• Title/Summary/Keyword: Sagnac interferometer

Search Result 47, Processing Time 0.168 seconds

Principles and Prospects of Sagnac Interferometer Gyroscopes (사냑간섭계 원리를 이용한 자이로의 원리와 발전 전망)

  • Shim, Kyu-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.203-210
    • /
    • 2012
  • Sagnac interferometer gyroscopes can be divided into three large generations using starting points of time or highlights of their research. As the first generational Sagnac interferometer, the ring laser gyroscopes have been studied since the 1960s by laser invention, and as the second generational Sagnac interferometer, the fiber optic gyroscopes have been studied since the 1970s by invention of optical fiber for communication. In the latter half of the 1990s, after having confirmed the wave theory of the atom, studies of atomic interferometers were started for a next generation gyroscope application. This paper discusses the operation principles, application, and future prospects of these three generations of Sagnac gyroscopes.

Non-contact Detection of Ultrasonic Waves Using Fiber Optic Sagnac Interferometer (광섬유 Sagnac 간섭계를 이용한 초음파의 비접촉식 감지)

  • Lee, Jeong-Ju;Jang, Tae-Seong;Lee, Seung-Seok;Kim, Yeong-Gil;Gwon, Il-Beom;Lee, Wang-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1400-1409
    • /
    • 2001
  • This paper describes a fiber optic sensor suitable for non-contact detection of ultrasonic waves. This sensor is based on a fiber optic Sagnac interferometer. Quadrature phase bias between two interfering laser beams in Sagnac loop is introduced by a polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output versus phase bias. This method eliminates a digital signal processing for detection of ultrasonic waves using Sagnac interferometer. Interference intensity is affected by the frequency of ultrasonic waves and the time delay of Sagnac loop. Collimator is attached to the end of the probing fiber to focus the light beam onto the specimen surface and to collect the reflected light back into the fiber probe. Ultrasonic waves produced by conventional ultrasonic transducers are detected. This fiber optic sensor based on Sagnac interferometer is very effective for detection of small displacement with high frequency such as ultrasonic waves used in conventional non-destructive testing.

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

  • Park, Sang-Joon;Kim, Hyoung Joo;Noh, Jaewoo
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.277-281
    • /
    • 2012
  • We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

Exciting Frequency Detection of Latticed fence Structure Using Fiber Optic Interferometer Sensor (간섭계형 광섬유 센서를 이용한 격자형 구조물의 외부 가진 진동수 탐지)

  • 이종길
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.142-148
    • /
    • 2004
  • In this paper, to detect exciting frequency on the latticed fence structure, fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 180 cm wide and 180 cm high, the optical fiber, 50 m in length, distributed and fixed on the latticed structure. Single mode fiber, a laser with 1,550 m wavelength, and $3{\times}3$ coupler were used. Excited vibration signal applied to the latticed structure from 200 Hz to 1 KHz. The detected optical signals were compared to the detected acceleration signals and analyzed on the time and frequency domain. Based on the experimental results, fiber optic sensor using Sagnac interferometer detected exciting frequency, effectively. This system can be applied to the structural health monitoring system.

Single Photon Interference Experiments in a Sagnac-type Mach-Zehnder Interferometer (Sagnac 형태로 변형된 Mach-Zehnder 간섭계를 이용한 단일광자 간섭실험)

  • Um, Jayoon;Kim, Yong Soo;Kim, Heonoh
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.2
    • /
    • pp.71-76
    • /
    • 2012
  • A Sagnac-type Mach-Zehnder interferometer(SMZI) is a very stable instrument with respect to phase drift because all optical paths can share common optical components. We have observed very stable interference fringes in single photon interference experiments with an extremely attenuated laser beam, and with heralded single photons prepared from polarization correlated photon pairs in type-II spontaneous parametric down-conversion. The phase stability is measured to be about ${\pm}0.18$ rad for the SMZI, in contrast, conventional MZI showed the phase fluctuation of around ${\pm}1.02$ rad.

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor (격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험)

  • Lee, Jong-Kil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

Discharge Signal Detection in Insulating Oil using the Optial Fiber Sagnac Interferometer (광섬유 Sagnac 간섭계를 이용한 유중방전 신호검출)

  • Lee, Jong-Kil;Lee, June-Ho;Kim, Sang-Joon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.622-626
    • /
    • 2000
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals. The needle-sphere electrode system in insulating oil generated the signals. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT actuator at 198KHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array (Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구)

  • Lee, Jog-Kil;Lee, Seung-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF