• Title/Summary/Keyword: Safety Circuit Design

Search Result 136, Processing Time 0.029 seconds

An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material (방전전극 재질과 최소점화에너지에 관한 실험 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants (원전 노출 화재시 케이블 기능상실 온도에 관한 연구)

  • Kim, Doo-Hyun;Lim, Hyuk-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test (삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션)

  • Lee, Eung-Ro;Lee, Seung-Je;Lee, Chan-Joo;Ko, Tae-Kuk;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

The Selection of the Condenser Positions for the Improvement Power Factor of the High Voltage Induction Motors (고압유도전동기의 역률개선을 위한 콘덴서 위치 선정 방안)

  • Lee, Eun-Chun;Jeon, Il-Bang;Kim, Chang-Bum;Choe, Yeong-Gyu;Shin, Kang-Uk;Hong, Sung-Taek;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1068-1070
    • /
    • 2005
  • This study sorted high voltage motors by the voltage and the capacity and analyzed the property of motor-start. So we found out some problems of the starting circuit from several sites, and made the answers of the problems. If these results of our study are utilized in new WTPs, the safety of the starting circuit will be improved and the life of electric power system will be longer. We recommend this study as a reference when our company founds the standard of electric facility design.

  • PDF

A Study on the Design of EL Inverter using FET (FET를 이용한 EL용 인버터 설계에 관한 연구)

  • 이기제;윤석암;윤형상;조경재;최장균;임중열;차인수;이경섭
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.456-459
    • /
    • 1999
  • This paper presents about EL(electroluminescent) driver with inverter. Inverter is composited two FET to increase safety output voltage. As result this study, the optimum operating condition of inverter is that the gate bias frequency of FET equal two resonant frequency of circuit. It shows to ideal sinusoidal output wave. Finally, EL sampler(15cm$\times$15cm) gain 2.6 [lux] with 1cm.

  • PDF

Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System (대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계)

  • Kim, Eun Min;Kang, Chang yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.

Design of Hydraulic Power Lifter for the Elder and the Handicapped (노약자용 휠체어 리프트 유압시스템 설계)

  • Lee, Cheol Soo;Lim, Goo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.3
    • /
    • pp.68-73
    • /
    • 2002
  • This study has been advanced to the design method for embodying the hydraulic circuit and control device in considering the safety for the development of wheelchair lift, using in the public transportation bus. Recently, mobility and accessibility occurs for the elder and the handicapped in the aging problem, In this paper, we design the hydraulic power system to operate lifter loading one wheelchair handicapped person and one's supporter to get in the bus. We develop the lifter safely. We check the trajectories of lifter inside frame box to protect its corrosion and the stress at the joints of mechanical structure. Those can be helped to keep the safety and accuracy of the multiple dynamic systems for precision quality assurance in mass production.

  • PDF

Design of Hydraulic Power Lifter for the Elder and the Handicapped (노약자용 휠체어 리프트 유압시스템 설계)

  • Lee, Soo-Cheol;Lim, Goo
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.1-6
    • /
    • 2002
  • This study has been advanced to the design method for embodying the hydraulic circuit and control device in considering the safety for the development of wheelchair lift, using in the public transportation bus. Recently, mobility and accessibility occurs for the elder and the handicapped in the aging problem, In this paper, we design the hydraulic power system to operate lifter loading one wheelchair handicapped person and one's supporter to get in the bus. We develop the lifter safely. We check the trajectories of lifter inside frame box to protect its corrosion and the stress at the joints of mechanical structure. Those can be helped to keep the safety and accuracy of the multiple dynamic systems for precision quality assurance in mass production.

  • PDF

Study on Safety Management Plan through Chemical Accident Investigation in PCB Manufacturing Facility Etching Process (PCB 제조시설 에칭공정 화학사고 조사를 통한 안전관리 방안 연구)

  • Park, Choon-Hwa;Kim, Hyun-Sub;Jeon, Byeong-Han;Kim, Duk-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.132-137
    • /
    • 2018
  • Although the number of chemical accidents has been declining since the Chemical Control Act of 2015, there have been repeated occurrences of similar types of accidents at printed circuit board (PCB) manufacturing facilities. These accidents were caused by the overflow of hydrochloric acid and hydrogen peroxide, which are toxic chemicals used in the printed circuit board manufacturing process. An analysis of the $Cl^-$ content to identify the cause of the accident showed that in the mixed route of hydrochloric acid and hydrogen peroxide, which are accidental substances, the $Cl^-$ concentration was 66.85 ppm in the hydrogen peroxide sample. Through reaction experiments, it was confirmed that the deformation of a PVC storage tank and generation of chlorine gas, which is a toxic gas, occurred due to reaction heat occurring up to $50.5^{\circ}C$. This paper proposes a facility safety management plan, including overcharge, overflow prevention, leak detection device, and separation tank design for mixing prevention in printed circuit board manufacturing facility etch process. To prevent the recurrence of accidents of the same type, the necessity of a periodic facility safety inspection and strengthening of the safety education of workers was discussed.

Flight Safety Improvement on Surion through Circuit Design and Software Reformation of Data Acquisition Unit (수리온 데이터획득/처리장치 동작회로 및 소프트웨어 개선을 통한 비행안전성 향상)

  • Jun, Byung-kyu;Jeong, Sang-gyu;Kim, Young-mok;Chang, In-ki
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.370-378
    • /
    • 2015
  • The data acquisition unit, signal acquiring and processing equipment, processes and provides major data of an aircraft such as engine system, power train system, hydraulic system, etc. However, it had lots of failure related to the system during production test flight, and it is necessary to fix them perfectly as soon as possible because of the significance of the equipment. In this paper, it contains failure classification and analysis for each defect element to improve whole software as well as electrical circuit. Particularly, utilizing Fault Injection Method based interworking test, more efficient improvement activity was performed for not only equipment level but also aircraft level, and as a result, it is achieved that considerable betterment of Surion quality and flight safety.