• Title/Summary/Keyword: Safety drop zone

Search Result 8, Processing Time 0.025 seconds

Data-based Traffic Safety Strategy for Sejong City (데이터 기반의 세종시 교통안전망 강화 방안 연구)

  • Kang, Hyun-Jung;Kim, Taehong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.147-149
    • /
    • 2021
  • The trend of increasing traffic problems due to the explosion in traffic volume in Sejong City has reached a level that cannot be solved by investment in facility infrastructure, so it is essential to establish an intelligent traffic environment based on data. By benchmarking similar cases in the domestic and overseas, and analyzing the traffic information of Sejong City, we propose a plan to provide parking information using Intelligent CCTV, a smart traffic signal control system, and a safe drop zone. It is expected that this study will a basis for establishing policies of the Sejong City traffic safety strategy in the future.

  • PDF

Centrifuge modeling of dynamically penetrating anchors in sand and clay

  • An, Xiaoyu;Wang, Fei;Liang, Chao;Liu, Run
    • Geomechanics and Engineering
    • /
    • v.30 no.6
    • /
    • pp.539-549
    • /
    • 2022
  • Accidental anchor drop can cause disturbances to seabed materials and pose significant threats to the safety and serviceability of submarine structures such as pipelines. In this study, a series of anchor drop tests was carried out to investigate the penetration mechanism of a Hall anchor in sand and clay. A special anchor drop apparatus was designed to model the inflight drop of a Hall anchor. Results indicate that Coriolis acceleration was the primary cause of large horizontal offsets in sand, and earth gravity had negligible impact on the lateral movement of dropped anchors. The indued final horizontal offset was shown to increase with the elevated drop height of an anchor, and the existence of water can slow down the landing velocity of an anchor. It is also observed that water conditions had a significant effect on the influence zone caused by anchors. The vertical influence depth was over 5 m, and the influence radius was more than 3 m if the anchor had a drop height of 25 m in dry sand. In comparison, the vertical influence depth and radius reduced to less than 3 m and 2 m, respectively, when the anchor was released from 10 m height and fell into the seabed with a water depth of 15 m. It is also found that the dynamically penetrating anchors could significantly influence the earth pressure in clay. There is a non-linear increase in the measured penetration depth with kinematic energy, and the resulted maximum earth pressure increased dramatically with an increase in kinematic energy. Results from centrifuge model tests in this study provide useful insights into the penetration mechanism of a dropped anchor, which provides valuable data for design and planning of future submarine structures.

The Experimental Study of Safety and Efficacy in Using Bovis Calculus Pharmacopuncture Solution as Eye Drop (점안용 우황약침액의 안전성 및 유효성 평가)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.3
    • /
    • pp.61-72
    • /
    • 2009
  • Objectives : This experimental study was performed to investigate the safety and efficacy of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. To identify the use of it as eye drop, the eye irritation test of rabbits and the antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans were performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Bovis Calculus pharmacopuncture solution on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Bovis Calculus pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Bovis Calculus pharmacopuncture solution was medicated. Conclusions : The present study suggests that Bovis Calculus pharmacopuncture solution is a nontoxic and non-irritant medicine, which does not cause eye irritation in rabbits, but dosen't have antibacterial effects on bacterial species(Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

The Proper Length of Transition Area for Work Zones on Urban Freeways (도시고속도로 공사구간의 적정 완화구간 길이 산정)

  • Lee, Mi Ri;Lee, Chungwon;Kim, Do-Gyeong
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.4
    • /
    • pp.58-66
    • /
    • 2013
  • Due to the characteristics of urban freeways such as heavy traffic and high speed, work zone on urban freeways causes the increase of not only the likelihood of crash occurrence but also traffic congestion caused by lane drop, lane change, acceleration/deceleration, and etc. This paper aims to determine the proper length of transition area that satisfies two criteria, mobility and safety, to make the operation of work zone more efficient. For the analysis, three different scenarios were developed by the number of lanes and the proper length of transition area were determined by changing the length from 100m to 500m in 100m increments. The results showed that the proper length of transition area for 3- and 4-lane freeways is 300m, whereas the proper length of 2-lane freeways is 200m. The results indicated that the different length of transition area based on the number of lanes is more desirable and efficient.

The Experimental study of safety and efficacy in using Soyeom Pharmacopuncture solution as eyedrops (점안용 소염약침액의 안전성 및 유효성 평가)

  • Kang, Eun-Kyo;Seo, Hyung-Sik
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.21-33
    • /
    • 2009
  • Objective : This experimental study was performed to investigate the safety of Soyeom Pharmacopunture solution manufactured by extraction of alcohol and water. To identify the use of it as eyedrops, the eye irritation test of rabbits and antibacterial test of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans was performed. Methods : 1. The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Soyeom pharmacopuncture solution was administered in the left eye of the rabbits, eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 2. After administering Soyeom Pharmacopuncture solution on bacterial species (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) which cause Keratitis, MIC(Minimum Inhibition Concentration) and the size of inhibition zone were measured. Anti-bacterial potency was also measured using the size of inhibition zone. Results : 1. After Soyeom pharmacopuncture solution was administered in the left eye of the rabbits, it was found that none of nine rabbits have abnormal signs and weight changes. 2. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, no eye irritation of the cornea, iris and conjunctiva was observed at 1, 2, 3, 4 & 7day. 3. There was no response to MIC on bacterial species (Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, Candida albicans) after Soyeom pharmacopuncture solution was medicated. Conclusions : The present study suggests that Soyeom pharmacopuncture solution is a non-toxic and non-irritant medicine, which does not cause eye irritation in rabbits, but dosen't have anti-bacterial effects on bacterial species which cause Keratitis. These study result recommends that more research on other herbal medicines of eye drop for Keratitis are required.

Simulation study on effects of loading rate on uniaxial compression failure of composite rock-coal layer

  • Chen, Shao J.;Yin, Da W.;Jiang, N.;Wang, F.;Guo, Wei J.
    • Geomechanics and Engineering
    • /
    • v.17 no.4
    • /
    • pp.333-342
    • /
    • 2019
  • Geological dynamic hazards during coal mining can be caused by the failure of a composite system consisting of roof rock and coal layers, subject to different loading rates due to different advancing velocities in the working face. In this paper, the uniaxial compression test simulations on the composite rock-coal layers were performed using $PFC^{2D}$ software and especially the effects of loading rate on the stress-strain behavior, strength characteristics and crack nucleation, propagation and coalescence in a composite layer were analyzed. In addition, considering the composite layer, the mechanisms for the advanced bore decompression in coal to prevent the geological dynamic hazards at a rapid advancing velocity of working face were explored. The uniaxial compressive strength and peak strain are found to increase with the increase of loading rate. After post-peak point, the stress-strain curve shows a steep stepped drop at a low loading rate, while the stress-strain curve exhibits a slowly progressive decrease at a high loading rate. The cracking mainly occurs within coal, and no apparent cracking is observed for rock. While at a high loading rate, the rock near the bedding plane is damaged by rapid crack propagation in coal. The cracking pattern is not a single shear zone, but exhibits as two simultaneously propagating shear zones in a "X" shape. Following this, the coal breaks into many pieces and the fragment size and number increase with loading rate. Whereas a low loading rate promotes the development of tensile crack, the failure pattern shows a V-shaped hybrid shear and tensile failure. The shear failure becomes dominant with an increasing loading rate. Meanwhile, with the increase of loading rate, the width of the main shear failure zone increases. Moreover, the advanced bore decompression changes the physical property and energy accumulation conditions of the composite layer, which increases the strain energy dissipation, and the occurrence possibility of geological dynamic hazards is reduced at a rapid advancing velocity of working face.

Studies of the egg drop laying diseases from the mass zone layer (산란계 밀집지역의 산란저하성 질병에 관한 연구)

  • Lee Jeoung-Won;Eum Sung-Shim;Park In-Gyu;Bea Joung-Jun;Joung Dong-Suk;Song Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.2
    • /
    • pp.121-146
    • /
    • 2005
  • Newcastle disease (ND), infectious bronchitis (IB), low pathogenic avian Influenza (LPAI) and fowl typhoid (FT) have been known as egg drop laying diseases because of the serious layer damage from mass zone layer. In this study, such egg drop laying diseases were investigated. To access this study, we peformed to evaluate antibody titers in serum and isolated bacteria and virus from organs and feces on May, July and September in 2003. The distribution of ND from January to May, IB and LPAI from October to February of the next year, and FT from March to September were inspected by the question survey in 21 farms. ND revealed to be positive rates of 490 to 474 $(96.7\%)$ in May, 510 to 506 $(99.2\%)$ in July and 510 to 510 $(100\%)$ in September with hemagglutination inhibition (HI) test. The mean antibody titers were 10.2, 9.9 and 10.2, respectively. With regard to IB, 484 out of 490 samples $(98.7\%)$ in May, 508 of 510 $(99.6\%)$ in July and 509 of 510 $(99.8\%)$ in September showed positive results and the mean antibody titers were gradually increased with 8.2, 9.0 and 9.4, respectively. According to HI test of LPAI, the positive results were shown in 442 of 480 $(92.1\%)$, 394 of 494 $(79.8\%)$ and 402 of 483 $(83.2\%)$ in May, July and September, respectively The mean antibody titers were decreased with 4.6, 4.3 and 4.0. The distribution of LPAI also elicited the positive rates of 480 to 475 $(99.0\%)$ in May, 494 to 485$(98.2\%)$ in July, 483 to 472 $(97.7\%)$ in September as determined by ELISA and the mean S/P ratio were 2.319, 2.557 and 2.380, respectively. Compared ELISA results with HI test of LPAI the positive results were 480 to 422 $(92.1\%),\;475(99.0\%),\;494\;to\;394 (79.8\%),\;485 (98.2\%)\;and\;483\;to\;402(83.2\%),\;472(97.7\%)$. Therefore, the positive rate determined by ELISA was higher than that of HI test with 6.9, 18.4 and $14.5\%$, respectively. When performed RT-PCR for ND using organ and feces samples, the pathotypes were detected $5(15.6\%)\;in\;May,\; 2(5.3\%) in\;July,\;2(7.1\%)$ in September but there is no samples showing positive band for LPAI. In attempt to isolate Salmonella gallinarum, bacteria were obtained from 4 cases (12.5%) in May, 9 (23.6%) in July, 5 (17.8%) in September. Thus the highest rate for isolation revealed to be shown in July When evaluated the antimicrobial susceptibility to 18 isolated strains of 5. gallinarum, bacteria were sensitive to trimethoprim/sulfamethox$(61.1\%),\;kanamycin\;(55.5\%),\;ampicillin\;(55.5\%)$ and amoxacillin/clavulanic acid $(55.5\%)$, cephalothin $(50.0\%)$, but resistant to penicillin $(88.9\%)$, streptomycin $(88.9\%)$, erythromycin $(83_4\%)$ and tetracycline $(61.1\%)$. According to HI test of ND and LPAI using captured 164 wild Korean tree sparrows (Passer nontanus), the positive rates were $47.6\%\;and\;57.3\%$, and the mean HI titers were 5.32 and 4.02, respectively. 71 $(43.2\%)\;and\;58(35.3\%)$ in captured sparrows also showed more than 4 titers for HI test to ND and LPAI, respectively However, the attempt for isolation of viruses failed in all samples.

Evaluation of Fracture Toughness in Steel Weldment for Inner Wall of LNG Storage Tank (LNG 저장탱크 내조용 강 용접부의 파괴인성 평가)

  • Jang J.-i.;Ju J.-B.;Yang Y.-c.;Kim W.-s.;Hong S. H.;Kwon D.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 1998
  • In this study, for the safety performance of LNG storage tank, the fracture toughness in X-grooved weld HAZ(heat-affected zone) of $9\%$ Ni steel was evaluated qualitatively and quantitatively, and the relation with the change in microstructure was analyzed. The toughness assessment was peformed through the modified CTOD test proposed for thick weldment with X-groove. Additionally, microstructures of HAZ were evaluated by OM, SEM and XRD. From the results, HAZ toughness of SMA(shielded metal arc)-welded $9\%$ Ni steel decreased as the evaluated region approached the fusion line. The decrease in toughness was apparently caused by the increase in the fraction of coarse-grained zone within HAZ. On the other hand, toughness drop with decreasing test temperature in F.L.(fusion line) ${\~}$F.L.+3mm was larger than that in F.L.+5mm${\~}$F.L.+7mm region due to the fact that in the former regions, retained austenite had poor stability.

  • PDF