• Title/Summary/Keyword: Safety Guideline

Search Result 927, Processing Time 0.026 seconds

A Study on the Master Plan of Street Creation in Daedeok Science Culture (대덕과학문화의 거리 조성 기본계획에 관한 연구)

  • An, Se-Yun;Jeon, Jin-Bae;Kim, So-Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.262-271
    • /
    • 2018
  • Recently, Daejeon Metropolitan City is planning a futuristic city with Daedeok Special District at the center of its transformation into a city of nature, science and culture along with the fourth industrial revolution. Therefore, this research will divide the 1.5 km distance from the in Doryong-dong, Daejeon, science park intersection to the (Former)Daedeok Science and Culture Center, and propose a space design concept that incorporates IT technologies that fit the characteristics. The center will analyze the space status and derive an experience-oriented space design concept for user-centered planning so that it can serve as a guideline that will provide the fundamental direction for the promotion of the Daedeok Science Culture. Through the field survey, we will look for ways to integrate IT technology with infrastructure that needs improvement and change the distance of Daedeok Science culture as a smart street. The results of the field survey were : (1) made by connecting the persistence of comfort and safety issues, (2) uniformity and efficiency issues, and (3) the experience of identity problems and the orientation of the smart city. To create user-centered distances, we attempted to avoid uniform zoning based solely on infrastructure and zoning focusing on user behavior.

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

Improvement of Atmospheric PM2.5 Levels and Related Premature Deaths in Seoul, Korea (서울시 대기 중 PM2.5 농도 개선과 조기사망 감소 효과)

  • Bae, Hyun-Joo;Shin, JI-Young;Park, Chan-Koo;Jung, Kweon;Lee, Sang-Yol;Kim, Min-Young;Park, Jeong-Im
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • In recent studies, $PM_{2.5}$ has been reported to be more harmful to human health than $PM_{10}$ because it penetrates more deeply into the lung. We estimated $PM_{2.5}$ related health benefits in Seoul from implementing the World Health Organization (WHO)'s guidelines (annual average $10{\mu}g/m^3$, 24-hour average $25{\mu}g/m^3$) and U.S. Environmental Protection Agency (EPA)'s National Ambient Air Quality Standard (annual average $15{\mu}g/m^3$, 24-hour average $35{\mu}g/m^3$). U.S. EPA's Environmental Benefits Mapping and Analysis Program was utilized for the analysis. It was predicted that the attainment of the WHO annual guideline and U.S. EPA's annual standard, relative to the concentration in 2006, would result in reduction of 2,333~2,895 premature deaths and 1,703~2,121 premature deaths, respectively. If the WHO and EPA's daily standard for $PM_{2.5}$ are attained, 1,211~1,394 and 1,012~1,165 premature deaths could be avoided, respectively. Sensitivity analyses indicated that the estimates were robust regardless of air quality simulation methods for attaining the $PM_{2.5}$ goals. This study provides a quantitative approach to evaluate health risks from air pollution as well as to assess the potential health benefits of improving atmospheric $PM_{2.5}$ concentration. Even considering the intrinsic limitations and uncertainties of the analysis, it is an important information to rationalize the enforcement of $PM_{2.5}$ management policies and measures in Seoul, Korea.

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Analysis of Primary Internal and External Risk Factors According to the Accident Causes in Construction Site (건설현장의 사고원인에 따른 내·외부 리스크 핵심 요인 분석)

  • Yu, Yeong-Jin;Kim, Taehui;Son, Kiyoung;Lee, Kyoung-Hun;Kim, Ji-Myong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.519-527
    • /
    • 2016
  • The demand of construction risk analysis is rapidly increased to improve the competitiveness of construction companies and the sound management of the construction project. However, estimating the amount and uncertainty of the risk is difficult due to the wide range of risks in the construction industry. Moreover, most of the research on risk management of construction risk is only focused on the causes of risk without separate the internal and external risk. This study statistically analysis the internal risk and external risk based on the accidents cases which are caused at construction sites to define the difference and importances of the risk. An accident cause analysis and T-test analysis are carried out to reach the goal of study. The results of the study are expected to be used as a guideline of construction project risk analysis.

The study on application of automatic monitor system for initial fire suppression in double-deck tunnel (대심도 복층터널 초기화재 진압을 위한 자동모니터 소화설비의 적용성 연구)

  • Yoo, Yong-Ho;Park, Sang-Heon;Han, Sang-Ju;Park, Jin-Ouk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.419-429
    • /
    • 2016
  • In a bid to avoid the economic loss resulting from traffic jam in urban area, a deep underground road at 40 m depth has been considered and the first class disaster prevention facilities shall be applied according to domestic guideline. Automatic-monitoring fire extinguishing system designed to use for fire fighting has been widely applied at home and abroad. Recently development and commercialization through theoretical and experimental research to apply to road/railroad sector have been underway. Based on such performance of automatic fire extinguishing system, technical/economic analysis of existing water spray systems was conducted and as a result, it has demonstrated the superiority in terms of fire suppression as well as in cost efficiency. Then to commercialize this system, more diverse studies that will incorporate the characteristics of domestic tunnels are needed and should the system be promoted through institutional improvement, it's expected to become one of the advanced nations with own original technology in a life safety system industry throughout the world.

Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - III. Bacterial Reverse Mutation Testing of Hydrolyzed Whey Protein Powder Containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method - (Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - III. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말의 미생물복귀돌연변이시험 연구 -)

  • Kim, Hee-Kyong;Noh, Hye-Ji;Cho, Hyang-Hyun;Koh, Hong Bum
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2016
  • The ultimate research goal of the current study was a development of hydrolyzed whey protein powder (7%-GNANA) manufactured with normal content of sialic acid, a marker compound, that is naturally occurring at 7% concentration in GMP obtained from the milk protein. GMP is a safe food, used worldwide in infant and baby foods, etc. The test substance was prepared using (7% sialic acid containing) GMP as a raw material, and then using alcalase, an enzyme approved as a food additive, after separation of sialic acid with 100% efficiency and 7%-GNANA (containing 7% sialic acid and protein; product name: HELICOBACTROL-7) provided by MEDINUTROL Inc. (Korea). Bacterial reverse mutation (Ames) test was conducted in accordance with GLP Guideline using the test substance specified above. To identify its mutagenic potential against microorganisms, histidine auxotrophic strains of Salmonella Typhimurium, TA98, TA100, TA1535, and TA1537, and tryptophan auxotrophic strain of Escherichia coli, WP2uvrA, were used. The bacterial reverse mutation (Ames) test was performed by dividing the test substances into five different concentration groups (0, 61.7, 185, 556, 1,670, $5,000{\mu}g/plate$). Results of this experiment did not reveal repetitive increase of colony generating values or positive criteria for reverse mutagenicity for any concentration of test substances in any of the five strains, regardless of the presence of a metabolic activation system, and no dose-dependency was identified. In conclusion, the safety of 7%-GNANA test substance was verified by bacterial reverse mutation test conducted before registration of 7%-GNANA as a food additive.

Bacterial Reverse Mutation Test Evaluation of Hydrolyzed GMP Powder Containing Highly Concentrated Sialic Acid (23%) produced by Enzyme Separation and Solvent Enrichment Method (효소분리 및 용매정제법으로 제조한 고농도 Sialic Acid(23%)가 함유된 GMP 가수분해분말의 미생물복귀돌연변이시험 연구)

  • Kim, Hee-Kyong;Cho, Hyang-Hyun;Noh, Hye-Ji
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • The goal of this study was to develop hydrolyzed whey protein powder (23%-GNANA) manufactured with high content of sialic acid, a marker compound that is usually present at 7% concentration in GMP obtained from the milk protein. It is a safe food, used worldwide in infant and baby foods, etc. The test substance was prepared using (7% sialic acid containing) GMP as a raw material. Alcalase, an enzyme approved as a food additive, was used after separating sialic acid, with 100% efficiency, and 23%-GNANA (composed of 23% sialic acid and protein; product name: HELICOBACTROL-23), provided by MEDINUTROL Inc. (Korea), manufactured to have high (23%) content through ethanol soaking and enrichment. Bacterial reverse mutation (Ames) test was conducted in accordance with the GLP Guideline using the test substance specified above. To detect its mutagenicity potential in microorganisms, histidine auxotrophic strains of Salmonella typhimurium, TA98, TA100, TA1535, and TA1537, and tryptophan auxotrophic Escherichia coli strain, WP2uvrA, were used. The bacterial reverse mutation (Ames) test was performed using five concentrations of the test substances (0, 61.7, 185, 556, 1,670, $5,000{\mu}g/plate$). The evaluation did not reveal repetitive increase of colony generating values and positive criteria for reverse mutagenicity for any tested concentration in the five strains regardless of the presence of metabolic activation system, and no dose-dependency. In conclusion, the safety of 23%-GNANA test substance was verified by the bacterial reverse mutation test conducted before registration of 23%-GNANA as a food additive.

Field Study of Emission Characteristics of Ammonia and Hydrogen Sulfide by Pig Building Types (돈사 작업장 유형에 따른 암모니아와 황화수소의 실내농도 및 발생량에 관한 현장 조사)

  • Kim, Ki Youn;Park, Jae Beom;Kim, Chi-Nyon;Lee, Kyung Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.36-43
    • /
    • 2006
  • The principal aim of this field study was to determine the concentrations and emissions of gaseous contaminants such as ammonia and hydrogen sulfide in the different types of pig buildings in Korea and allow objective comparison between Korea and the other countries in terms of pig housing types. This field study was performed from May to June and from September to October in 2002. Pig buildings investigated in this research were selected in terms of three criteria; manure removal system, ventilation mode and growth stage of pig. Measurements of concentration and emission of ammonia and hydrogen sulfide in the pig buildings were done in 5 housing types and the visited farms were 15 sites per each housing type. Concentrations of ammonia and hydrogen sulfide were measured at three locations of the central alley in the pig building and emission rates of them were estimated by multiplying the average concentration($mg/m^3$) measured near the air outlet by the mean ventilation rate($m^3/h$) and expressed either per pig of liveweight 75kg(mg/h/pig) or per area($mg/h/m^2$). Concentrations of ammonia and hydrogen sulfide in the pig buildings were averaged to 7.5 ppm and 286.5 ppb and ranged from 0.8 to 21.4 ppm and from 45.8 to 1,235 ppb, respectively. The highest concentrations of ammonia and hydrogen sulfide were found in the mechanically ventilated buildings with slats; 12.1 ppm and 612.8 ppb, while the lowest concentrations of ammonia and hydrogen sulfide were found in the pig buildings with deep-litter bed system(2.2 ppm) and the naturally ventilated pig buildings with manure removal system by scraper(115.2 ppb), respectively(p<0.05). All the pig buildings were investigated not to exceed the threshold limit values(TLVs) of ammonia(25 ppm) and hydrogen sulfide(10 ppm). The mean emissions of ammonia and hydrogen sulfide per pig(75kg in terms of liveweight) and area($m^2$) from pig buildings were 250.2 mg/h/pig and 37.8 mg/h/pig and $336.3mg/h/m^2$ and $50.9mg/h/m^2$, respectively. The pig buildings with deep-litter bed system showed the lowest emissions of ammonia and hydrogen sulfide(p<0.05). However, the emissions of ammonia and hydrogen sulfide from the other pig buildings were not significantly different(p>0.05). Concentrations and emissions of ammonia and hydrogen sulfide were relatively higher in the pig buildings managed with deep-pit manure system with slats and mechanical ventilation mode than the different pig housing types. In order to prevent pig farm workers from adverse health effect caused by exposure to ammonia and hydrogen sulfide in pig buildings, they should wear the respirators during shift and be educated sustainably for the guideline related to occupational safety.

Changes in Renal Function by Nebulized Colistimethate Treatment (Colistimethate 분무요법 시행 환자에서 투여 전후 신기능의 변화)

  • Ahn, Hye Jin;Jung, Yoo Jin;Kim, Jae Song;Kim, Soo Hyun;Son, Eun Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.2
    • /
    • pp.92-98
    • /
    • 2017
  • Background: Nebulized colistimethate is increasingly used, because there are problems such as renal dysfunction and low distribution within the lungs when colistimethate is administered intravenously. This study was designed to compare and analyze the changes in renal function by of nebulized colistimethate treatment for its safe administration. Methods: This study retrospectively reviewed the electronic medical records of adult patients above 19 years old, receiving only the nebulized colistimethate at least 4 days in Yonsei university health system from Nov 2014 to Aug 2015. Acute kidney injury (AKI) was determined by using the RIFLE criteria (Risk, Injury, Failure, Loss and End-stage renal disease) according to serum creatinine (SCr) levels before and after use of nebulized colistimethate. Results: 48 patients were included our study and their SCr increased significantly after nebulized colistimethate treatment ($SCr_0$ vs. $SCr_1$; $0.85{\pm}0.80$ vs. $1.00{\pm}0.82mg/dL$, n=48, p<0.001), but the changes were in normal range according to the standards at Yonsei university health $system^a$. Among 48 patients, 38 patients were in the non-AKI group (79.2%), and 10 patients developed AKI (20.8%). Within the AKI group, 2 patients were in the Injury group (20%) and the other 8 in the Risk group (80%). Conclusion: There was no significant difference in age, dosage and duration of treatment between AKI group and non-AKI group (p>0.05). The study has a significance in that it reviewed the safety of nebulized colistimethate only treatment to national patients, analyzing its nephrotoxicity. It has confirmed that nebulized colistimethate is a safer method than intravenous injection, and requires to establish a guideline for the use of nebulized colistimethate in further studies with broader patient groups. $^a$ : SCr Male 0.68-1.19 mg/dL, Female 0.49-0.91 mg/dL.