• Title/Summary/Keyword: Sagnac interferometer

Search Result 47, Processing Time 0.022 seconds

Detection of excited vibration frequency on the latticed fence structure using a distributed fiber optic sensor (격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험)

  • Lee, Jongkil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.329.1-329
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in lengtn, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber-optic external vibration signal applied to the latticed structure from 100㎐ to several ㎑. (omitted)

  • PDF

Design of Distributed Fiber Optic Sensor Net for the Detection of External Sound Frequency (외부 음향 주파수 탐지를 위한 분포형 광섬유 센서망 설계)

  • 이종길
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.792-796
    • /
    • 2003
  • In this paper, to detect external sound frequency on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 50cm in width and 50cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. Single mode fiber, a laser with 1,550nm in wavelength, 2${\times}$2 coupler were used. External sound signal applied to the fiber optic sensor net and the detected optical signals were compared and analyzed to the detected microphone signals against time and frequency domain. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

  • PDF

Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net (분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지)

  • 이종길
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

A Study on the New Hybrided Optical Filter for Wavelength Tunable Fiber Ring Laser (파장 가변 링 레이저를 위한 새로운 복합연결형 광 필터에 대한 연구)

  • Kim, Kwang-Yoo;Lee, Jung-Ryul;Eom, Jin-Seob
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12A
    • /
    • pp.1177-1181
    • /
    • 2006
  • In this paper, we proposed the new wavelength tunable filter for wide tunability of fiber ring laser. The proposed filter consists of the cascaded connection of Fiber Reflection Mach-Zehnder Interferometer and Sagnac filter or of hybrid filter and fiber Reflection Mach-Zehnder Interferometer. The simulation shows that the continuous tunable range of 50nm can be obtained and that more stable single mode operation of ring laser can be expected due to narrow FWHM. of filter spectrum.

Analysis of Sagnac Loop Band-pass Filter in Incorporating Fiber Bragg Gratings (FBG를 삽입한 사냑 루프 대역 통과 필터의 해석)

  • Jung, Eun-Joo;Jeong, Myung-Yung;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2007
  • A tunable band-pass filter of fiber Bragg gratings incorporating the Sagnac loop interferometer configuration is presented. The proposed band-pass filter with extinction ratio 20 dB has practical advantages in terms of price and performance in comparison with the conventional band-pass filter using a circulator.

Polarimetric Fiber Pressure Sensor Incorporating Polarization-Diversity-Loop-Based Sagnac Interferometer (편광상이 고리 구조 기반 사냑 간섭계를 이용한 편광 간섭형 광섬유 압력 센서)

  • Ryu, Uh-Chan;Choi, Sung Wook;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, we demonstrated a polarimetric fiber pressure sensor using a polarization-diversity-loop-based Sagnac interferometer(PDLSI) composed of polarization-maintaining fiber(PMF) and a fiber Bragg grating(FBG). In order to compare the pressure sensitivity for various kinds of PMF, three kinds of bow-tie PMF were employed as sensor heads. The maximum pressure sensitivity was measured as approximately -15.07nm/MPa, and an R2 value to represent sensor linearity was measured as ~0.992 at the sensor system using corresponding PMF over a pressure range of 0-0.3MPa. An FBG was utilized and located adjacent to the PMF segment for compensating temperature-induced errors in the measurement of pressure. The pressure sensitivity of the proposed sensor was improved by approximately four times compared with the previously reported pressure sensor based on polarization-maintaining photonic crystal fiber.

A study on stabilization of a fiber-optic current sensor using sagnac interferometer (Sagnac 간섭계형 광섬유 전류센서의 안정화 연구)

  • 정래성;강현서;이종훈;송정태;이경식
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.94-99
    • /
    • 1997
  • A new method of stbilizing the sagnac interferometric fiber optic current sensor inteh presence of birefringences and phase is presented. This method is realized by dividing the output of the ac current signal with the modulation signal output. Using the technique the stability of the current sensor was improve dmore than 4.5 times at 800Arms for 2 hours. The current sensor also shows good linearity up to 100Arms.

  • PDF

A Simple Method for Chromatic Dispersion Measurement Using Sagnac Interferometer with Mach-Zehnder Modulator (Mach-Zehnder 변조기를 갖는 Sagnac 간섭기를 이용한 간단한 색분산 측정법)

  • Jeon, Geum-Su;Kim, Hui-Ju;Gang, Dong-Seong;Ban, Jae-Gyeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.706-711
    • /
    • 2001
  • In this paper we propose the simple system for measuring the chromatic dispersion of a fiber by using Sagnac interferometer with a Mach-Zehnder modulator and induce the equivalent model and the transfer function of this system. The chromatic dispersion of fibers with length of 2.235km is measured by using this method in wavelength region from 1500nm to 1580nm and we conform that the measured results had a good agreement with the theoretical results given Corning Fiber.

  • PDF