• Title/Summary/Keyword: Safety Device

Search Result 1,780, Processing Time 0.03 seconds

Wind Pressure Analysis of Movable Shading Using CFD (CFD 해석을 이용한 가변 차양 장치의 풍압력 분석)

  • Kim, Gee-Chul;Lee, Joon-Ho;Baik, Yong-Kyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.83-90
    • /
    • 2019
  • Most of the variable shading devices are installed outdoors, so they are greatly affected by structural safety due to external climate change, wind, rain, and snow. Especially, due to strong wind such as typhoons, safety problems may occur due to the dropout of the device. Therefore, it is necessary to secure the structural safety against the wind. Therefore, it is necessary to analyze the structural behavior of the windshield to evaluate the structural safety of the variable sunshade device. In this study, we analyze the wind pressure applied to the shading material according to the change of the length of the variable shading device, and apply it to the calculation of the wind load for the structural design of the variable shading device. The CFD (Computational Fluid Dynamic) analysis of the structure of the sample was used to analyze wind pressure magnitude and distribution. In order to estimate the wind pressure, the maximum wind loads of the static and negative pressures acting on the structure were analyzed from numerical simulation results.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Parametric Study of Asymmetric Base-Isolation Coupling Control System for Vibration Control of Adjacent Twin Buildings (쌍둥이 인접구조물의 진동 제어를 위한 비대칭 지진격리 연결 제어시스템의 매개변수연구)

  • Kim, David;Park, Wonsuk;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.45-51
    • /
    • 2022
  • This paper focuses on a recently proposed asymmetric base-isolation coupling control system (ABiCS) for the vibration control of adjacent twin buildings. The ABiCS consists of inter-story diagonal dampers, a connecting damper between the two buildings, and a seismic isolation device at the base floor of one building. To investigate the control characteristics of ABiCS, a parametric study was performed by numerically simulating the 20-story twin buildings. In the parametric study, the control capacities of the inter-story diagonal dampers, connecting damper, and seismic isolation device were considered as varying parameters. The parametric study results indicate that the connecting damper between the two buildings reduces the responses of both buildings only at optimal or near-optimal capacity. In addition, adjusting the stiffness of the base isolation is found to be the most effective method for improving seismic performance and achieving cost-effectiveness. Accordingly, we presented a scenario-based performance improvement approach in which reducing the stiffness of the base isolation device could be an effective technique to improve the seismic performance of both buildings. However, note that checking the maximum allowable displacement of the base isolation device is essential.

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

Computational Study for the Performance of Fludic Device during LBLOCA using TRAC-M (최적계산코드를 이용한 대형 냉각재상실사고시 유량조절기 성능평가에 관한 연구)

  • Chon Woochong;Lee Jae Hoon;Lee Sang Jong
    • Journal of Energy Engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2005
  • The APR1400 is an Advanced Pressurized Water Reactor with 3983 MWt power, 2×4 loops, and direct vessel injection system. The Fluidic Device (FD) is adopted to regulate the safety injection flow rate in a Safety Injection Tank (SIT) of APR1400. The performance of a newly designed fluidic Device is evaluated by analyzing a Large Break Loss-of-Coolant Accident (LBLOCA) using TRAC-M/F90, version 3.782. The analysis results show that the TRAC-M code reasonably predicts the important phenomena of blowdown, refill and reflood phases of LBLOCA. The sensitivity studies about gas/water volume changes in a SIT and K factor changes in a SI system were also done to understand the important phenomena with a Fluidic Device in APR1400.

The basic study on the design of the Light Collision Safety Device (경충돌안전장치 설계를 위한 기초연구)

  • Choi, Won-Mog;Jung, Hyun-Sung;Yu, Won-Hui;Ku, Jung-Seo;Kwon, Tae-Su
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.238-244
    • /
    • 2006
  • The Light Collision Safety Device is used to protect the important part of trains and passengers at the low velocity accidents. The Light Collision Safety Device comprises mainly tension bolts, shear bolts and an energy absorber. The work mechanism of this device is that first, the tension bolts break at designed collapse load and second, the energy absorber absorb rest collision energy. In this paper, the tension bolt characteristics were validated by the simple tension test using the FEM(Finite Element Method) and the characteristic of the two types of energy absorber were compared by using the load-displacement curves and absorbed energy. Last, in order to determine integrated load-displacement curve of tension bolts and the energy absorber, the unified analysis was conducted by using the FEM.

  • PDF

Simplified Parametric Study on M125 Booster Mechanism and its Application for Determining the Characteristic Constant of Arming Distance (M125 부스터 메카니즘의 해석 및 응용)

  • Rim, One kwon;Kim, Sung shik;Bang, Jae won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.409-414
    • /
    • 2015
  • M125 booster is one of the reliable S&A device(safety and arming device) to determine the arming distance of fuze for gun ammunitions from 90 mm to 8 inch in diameter. And it is also well known that the arming distance of M125 booster is determined by the multiplication value of the gun tube property(traveled distance per turn of projectile) and the S&A device property(number of turns to arm), not by the projectile muzzle velocity. We have tried and succeeded in executing a proper analysis on M125 booster to figure out its characteristic constant of arming distance by considering only the gun tube properties and the S&A device properties. More detailed arming distance will be analyzed in the future by considering dynamic characteristics on all elements in the S&A device with vector analysis.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices : Bone Absorptiometric X-ray System (엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Kim, Eun-Rim;Lee, Jun-ho;Lee, Chang-Hyung;Park, Chang Won
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.263-271
    • /
    • 2016
  • The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

A Study on OLED display device's line defect test methode (OLED display device의 Line Defect 시험법에 관한 연구)

  • Choi, Young-Tae;Choi, Jai-Rip
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

A research for improvement methods in the aspect of safety engineering through risk analysis of facilities for multiple use - Focused on escalator and passenger conveyors - (다중이용시설물 위험분석을 통한 안전공학적 개선 방안에 관한 연구 (에스컬레이터 및 수평보행기를 중심으로))

  • Kwon, Sun-Geol;Kim, Jin-Soo;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.31-40
    • /
    • 2013
  • For the matter of elevator, one of the multi-use facilities for unspecified public, the JIS has re-established and reformed to apply to the environment in South Korea for the past 20 years. In the aspect of safety assurance, it was inevitable to suggest improved measures. The government, Ministry of Public Administration and Security has secured the safety by enhancing the safety management functions in the elevator inspection standards and expanding its safety device measures. Further, the international inspection standard has been introduced, which is about unifying inspection standard system into the international standard code. In March 14th 2012, the international standard (EN) has been amended and fully announced. Escalator and passenger conveyor among lift devices have several common danger factor that cause safety accident. First, the accident caused by decreased braking power of brake. Second, the accident caused by the rate difference between handrail and tread-board. Third, the accident caused by defects of contraflow preventing device or carelessness inspection. Fourth, the accident caused by wet tread-board or wet floor of platform which makes passenger slip and fall. As the improvements to prevent and reduce these negligent accidents, the inspection list to check and methods should be subdivided and applied for each accident likelihood cause for safety management enhancement and safety assurance of existing escalator and passenger conveyors. The escalators and passenger conveyors without safety devices in existence should be obliged to modify the part of the system or install additional safety device. With making these measures obligations, it requires to improve the system to be suitable for the international inspection standard and to have measures to prevent safety accidents. It also needs to arrange improvements for skid accident of tread-board by the external environment factors such as snow and rain.