• Title/Summary/Keyword: Sag Resistance

Search Result 23, Processing Time 0.021 seconds

Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters (두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR))

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.

Distribution of KRAS and BRAF Mutations in Metastatic Colorectal Cancers in Turkish Patients

  • Gorukmez, Orhan;Yakut, Tahsin;Gorukmez, Ozlem;Sag, Sebnem Ozemri;Karkucak, Mutlu;Kanat, Ozkan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1175-1179
    • /
    • 2016
  • The results of this study demonstrate the potential prognostic and predictive values of KRAS and BRAF gene mutations in patients with colorectal cancer (CRC). It has been proven that KRAS and BRAF mutations are predictive biomarkers for resistance to anti-EGFR monoclonal antibody treatment in patients with metastatic CRC (mCRC). We demonstrated the distribution of KRAS (codons 12, 13 and 61) and BRAF (codon 600) gene mutations in 50 mCRCs using direct sequencing and compared the results with clinicopathological data. KRAS and BRAF mutations were identified in 15 (30%) and 1 (2%) patients, respectively. We identified KRAS mutations in codon 12, 13 and 61 in 73.3% (11/15), 20% (3/15) and 6.67% (1/15) of the positive patients, respectively. The KRAS mutation frequency was significantly higher in tumors located in the ascending colon (p=0.043). Thus, we found that approximately 1/3 of the patients with mCRC had KRAS mutations and the only clinicopathological factor related to this mutation was tumor location. Future studies with larger patient groups should yield more accurate data regarding the molecular mechanism of CRC and the association between KRAS and BRAF mutations and clinicopathological features.

Reviewing the fireproofing of lightweight aerataed concrete for fire door interior cores (방화문 내부 심재용 경량기포콘크리트의 방화성 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.43-44
    • /
    • 2023
  • Fire doors installed to prevent the spread of fire in buildings are made of paper honeycomb, glass wool, and other materials. Due to their high water absorption rate, they absorb ambient moisture and degrade, and their increased weight causes them to sag internally, creating voids that can warp in the event of a fire and allow flames to pass through. To overcome these issues, research is being conducted on the physical performance of lightweight aerated concrete. However, there is a lack of research on how to ensure fire resistance. Therefore, in this study, the backside temperature of lightweight aerated concrete formulations was measured and compared and analyzied with the physical performance. Since it is difficult to achieve low density by saturation alone, aerated concrete with EPS was produced, which resulted in a density reduction of 24'26%, but the strength increase per unit cement increase was 5'25%, which tended to be lower than the formulation without EPS. The results showed that the lightweight aerated concrete with EPS was 130~140℃ lower than the lightweight aerated concrete with EPS, which is believed to be due to the melting point of EPS delayed the heat diffusion. In the future, wo plan to conduct research to identify the optimal formulation for fire door core materials by varying the amount of EPS added and using industrial by-products to increase long-term strength.

  • PDF