• Title/Summary/Keyword: Safety and Health Register

Search Result 15, Processing Time 0.02 seconds

The study on bibliography register basis and Revision plan about origin that 'The 11 established formularies of Korean traditional herbal medicine volumes' (기성한약서(旣成韓藥書) 11종의 기원(起源)에 대한 서지학적(書誌學的) 근거(根據)와 개정(改正) 방안(方案)에 대한 연구(硏究))

  • Shin, Hyun-Gyu;Whang, Dae-Sun;Kweon, Sam-Su;Kim, Yong-Jin
    • Journal of Korean Medical classics
    • /
    • v.20 no.1
    • /
    • pp.103-111
    • /
    • 2007
  • 1. "Regulation for about kind of formularies of Korean traditional herbaland preparation method"(Ministry of Health and Welfare No. 1995-15, 95. 3. 15) and "Regulation for review safety and efficacy of drugs. Article 2. 1 Clause 10." should revise "Sasanguihak(四象醫學)" by "Donguisusebowon(東醫壽世保元)" that is the name of book. 2. "Regulation for review safety and efficacy of drugs. Article 2. 1 Clause 10." was defining 'The 11 established formularies of Korean traditional herbal medicine volumes' "Donguisusebowon" that is defined as "The 11 established formularies of Korean traditional herbal medicine volumes" is "Susebowon(壽世保元)" that the Ming period Gong jung-hyun writes. Otherwise, mistake that "Donguisusebowon" of Lee Jema(李濟馬) was recorded 2 times occurs. Therefore, "Susebowon" of "The 11 established formularies of Korean traditional herbal medicine volumes" is that "Susebowon" of the Ming period Gong Jung-hyun writes 3. "yaksungga(藥性歌)" is nonbook in "The 11 established formularies of Korean traditional herbal medicine volumes" and should be erase. Because basis is ambiguous. 4. "The 11 established formularies of Korean traditional herbal medicine volumes" must revise by 10 kinds in "Regulation for about kind of formularies of Korean traditional herbaland preparation method" and "Regulation for review safety and efficacy of drugs. Article 2." The kinds should be revised by "Donguibogam(東醫寶鑑)", "jejungsinpyeon(濟衆新編)", "Euihakipmoon(醫學入門)", "kyungakjeonse(景岳全書)", "Susebowon", "Bonchogangmok(本草鋼目)", "Bangyakhappyeon(方樂合編)", "Hyangyakjipseongbang(鄕樂集成方)", "Gwangjebigeup" and "Donguisusebowon".

  • PDF

OHSAS Practices Analysis : A Case Study using Audit Results (안전보건경영시스템 운용분석 : 심사자료 사례연구)

  • Park, Dong-Joon;Kang, Byung-Hwan;Kim, Ho-Gyun
    • Korean Management Science Review
    • /
    • v.32 no.2
    • /
    • pp.79-89
    • /
    • 2015
  • The firms with OHSAS (Occupational Health and Safety Management System) registration should be audited every six months and they have to be reregistered every three years by a third party. In our article audit data were collected from the audit processes of fifty four firms that OHSAS 18001:2007 was implemented and audited by LRQA (Lloyd's Register Quality Assurance). Fifty four firms are largely classified as four categories: civil engineering and construction industry, metal and heavy industry, chemical industry, and other industries including electric, electronic, food, and services. Especially the minor conformity data are analyzed by statistical methods to find out the relationship between four categories of 54 firms and the average number of minor nonconformities. The most frequently appeared minor nonconformities among sub-requirements of OHSAS 18001:2007 are investigated and the reasons for minor nonconformities are specifically explained. The average number of minor nonconformities of firms before and after OHSAS 18001:2007 registration are compared to understand the maturity of OHSAS implementation. Some comments and suggestions are provided for OHSAS to be effectively implemented to the firms if revision is necessary.

Breast Cancer Survival at a Leading Cancer Centre in Malaysia

  • Abdullah, Matin Mellor;Mohamed, Ahmad Kamal;Foo, Yoke Ching;Lee, Catherine May Ling;Chua, Chin Teong;Wu, Chin Huei;Hoo, LP;Lim, Teck Onn;Yen, Sze Whey
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8513-8517
    • /
    • 2016
  • Background: GLOBOCAN12 recently reported high cancer mortality in Malaysia suggesting its cancer health services are under-performing. Cancer survival is a key index of the overall effectiveness of health services in the management of patients. This report focuses on Subang Jaya Medical Centre (SJMC) care performance as measured by patient survival outcome for up to 5 years. Materials and Methods: All women with breast cancer treated at SJMC between 2008 and 2012 were enrolled for this observational cohort study. Mortality outcome was ascertained through record linkage with national death register, linkage with hospital registration system and finally through direct contact by phone or home visits. Results: A total of 675 patients treated between 2008 and 2012 were included in the present survival analysis, 65% with early breast cancer, 20% with locally advanced breast cancer (LABC) and 4% with metastatic breast cancer (MBC). The overall relative survival (RS) at 5 years was 88%. RS for stage I was 100% and for stage II, III and IV disease was 95%, 69% and 36% respectively. Conclusions: SJMC is among the first hospitals in Malaysia to embark on routine measurement of the performance of its cancer care services and its results are comparable to any leading centers in developed countries.

The Efficacy of P2Y12 Reactive Unit to Predict the Periprocedural Thromboembolic and Hemorrhagic Complications According to Clopidogrel Responsiveness and Safety of Modification of Dual Antiplatelet Therapy : A Meta-Analysis

  • Kim, Hyun Jung;Oh, Jae Sang;Park, Sukh Que;Yoon, Seok Mann;Ahn, Hyeong Sik;Kim, Bum Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.539-549
    • /
    • 2020
  • The efficacy of P2Y12 reaction unit (PRU) of VerifyNow still remains as a controversial issue in neurointervention. So we investigated the usefulness of PRU of VerifyNow to predict the peri-procedural thromboembolic events (TE) and hemorrhagic events (HE). And we evaluated the safety of modified dual antiplatelet therapy (DAPT) or triple antiplatelet therapy (TAPT) for clopidogrel hyporesponders. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Web of Science and Scopus on August 19 2018. Data was collected the 1) incidence of TE between clopidogrel responder and clopidogrel hypo-responder, 2) incidence of HE between clopidogrel hyper-responder and clopidogrel responder and hypo-responder, and 3) incidence of TE and HE between modified DAPT or TAPT and standard DAPT in clopidogrel hypo-responder. High cut-off value of PRU was defined as PRU >40% or <220. Fifteen studies were enrolled. Clopidogrel responder showed lower incidence of TE than hypo-responder (risk ratio [RR], 0.32; 95% confidence interval [CI], 0.17-0.61; p<0.001). With the high cut-off value of PRU, clopidogrel responder showed more lower incidence of TE than hypo-responder (RR, 0.11; 95% CI, 0.02-0.45; p=0.002). The incidence of periprocedural HE have higher on clopidogrel hyper-responder than clopidogrel responder and hypo-responder (RR, 4.26; 95% CI, 1.10-16.44; p=0.04; I2=66%). The incidence of periprocedural TE after changing regimen of DAPT for clopidogrel hypo-responder have a tendency to reduce, but there was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). The incidence of periprocedural HE after changing regimen of DAPT for clopidogrel hypo-responder was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). PRU is a useful tool as a predictor of peri-procedural TE or HE on neurointervention. PRU has a threshold effect of cut-off value to predict the peri-procedural TE. Modified DAPT or TAPT to prevent TE in clopidogrel hypo-responders could not reduce the incidence of TE. We should investigate the further research about modification of regiment on neurointervention.

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.