Abstract
The APR1400 is an Advanced Pressurized Water Reactor with 3983 MWt power, 2×4 loops, and direct vessel injection system. The Fluidic Device (FD) is adopted to regulate the safety injection flow rate in a Safety Injection Tank (SIT) of APR1400. The performance of a newly designed fluidic Device is evaluated by analyzing a Large Break Loss-of-Coolant Accident (LBLOCA) using TRAC-M/F90, version 3.782. The analysis results show that the TRAC-M code reasonably predicts the important phenomena of blowdown, refill and reflood phases of LBLOCA. The sensitivity studies about gas/water volume changes in a SIT and K factor changes in a SI system were also done to understand the important phenomena with a Fluidic Device in APR1400.
Keywords
TRAC-M; APR1400; fluidic device; LOCA;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Steinke, R.G. et al. 'TRAC-M/FORTRAN 90 (Version 3.0) User's Mannual', Los Alamos National Laboratory, 2001, NUREG/CR-6722
2 Song, J.H.; Kim, T.Y.; Choi, H.R.; Choi, C.J.; Seo, J.T. 'Effects on LOCA Mass and Energy Release of the SIT Fluidic Device for SKN 3&4', NURETH-10, Seoul, Korea, 2003
3 Korea Atomic Energy Research Institute. 'Scaling Analysis of the Thermal Hydraulic Test Facility for the Large Break LOCA of KNGR', KAERI/TR-18781/2001, 2001
4 Lee, S.w.; Oh, S.J. 'Investigation of APR 1400 Large Break Loca Scenario using Relap5/Mod3', NURETH-10, Seoul, Korea, 2003
5 Korea Atomic Energy Research Institute. 'Fluidic Device Performance Test using the VAPER Test Facility', VAPER-QLR-005, 2003
6 과학기술부. '가압경수로의 비상노심냉각계통의 성능에 관한 기준', 과학기술부고시, 2001, 제2001-39호