• Title/Summary/Keyword: Safety Risk Assessment

Search Result 1,996, Processing Time 0.029 seconds

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Toxicity Test of Carbosulfan and Phenthoate on Killifish (Carbosulfan과 Phenthoate의 송사리(Oryzias latipes, Medaka)에 대한 독성시험)

  • Bae, Chul-Han;Lee, Jeong-Seok;Cho, Kyung-Won;Park, Hyun-Ju;Cho, Dong-Hun;Shin, Kwan-Seop;Jung, Chang-Kook;Park, Yeon-Ki
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.4
    • /
    • pp.309-318
    • /
    • 2004
  • Acute toxicity test and chronic toxicity test were conducted with killifish (Oryzias latipes, Medaka) to evaluate toxicity effect of pesticides. Acute toxicity test was investigated mortality in 48 hours and 96 hours after treatment, chronic toxicity test was examined with the early life stage of 30 days after hatching be started embryos of Medaka. The test substances were two pesticides, Carbosulfan and Phenthoate, applied to the paddy rice plant and well-known to the high fish toxicity. As the result of acute toxicity test, median concentration $(LC_{50})$ at 96 hours in Medata was Carbosulfan 0.102 mg/L and Phenthoate 0.167 mg/L, and Fish early life stage toxicity test was conducted on basis of the result of acute toxicity test and concluded from the investigation of hatching success, period of hatching, survival post hatching, length and weight of surviving fishes and abnormal fish. The results of early life stage toxicity test were represented by no observed effect concentration (NOEC), lowest observed effect concentration (LOEC) and maximum acceptable toxicant concentration (MATC). NOEC was Carbosulfan 0.0067ppm and Phenthoate 0.011ppm, LOEC of PCP-Na, Carbosulfan and Phenthoate were 0.017ppm and 0.029ppm, MATC of Carbosulfan and Phenthoate were 0.011ppm and 0.018ppm. These studies will be expected to supply more varied chronic toxicity effects at lower concentration than acute toxicity test. Therefore, evaluation data will be more realistic and the risk assessment of pesticide will be leveled up.

Multiplex PCR method for environmental monitoring of approved LM cotton events in Korea (국내 승인 LM면화의 자연환경 모니터링을 위한 multiplex PCR 개발)

  • Jo, Beom-Ho;Seol, Min-A;Shin, Su Young;Kim, Il Ryong;Choi, Wonkyun;Eum, Soon-Jae;Song, Hae-Ryong;Lee, Jung Ro
    • Journal of Plant Biotechnology
    • /
    • v.43 no.1
    • /
    • pp.91-98
    • /
    • 2016
  • The growth area of living modified (LM) cotton has steadily increased every year, since its first commercialization in 1996. Development of environmental risk assessment tools and techniques for LM cotton is required for ecosystem safety. We therefore developed multiplex PCR assays for simultaneous detection of two (MON15985, MON531) and four (GHB614, LLCOTTON25, MON88913 and MON1445) LM cotton events approved in Korea, with event specific primer pairs. The PCR reactions were optimized by using event specific primers of six LM cottons at various concentrations. The reactions allows amplification of estimated amplicons of MON15985 (214 bp), MON531 (270 bp), GHB614 (119 bp), LLCOTTON25 (164 bp), MON88913 (276 bp), and MON1445 (389 bp) from multiplex PCR reactions. The multiplex PCR assay developed allowed that two annealing steps (15 cycles at $55^{\circ}C$ and 25 cycles at $60^{\circ}C$) were performed for amplification of distinguished two LM cottons, and only one annealing step (50 cycles at $60^{\circ}C$) was necessary for tetraplex PCR. Primer extension step of all PCR reactions was skipped for time-effective amplification. Our methods suggest that two multiplex PCR assays can be cost-effective and a rapid diagnostic tool for environmental LMO monitoring of six LM cottons.

Monitoring of Polycyclic Aromatic Hydrocarbon Residues in Environmental Samples in Korea (국내 PAHs 오염 우려지역의 환경 시료 중 PAHs 잔류량 모니터링)

  • Lim, Jong-Soo;Kim, Seong-Soo;Park, Dong-Sik;Joo, Jin-Ho;Lim, Chun-Keun;Hur, Jang-Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.2
    • /
    • pp.95-105
    • /
    • 2007
  • The aim of this study was to determine the residual amounts of PAHs in environmental samples such as crop, soil and water collected from paddy, upland fields and forestlands near industrial zone and/or a thermal power plant in South Korea. All of the samples were analyzed by GC-mass spectrometer. The average contents of total PAHs in soil samples were 140.2 ${\mu}g\;kg^{-1}$ and the range was from 4.3 to $662.9{\mu}g\;kg^{-1}$. The detection of benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and dibenzo(a,h) anthracene which have strong carcinogenecity was ranged from 14.2 to 167.8 ${\mu}g\;kg^{-1}$. The residual amounts and detection frequency of PAHs in soil samples from the iron and heavy industrial areas near Pohang and Busan were 3-folds more than those of the other areas. Amounts of PAHs in upland soil samples was 1.5 folds higher than those of paddy soil samples, suggesting that it may be related to the content of organic matter in soil. The average contents of total PAHs in crop samples were 9.7 ${\mu}g\;kg^{-1}$ which ranged from 4.5 to 52.2 ${\mu}g\;kg^{-1}$. However, the residual amounts of PAHs in water samples were not detected. These results showed that soils and crops were slightly contaminated with PAHs. Therefore, the investigation should be continued for evaluating a safety or risk assessment through expansion of regions and crops.

Study on relationship between caffeine intake level and metabolic syndrome and related diseases in Korean adults: 2013 ~ 2016 Korea National Health and Nutrition Examination Survey (한국 성인의 카페인 섭취 수준이 대사증후군 및 관련 질환과의 관련성 연구 : 2013~2016 국민건강영양조사 자료 활용)

  • Lee, Jung-Sug;Park, Hyoung-Seop;Han, Sanghoon;Tana, Gegen;Chang, Moon-Jeong
    • Journal of Nutrition and Health
    • /
    • v.52 no.2
    • /
    • pp.227-241
    • /
    • 2019
  • Purpose: This study examined the relationship between caffeine intake and metabolic syndrome in Korean adults using the 2013 ~ 2016 Korea National Health and Nutrition Examination Survey data (KNHANES). Methods: The caffeine database (DB) developed by Food and Drug Safety Assessment Agency in 2014 was used to estimate the caffeine consumption. The food and beverage consumption of the 24 hr recall data of 2013 ~ 2016 KNHANES were matched to items in the caffeine DB and the daily caffeine intakes of the individuals were calculated. The sample was limited to non-pregnant healthy adults aged 19 years and older, who were not taking any medication for disease treatment. Results: The average daily caffeine intake was 41.97 mg, and the daily intake of caffeine of 97% of the participants was from coffee, teas, soft drinks, and other beverages. Multivariate analysis showed that the caffeine intake did not affect metabolic syndrome, hypertension, low HDL-cholesterol, and abdominal obesity. Diabetes and hypertriglyceridemia, however, were 0.76 (95% CI: 0.63 ~ 0.93), and 0.87 (95% CI: 0.77 ~ 0.98) in third quintile (Q3), and 0.66 (95% CI: 0.53 ~ 0.82) and 0.83 (95% CI: 0.73 ~ 0.94) in fourth quintile (Q4) compared to Q1, respectively. Therefore, caffeine intake of 3.66 ~ 45.81 mg per day is related to a lower risk of diabetes and hypertriglyceridemia. Conclusion: The study showed that adequate caffeine intake (approximately 45 mg) was associated with a lower prevalence of diabetes and hypertriglyceridemia. Therefore, it can be used as a guideline for the adequate level of caffeine intake for maintaining health.

Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image (드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun;Han, Eunjin;Kwon, Siyoon;Kim, Youngdo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.623-634
    • /
    • 2022
  • Due to river maintenance projects such as the creation of hydrophilic areas around rivers and the Four Rivers Project, the flow characteristics of rivers are continuously changing, and the risk of water quality accidents due to the inflow of various pollutants is increasing. In the event of a water quality accident, it is necessary to minimize the effect on the downstream side by predicting the concentration and arrival time of pollutants in consideration of the flow characteristics of the river. In order to track the behavior of these pollutants, it is necessary to calculate the diffusion coefficient and dispersion coefficient for each section of the river. Among them, the dispersion coefficient is used to analyze the diffusion range of soluble pollutants. Existing experimental research cases for tracking the behavior of pollutants require a lot of manpower and cost, and it is difficult to obtain spatially high-resolution data due to limited equipment operation. Recently, research on tracking contaminants using RGB drones has been conducted, but RGB images also have a limitation in that spectral information is limitedly collected. In this study, to supplement the limitations of existing studies, a hyperspectral sensor was mounted on a remote sensing platform using a drone to collect temporally and spatially higher-resolution data than conventional contact measurement. Using the collected spatio-temporal hyperspectral images, the tracer concentration was calculated and the transverse dispersion coefficient was derived. It is expected that by overcoming the limitations of the drone platform through future research and upgrading the dispersion coefficient calculation technology, it will be possible to detect various pollutants leaking into the water system, and to detect changes in various water quality items and river factors.