• Title/Summary/Keyword: Safety and Health Levels

Search Result 901, Processing Time 0.025 seconds

Evaluation of Lead Exposure Characteristics Using Domestic Occupational Exposure Literature Data (납에 대한 국내 직업적 노출 문헌 자료 고찰을 통한 노출 특성 평가)

  • Choi, Sangjun;Seo, Sung Chul;Park, Ju-Hyun;Koh, Dong-Hee;Kim, Hwan-Cheol;Park, Donguk;Choi, Hee Eun;Sung, Yeji;Oh, Se-Eun;Ko, Kyoung Yoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Objectives: The purpose of this study is to evaluate exposure characteristics of lead using data from the domestic occupational exposure literature. Methods: Occupational airborne exposure data on lead reported in the domestic literature from 1981 to 2018 were collected and re-analyzed. The exposure levels in the data were expressed as an estimated arithmetic mean and a weighted arithmetic mean (WAM) of the number of samples. Lead exposure characteristics were analyzed by industry, process, and year. Results: From a total of 14 documents, 8,305 airborne lead measurements for 17 industries were identified, and the WAM concentration in eight industries exceeded the occupational exposure limit of 50 ㎍/m3. Three industries (battery manufacturing, lead smelting, and litharge manufacturing) accounted for 95% of the total data, and exposure trends could be confirmed over 10 years. Exposure levels continue to decrease in all three industries. Conclusions: Considering the distribution outlook of lead and lead compounds, the main management targets are lead storage battery manufacturing and secondary smelting for lead regeneration.

Characterization of X-ray Emitted in the Ion Implantation Process of Semiconductor Operations (반도체 제조 이온주입 공정의 이온 임플란타 장치에서 엑스레이 발생 특성)

  • Dong-Uk Park;Kyung Ehi Zoh;Soyeon Kim;Seunghee Lee;Eun Kyo Jeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.439-446
    • /
    • 2023
  • Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.

Occupational Exposure to Chemicals for Workers and Levels of Airborne Chemicals in Hairdressing Salon (미용실 작업자의 화학물질에 대한 직업적인 노출과 실내공기오염 수준)

  • Yun, Jung Soon;Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.375-384
    • /
    • 2006
  • Hairdressers may be exposed to many chemicals from hair dye, permanent, shampoo, hair spray and so on. The study was conducted to evaluate occupational exposure to 8 chemicals (isopropanol, ethanol, xylene, toluene, ethylbenzene, acetone, ammonia and formaldehyde) for workers and levels of these materials in airborne of a hairdressing salon. Since compared to ACGIH TLVs these 8 chemicals were very low, it is thought that there has no problem to occupational exposure to these chemicals. Even if hairdressing salon is not enforced on Korean Standards for Indoor Air Quality, level of TOVC was thought to be below the standards. At the aspect of indoor air quality formaldehyde needs to be controlled in the future. The results imply that emission of isopropanol, ethanol, acetone and ammonia are related with hairdressing job, but emission of xylene, toluene and ehtylbenzene is more related with traditional indoor air pollution than hairdressing job. Sources of formaldehyde is thought to be little related with hairdressing job. HVAC system was a little effective on general ventilation.

Clinical characteristics and nursing diagnoses of pediatric patients hospitalized with inflammatory bowel disease: a single-center retrospective study in South Korea

  • Sung-Yoon Jo;Kyung-Sook Bang
    • Child Health Nursing Research
    • /
    • v.29 no.3
    • /
    • pp.218-228
    • /
    • 2023
  • Purpose: This study aimed to identify clinical characteristics of South Korean pediatric inflammatory bowel disease (IBD) in a children's hospital over the past 5 years, with a specific focus on comparing the features observed between Crohn's disease (CD) and ulcerative colitis (UC). Additionally, it aimed to examine the nursing diagnoses given to patients. Methods: This retrospective study analyzed the medical records of Korean pediatric patients under 18 years of age who were diagnosed with IBD and hospitalized at a children's hospital in Seoul, South Korea, from January 2017 to December 2021. Results: The number of pediatric patients diagnosed with IBD steadily increased. This finding was particularly prominent for CD patients, the majority of whom were male. Pediatric patients with CD had significantly higher rates of abdominal pain and perianal lesions, while pediatric patients with UC had a higher rate of bloody stool. Laboratory findings indicated that CD patients had higher levels of inflammatory markers and lower albumin levels than UC patients. The nursing diagnoses given during hospitalization mostly related to safety and protection, physical comfort, and gastrointestinal function. Conclusion: This study provides insights into Korean pediatric IBD patients, enabling early detection and the development of nursing intervention strategies. From a comprehensive perspective, nursing care should not only address patients' physical needs but also their psychosocial needs.

Evaluation of Quality Management of Domestic Asbestos Survey and Monitoring Service Providers (국내 석면조사기관의 품질관리 수준에 대한 평가)

  • Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • Objectives: The aim of this study is to evaluate the quality management systems of domestic asbestos survey and monitoring service providers and the relationships with the number of licenses or designations and sales performances. Methods: Data on quality management systems were collected by assessors who were assigned by the Korea Occupational Safety and Health Agency(KOSHA) during a pilot evaluation program for designated asbestos survey and monitoring service providers in 2016 using evaluation criteria developed by KOSHA. Basic characteristics, evaluated scores, and sales performance were gathered and statistically analyzed. Results: The median and arithmetic mean of the total scores were 0.64 and 0.66. Evaluation fields that scored highly with the highest percentages were sales performance, installation and availability of equipment, compliance with the mandatory minimum number of airborne samples, laboratory independence, and results of proficiency analytical testing, in that order. Evaluation fields that received low marks with the highest percentages were the training of personnel, blank field samples, calibration of flow rates, preliminary check and visual inspection of the work area prior to the clearance test, and review and approval of final reports, in that order. Comparison of normalized scores between service providers registered for asbestos and other tasks and those designated for only asbestos showed significant differences in their evaluated scores. Sales performance did not show a positive correlation with evaluated scores. Conclusions: The quality management systems of domestic asbestos survey and monitoring service providers were poor. High scores were recorded mostly in evaluation fields related to regulatory requirements. Low scores were recorded mostly in evaluation fields related to documentation and recordkeeping. Considering the low influence of quality on sales performance, the government needs to evaluate the quality management of asbestos survey and monitoring service providers and provide the results to public in order to address their low levels of quality management.

Reconstruction of the Korean Asbestos Job Exposure Matrix

  • Kang, Dongmug;Jung, Saemi;Kim, Yun-Ji;Kim, Juyoung;Choi, Sangjun;Kim, Se Yeong;Kim, Youngki
    • Safety and Health at Work
    • /
    • v.12 no.1
    • /
    • pp.74-95
    • /
    • 2021
  • Background: A job-exposure matrix (JEM) is an important surrogate indicator to evaluate past exposure levels. Although a Korean asbestos JEM has been constructed previously, this JEM includes only a few industrial and occupational groups. This study aimed to reconstruct the JEM by integrating the latest organized data to improve its utility. Methods: We used recent Korean standard industry and occupation codes and extracted 36 articles from a systematic literature review to initiate the reconstruction of the previous Korean asbestos JEM. The resulting data consisted of 141 combinations of industrial and occupational groups. Data from the Netherlands's JEM were also reviewed and categorized into 70 industrial and 117 occupational groups by matching with the Korean data. We also utilized Germany's data, which consisted of 10 industrial and 14 occupational groups. Results: The reconstructed Korean asbestos JEM had 141 combinations of industries and occupations. The time periods are from the 1980s to the 2000s in 10-year intervals. Most of the data were distributed between the 1990s and the 2000s. Occupations with high exposure to asbestos included knitting and weaving machine operators, automobile mechanics or assemblers, ship mechanics or assemblers, mineral ore and stone products processing mechanics, and metal casting machine operators or mold makers. Conclusions: The reconstructed Korean asbestos JEM has expanded the type and duration of the occupational groups of the previous JEM and can serve as an important reference tool for evaluating asbestos exposure and designing compensation and prevention policies in Korea.

The Effects of Ecklonia stolonifera Extracts on Improvement of Hepatic Function: a Double-Blind, Randomized, Placebo-Controlled Clinical Study (곰피추출물의 간기능 개선 효과 평가를 위한 12주, 무작위배정, 이중맹검, 위약-대조 인체적용시험)

  • Kim, Junghee;Kim, Eun Jin;Kang, Dahye;Kim, Hyung-Bin;Jang, Jae Young;Om, Ae-Son;Kim, Jongwook
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.198-205
    • /
    • 2022
  • Hepatic diseases are divided into two types: alcoholic and non-alcoholic. Non-alcoholic liver injury finally induces fatty liver and damages liver function. Many studies have demonstrated that Ecklonia stolonifera has antioxidative, anti-inflammatory, and hepatoprotective activities. We conducted a 12-week double-blind, placebo-controlled, randomized trial to examine the efficacy of E. stolonifera extracts (ESE) on biochemical markers of hepatic function. Sixty-five subjects with mild or moderate liver injuries were randomly allocated to receive either 420 mg/d of ESE or a placebo for 12 weeks. Fifty-five participants completed the trial. No significant adverse events were observed among the subjects during the study. The primary end points were changes in plasma levels of aspartate transaminase (AST), alanine transaminase (ALT), and γ-glutamyltransferase (γ-GT). The secondary end points were changes in lipid profile levels, including total cholesterol (TC), triglyceride (TG), high-density lipoprotein cholesterol (HDL), and low-density lipoprotein cholesterol (LDL). Compared with the baseline, AST and ALT levels decreased significantly in the ESE group compared to those in the placebo group (P<0.001). In addition, γ-GT levels in the ESE group were significantly lower than those in the placebo group (P=0.016). There were no differences in the TC, TG, HDL, and LDL levels between groups. In conclusion, ESE consumption for 12 weeks improved liver parameters in subjects with liver injury. Regular consumption of ESE could maintain liver health in individuals at risk of hepatic damage.

A Study on the Status and Prediction of Arterial Road Noise in Seoul, Korea (서울시 간선도로의 소음도 현황 및 예측식에 관한 고찰)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Hong, Seung-Cheol;Choi, Joon-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.5
    • /
    • pp.395-402
    • /
    • 2008
  • Road traffic noise causes considerable disturbance and annoyance in exposed inhabitants. Particularly, arterial road noise is a significant environmental problem in many urban areas in which higher traffic volume and higher car speed occur. Arterial road noise became the target of this investigation in Seoul, South Korea. Noise levels were measured at four points that were based on distance from roadside at the same measurement site and under the conditions as reported by the National Institute of Environmental Research (NIER) in 1999. The average noise levels ($L_{eq,1h}$) of the arterial road was 80.3 dBA at 5 m, 77.4 dBA at 10 m, 73.7 dBA at 20 m, 70.9 dBA at 30 m. A comparison between 1999 and 2008's measurement values has shown that in 2008 noise level is up by about 1.5 dBA, traffic volume has increased by about 15.7%, while car speed has decrease by about 8%. The relationship between 2008' measured values and predicted values using the NIER Equation is low under 10 m from the roadside. The influence range of arterial noise is calculated at 26 m for road noise limits in daytime. In relation to the comparison between traffic volume and noise level, the equivalence in traffic volume (Light car+10xHeavy car) is higher than other variables.

Occupational Radiation Exposure of Emergency Medical Technicians in Emergency Medical Centers in Korea (우리나라 응급의료센터 응급구조사의 직업적 방사선 노출)

  • Lee, Hyeongyeong;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.170-179
    • /
    • 2017
  • Objectives: This study aims to investigate the occupational radiation exposures of emergency medical technicians(EMTs) in emergency medical centers in Korea. The results will provide a basis for developing prevention programs to minimize adverse health effects relating to radiation exposure among emergency medical technicians working in this area. Methods: Radiation exposure doses were measured for twenty-two EMTs working in six emergency medical centers. Thermo Luminescent Dosimeters(TLD) were placed on three representative body parts, including chest, neck, and a finger. Measurements were conducted over the entire working hours of the participants for foor weeks. Dosimeters were analyzed according to a standard method by a KFDA-designated lab. Detection rate, annual radiation exposure dose, and relative levels to dose limit were derived based on the measured doses from the dosimeters. SPSS/Win 18.0 software(IBM, US) was used for statistical analysis. Results: Detection rates were 45.5%, 36.4%, and 45.5% for the dosimeters sampled from chest, neck, and a finger, respectively. The average annual doses were $2.39{\pm}3.44mSv/year$(range 0.38-10.0 mSv/year) for the chest, $2.72{\pm}3.05mSv/year$(2.00-11.34) for the neck, and $20.98{\pm}17.57mSv/year$(1.25-53.50) for the hand dose. The average annual eye dose was estimated to $3.61{\pm}2.37mSv/year$(1.50-8.34). The exposure dose levels of EMTs were comparable to those of radiologists, who showed relatively higher radiation dose among health care workers, as reported in another study. Conclusions: EMTs working in emergency medical centers are considered to be at risk of radiation exposure. Although the radiation exposure dose of EMTs does not exceed the dose limit, it is not negligible comparing to other professionals in health care sectors.

Occupational Exposure to Potentially Infectious Biological Material Among Physicians, Dentists, and Nurses at a University

  • Reis, Leonardo Amaral;La-Rotta, Ehidee Isabel Gomez;Diniz, Priscilla Barbosa;Aoki, Francisco Hideo;Jorge, Jacks
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.445-451
    • /
    • 2019
  • Objective: The objective of this study was to evaluate the prevalence and incidence of accidents with biological material, the level of knowledge, and compliance to standard precautions (SPs) among dentists, physicians, nurses, and dental and medical students. Methods: A closed cohort study with a prospective and retrospective component was conducted between August 2014 and September 2015. The participants were contacted in two moments during the follow-up period, during which a structured questionnaire divided into six sections was used; the interviews were conducted during the follow-up period (Month 6) and at the end of the observation period (Month 12). Results: The global prevalence of accidents in the previous 12 months was 10.2%, with a difference between professionals and students (13.0% vs. 5.1%, respectively; p < 0.003). The incidence rate was 6.49 per 100 person/year, with difference between the groups (6.09 per 100 person/year in professionals and 7.26 per 100 person/year in students), type of specialization (hazard ratio, 3.27), and hours worked per week (hazard ratio, 2.27). The mean of compliance to SP was 31.99 (±3.85) points, with a median of 33 (30, 35) points against the expected 27.75 points. Adherence to SP was associated with the accident report (p < 0.020). Conclusion: We conclude that the proportion/incidence rate of accidents with biological material was high in relation to that in the literature, being higher in professionals and especially among physicians. The levels of knowledge and adherence to SP were good, with the best found in dentists and dental students.