• Title/Summary/Keyword: Safety Evaluation

Search Result 7,745, Processing Time 0.037 seconds

Quantitative Analysis and Enantiomeric Separation of Ephedra Alkaloids in Ma Huang Related Products by HPLC-DAD and UPLC-MS/MS

  • Kyoung-Moon Han;Jinwoo Hwang;Sun Hee Lee;Boreum Park;Hyungil Kim;Sun Young Baek
    • Natural Product Sciences
    • /
    • v.28 no.4
    • /
    • pp.168-180
    • /
    • 2022
  • Ephedra is a genus of the Ephedraceae family and is found in temperate regions, such as Central Asia and Europe. Among the various ephedra species, Ma Huang (Ephedra herb) is derived from the aerial parts of Ephedra sinica S tapf, Ephedra equisetina Bunge, and Ephedra intermedia Schrenk & C.A. Mey. Ma Huang contains various ephedra alkaloids, including (-)-ephedrine, (+)-pseudoephedrine, (-)-norephedrine, (+)-norpseudoephedrine, (-)-methylephedrine, and (+)-methylpseudoephedrine, which are found naturally as single enantiomers, although they can be prepared as racemates. Although the use of Ma Huang in foods is prohibited in Korea, products containing Ma Huang can be imported, and so it is necessary to develop a suitable analytical technique for the detection of Ma Huang in foods. Herein, we report the development of analytical methods for the detection of ephedra alkaloids in products containing Ma Huang. Following sample purification by solid phase extraction, quantitative analysis was performed using ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS). Additionally, the enantiomers were successfully separated using HPLC-DAD. We successfully analyzed various food samples, where the ephedra alkaloids were qualitatively and quantitatively determined, and the enantiomers were separated. It is expected that these methods may contribute toward preventing the distribution of illegal products containing Ma Huang.

Multiclass Method for the Determination of Anthelmintic and Antiprotozoal Drugs in Livestock Products by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hyunjin Park;Eunjung Kim;Tae Ho Lee;Sihyun Park;Jang-Duck Choi;Guiim Moon
    • Food Science of Animal Resources
    • /
    • v.43 no.5
    • /
    • pp.914-937
    • /
    • 2023
  • The objective of this study was to establish a multi-residue quantitative method for the analysis of anthelmintic and antiprotozoal drugs in various livestock products (beef, pork, and chicken) using ultra-high-performance liquid chromatography-tandem mass spectrometry. Each compound performed validation at three different levels i.e., 0.5, 1, and 2× the maximum residue limit according to the CODEX guidelines (CAC/GL 71-2009). This study was conducted according to the modified quick, easy, cheap, effective, rugged, and safe procedure. The matrix-matched calibrations gave correlation coefficients >0.98, and the obtained recoveries were in the range of 60.2%-119.9%, with coefficients of variation ≤32.0%. Furthermore, the detection and quantification limits of the method were in the ranges of 0.03-3.2 and 0.1-9.7 ㎍/kg, respectively. Moreover, a survey of residual anthelmintic and antiprotozoal drugs was also carried out in 30 samples of beef, pork, and chicken collected in Korea. Toltrazuril sulfone was detected in all three samples. Thus, our results indicated that the developed method is suitable for determining the anthelmintic and antiprotozoal drug contents in livestock products.

Discrimination of biological and artificial nicotine in e-liquid

  • Hyoung-Joon Park;Heesung Moon;Min Kyoung Lee;Min Soo Kim;Seok Heo;Chang-Yong Yoon;Sunyoung Baek
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.22-31
    • /
    • 2023
  • As the use of e-liquid cigarettes is rapidly increasing worldwide, it multiplies the potential risk undisclosed to the health of non- and smokers. To reduce the hazard, each country has its own set of regulations for controlling e-liquids. In Korea, the narrow definition of tobacco makes it difficult and have been steadily occurring tax evasion exploiting the difference in natural and artificial nicotine. Therefore, it is very important to distinguish source of nicotine for their regulation. To find biochemical discriminant markers, this study established analysis methods based on high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) and high-performance liquid chromatography coupled with triple Quadrupole mass spectrometry (HPLC-MS/MS) for nicotine enantiomers and tobacco alkaloids targeted using the difference in pathways of nicotine biosynthesis and chemical synthesis. The method was validated by experimenting linearity (R2 > 0.999), recovery (80.99-108.41 %), accuracy (94.11-109.73 %) and precision (0.04-8.27 %). Then, the results for discrimination of the nicotine obtained from analysis of 65 commercial e-liquid products available in Korean market was evaluated. The method successfully applied to the e-liquids and one sample labelled 'synthetic nicotine' for tax exemption was found to contain a natural nicotine product. This method can be used to determine whether an e-liquid product uses natural or artificial nicotine and monitor non-taxable e-liquid products. The method is more scientific than the existing one, which relies only on field evidence.

A Study on Evaluation Method of the HDA Test in Domestic Road Environment (국내도로 환경에서의 HDA 시험평가 방법에 관한 연구)

  • Bae, Geon Hwan;Kim, Bong Ju;Lee, Seon Bong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.39-49
    • /
    • 2019
  • Autonomous vehicle is a car which drives itself without any human interaction. SAE provides technical definitions for autonomous and international standards for test evaluation. Accordingly, automobile industry is actively researching development and evaluation of various ADAS (Advanced Driver Assistance Systems), : representative technology of autonomous technology. Recently, ADAS is in the commercialization level such as ACC, LKAS, AEB, and HDA etc. And it also has issues about safety evaluation. The purpose of HDA in ADAS is reduced the driving load on highway. It has a function which can maintain lane keeping and control distance from forward vehicle. This function is evaluated to be useful for accident prevention. Therefore, this paper proposes the safety evaluation scenario of HDA, considering the domestic highway design criteria and the situation that may arise on the actual highway. We compared and analyzed the data acquired through simulation and actual vehicle test. And verified the reliability of the proposed safety evaluation scenario. The verified result is expected safety evaluation of HDA is possible even under the bad condition, which cannot be tested.

Evaluation of Navigational Safety Using the Integrated Seakeeping Performance Index under Loading Conditions of a Ship (선박의 적화 상태별 종합내항성능지표에 의한 항해 안전성 평가)

  • 김순갑;김정만;공길영
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.2
    • /
    • pp.43-52
    • /
    • 1998
  • Generally, the navigational safety of a ship under various loading conditions is evaluated by a loading manual. However, the loading manual handles only statical factors such as weight and buoyancy of ship without including any wave conditions. Practically ship's safety is much concerned with the occurrences on the rough sea as propeller racing, rolling, deck wetness, vertical acceleration, lateral acceleration, slamming and so on. The purpose of this paper is to present a synthetic and practical evaluation method of navigational safety using the integrated seakeeping performance index(ISPI) under loading conditions of ship in seaways. The method is calculated by means of the ISPI by measuring only vertical acceleration. Judgement of dangerousness is carried out for four lading conditions : homogeneous full loaded, half loaded, heavy ballast loaded, and normal ballast loaded conditions. In developing the practical evaluation system of navigational safety, it is useful to solve the difficulties in measuring factors by sensors. And by applying the evaluation diagrames, navigators are able to avoid dangerousness by keeping away of the danger encountering angle of wave direction which the diagram shows.

  • PDF

A Case Study on the Structural Safety Evaluation of a building with Adversiting Pillar Tower (광고탑이 설치된 건축 구조물의 구조안전성 평가에 관한 사례 연구)

  • 은충기;채원규;손영현
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.147-152
    • /
    • 1998
  • In this thesis, the structural safety evaluation of a building with adversiting pillar tower were studied. From the structural analysis results of a building with adversiting pillar tower, the bending stress, the shearing stress and the axial stress were calculated, and these member forces were applied to the structural safety evaluation of a building with adversiting pillar tower.

  • PDF

A study on Design of Plant Safety Evaluation for Increasing Productivity (생산성향상을 위한 설비안전평가 시스템 설계)

  • Yang, Gwang-Mo;Seo, Jang-Hun;Jo, Yong-Uk;Lee, Gong-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.339-344
    • /
    • 2008
  • This study's purpose centers plant management activities that is management system for total plant efficiency's maximization, plant evaluation system that production and safety management activities factor that is enforcing in manufacturing industry can develop evaluation model that can evaluate quantitative activities in process that maximize productivity and safety efficiency wishes to do design.

  • PDF

Measurement of Human Cytochrome P450 Enzyme Induction Based on Mesalazine and Mosapride Citrate Treatments Using a Luminescent Assay

  • Kim, Young-Hoon;Bae, Young-Ji;Kim, Hyung Soo;Cha, Hey-Jin;Yun, Jae-Suk;Shin, Ji-Soon;Seong, Won-Keun;Lee, Yong-Moon;Han, Kyoung-Moon
    • Biomolecules & Therapeutics
    • /
    • v.23 no.5
    • /
    • pp.486-492
    • /
    • 2015
  • Drug metabolism mostly occurs in the liver. Cytochrome P450 (CYP) is a drug-metabolizing enzyme that is responsible for many important drug metabolism reactions. Recently, the US FDA and EU EMA have suggested that CYP enzyme induction can be measured by both enzymatic activity and mRNA expression. However, these experiments are time-consuming and their interassay variability can lead to misinterpretations of the results. To resolve these problems and establish a more powerful method to measure CYP induction, we determined CYP induction by using luminescent assay. Luminescent CYP assays link CYP enzyme activity to firefly luciferase luminescence technology. In this study, we measured the induction of CYP isozymes (1A2, 2B6, 2C9, and 3A4) in cryopreserved human hepatocytes (HMC424, 478, and 493) using a luminometer. We then examined the potential induction abilities (unknown so far) of mesalazine, a drug for colitis, and mosapride citrate, which is used as an antispasmodic drug. The results showed that mesalazine promotes CYP2B6 and 3A4 activities, while mosapride citrate promotes CYP1A2, 2B6, and 3A4 activities. Luminescent CYP assays offer rapid and safe advantages over LC-MS/MS and qRT-PCR methods. Furthermore, luminescent CYP assays decrease the interference between the optical properties of the test compound and the CYP substrates. Therefore, luminescent CYP assays are less labor intensive, rapid, and can be used as robust tools for high-throughput CYP screening during early drug discovery.

Estrogenic Activity of Persistent Organic Pollutants and Parabens Based on the Stably Transfected Human Estrogen Receptor-α Transcriptional Activation Assay (OECD TG 455)

  • Kim, Tae-Sung;Kim, Chang-Yeong;Lee, Hae-Kyung;Kang, Il-Hyun;Kim, Mi-Gyeong;Jung, Ki-Kyung;Kwon, Yong-Kwan;Nam, Hye-Seon;Hong, Soon-Keun;Kim, Hyung-Sik;Yoon, Hae-Jung;Rhee, Gyu-Seek
    • Toxicological Research
    • /
    • v.27 no.3
    • /
    • pp.181-184
    • /
    • 2011
  • Screening of estrogenic activity on dichloro diphenyl trichloroethane (DDT), dichloro diphenyl dichloro ethylene (DDE), dieldrin, heptachlor, aldrin, chlordane, lindane, polybrominated diphenyl ethers (PBDE) and parabens was compared using Organization for Economic Cooperation and Development (OECD) test guideline 455 (TG455). The estrogenic activity of DDT was 58,000-fold ($PC_{50}$, $1.67{\times}10^{-6}$ M) less than $17{\beta}$-estradiol($E_2$) ($PC_{50}$, $2.88{\times}10^{-11}$ M) but DDE, dieldrin, heptachlor, aldrin, chlordane, lindane and PBDE did not show any estrogenic activity in this assay system. In the case of paraben compounds, the rank of relative transcriptional activation (logRTA) was butyl paraben -1.63752 ($PC_{50}$, $1.25{\times}10^{-7}$ M) > isobutyl paraben -2.34008 ($PC_{50}$, $6.3{\times}10^{-7}$ M) > ethyl paraben -2.64016 ($PC_{50}$, $1.26{\times}10^{-6}$ M) > isopropyl paraben -2.73993 ($PC_{50}$, $1.58{\times}10^{-6}$ M) > propyl paraben -2.84164 ($PC_{50}$, $2.0{\times}10^{-6}$ M). Our data suggest that OECD test guideline TG455 may be useful as a screening tool for potential endocrine disruptors.

Effects of Mercuric Chloride on Gene Expression in NRK-52E Cells

  • Ahn, Joon-Ik;Baik, Si-Yeon;Ko, Moon-Jeong;Shin, Hee-Jung;Chung, Hye-Joo;Jeong, Ho-Sang
    • Genomics & Informatics
    • /
    • v.8 no.1
    • /
    • pp.50-57
    • /
    • 2010
  • Mercuric chloride, a model nephrotoxicant was used to elucidate time- and dose- dependent global gene expression changes associated with proximal tubular toxicity. Rat kidney cell lines NRK-52E cells were exposed for 2, 6 and 12 hours and with 3 different doses of mercuric chloride. Cell viability assay showed that mercuric chloride had toxic effects on NRK-52E cells causing 20% cell death (IC20) at $40{\mu}M$ concentration. We set this IC20 as high dose concentration and 1/5 and 1/25 concentration of LC20 were used as mid and low concentration, respectively. Analyses of microarray data revealed that 738 genes were differentially expressed (more than two-fold change and p<0.05) by low concentration of mercuric chloride at least one time point in NRK-52E cells. 317 and 2,499 genes were differentially expressed at mid and high concentration of mercuric chloride, respectively. These deregulated genes showed a primary involvement with protein trafficking (CAV2, CANX, CORO1B), detoxification (GSTs) and immunity and defense (HMOX1, NQO1). Several of these genes were previously reported to be up-regulated in proximal tubule cells treated with nephrotoxicants and might be aid in promoting the predictive biomarkers for nephrotoxicity.