;박종석;우건조;김창민
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.118-124
    • /
    • 2003
  • 식품으로부터 다양한 병원 미생물을 신속 검출하기 위하여 다양한 검출 원리를 이요한 키트들이 개발 시판되고 있다. 검사키트는 신속, 정확하고 간단하게 사용할 수 있으므로 검사기관이나 실험실 뿐 아니라 식품회사에서 QC 또는 QA를 수행하기 위하여 사용이 증가되고 있는 추세이다. 이에 본 연구에서는 E. coli 0157:H7의 단클론항체를 이용하여 면역크로마토글래피법에 의해 개발된 E. coli 0157:H7 검출 키트(Donga Co, Korea, D-kit)에 대한 검출감도 및 특이성을 확인하고 식품 시료에 적용 가능성을 평가하였다. 면역크로마토그래피법에 의하여 개발 시판되고 있는 Reveal E. coli 0157:H7 kit (Neogen Co., USA. R-kit)와 VIP EHEC kit(Biocontro Inc., USA. V-kit)를 비교 키트로 사용하였다. E. coli 0157:H7 표준균주를 사용하여 실시한 검출감도 확인시험 결과 R-kit 및 D-kit는 104/m/의 농도에서 양성으로 확인되었고 $10^3$/ml에서도 약한 양성 반응을 보였으나, V-lit는 $10^5$/ml농도로 검출감도가 낮았다. 또한, 배양액을 가열하여 kit에 적용하는 것이 가열하지 않은 경우보다 검출감도를 높일 수 있었다. E. coli 0157:H7 분리 22주, verotoxin 생성 E. coli 7주 E. coli 분리주 40주 중 3주를 제외한 모든 균에서 음성의 결과를 보여 특이성을 확인하였다. 세 키트에 위양성 반응을 보인 것은 E. coli 0157:H19, E. coli 0148:H18 및 Salmonella gallinarium으로 이들 혈청형과 0157:H7 사이에는 유사한 혈청학적 특성이 존재하는 것으로 추정되었다. 이상의 실험결과로 D-kit는 E. coli 0157:H7을 검출하는데 감도 및 특이성 면에서 기존 키트인 R-kit 및 V-kit와 같이 이용한 것으로 확인되었다.