• Title/Summary/Keyword: Safe discharge

Search Result 148, Processing Time 0.028 seconds

A Novel Electrostatic Discharge (ESD) Protection Device by Current Feedback Using $0.18\;{\mu}m$ Process ($0.18\;{\mu}m$ 공정에서 전류 피드백을 이용한 새로운 구조의 정전기 보호 소자에 관한 연구)

  • Bae, Young-Seok;Lee, Jae-In;Jung, Eun-Sik;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.3-4
    • /
    • 2009
  • As device process technology advances, effective channel length, the thickness of gate oxide, and supply voltage decreases. This paper describes a novel electrostatic discharge (ESD) protection device which has current feedback for high ESD immunity. A conventional Gate-Grounded NMOS (GGNMOS) transistor has only one ESD current path, which makes, the core circuit be in the safe region, so an GGNMOS transistor has low current immunity compared with our device which has current feedback path. To simulate our device, we use conventional $0.18\;{\mu}m$ technology parameters with a gate oxide thickness of $43\;{\AA}$ and power supply voltage of 1.8 V. Our simulation results indicate that the area of our ESD protection, device can be smaller than a GGNMOS transistor, and ESD immunity is better than a GGNMOS transistor.

  • PDF

Acute Viral Hepatitis A with Cholestatic Hepatitis Treated with Traditional Korean Medicine : A Case Report

  • Kim, Jun-Young;Joung, Jin-Yong;Kang, Ji-Young;Son, Chang-Gue;Cho, Jung-Hyo
    • The Journal of Korean Medicine
    • /
    • v.36 no.4
    • /
    • pp.114-121
    • /
    • 2015
  • More and more patients suffering from hepatitis A, the number of patients representing symptoms that are uncharacteristic to hepatitis A is also increasing. There are occasions of serious complications among adult hepatitis A patients that can cause fulminant hepatitis or cirrhosis which can be fatal. A 43-year-old male was diagnosed as acute hepatitis A and was treated at a Western hospital over the course of three months, which included two months of hospitalization. However, his symptoms did not improve, so he was admitted to Oriental hospital. We prescribed Chunggan extract (CGX) four times a day. Acupuncture was performed twice a day. From the twenty-fourth day of admission, the total bilirubin fell under 10 mg/dL for the first time and next day he was discharged. Following his discharge, he consistently took CGX three times a day. 21 days after discharge all of his symptoms disappeared. This study demonstrated that traditional Korean medicine (TKM) for acute viral hepatitis with cholestatic hepatitis might be effective and safe with no adverse effects.

Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed (유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구)

  • Moon, Kyoon-Tae;Chung, Jae-Hee;Choi, Kwang-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.

An Experimental Study of the Spray Characteristics for an Oxidizer-rich Preburner Injector (산화제 과잉 예연소기 인젝터의 분무 특성에 관한 연구)

  • So, Y.S.;Yang, J.H.;Han, Y.M.;Choi, S.M.
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The spray characteristics of the oxidizer-rich preburner are investigated. This system is generally operated at an oxidizerfuel mixture ratio of 50. The spray quality and mixing performance are very important for safe combustion. To know the spray characteristics of the oxidizer-rich preburner, we have designed various swirl injectors and measured droplet velocity and size by the PDPA system. The flow discharge coefficient of the fuel orifice is $0.12{\sim}0.21$, oxidizer orifice discharge coefficient is $0.16{\sim}0.28$. From the spray visualization, fuel nozzle spray angle is $15^{\circ}{\sim}25^{\circ}$, oxidizer nozzle spray angle is $65^{\circ}{\sim}85^{\circ}$ and combined spray angle is reduced $2^{\circ}{\sim}5^{\circ}$ compared to the oxidizer nozzle only case. From the PDPA measurement, droplet SMD is $175\;{\mu}m$ at 50 mm and $190\;{\mu}m$ at 100 mm of variant 1 combined case. The number concentration measurement revealed the reason of the droplet diameter increasement with distance. That is due to drop coalescence results from collision of drops which is occurred in dense sprays at a long distance from nozzle orifice exit.

  • PDF

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

Fault Detection Algorithm of Charge-discharge System of Hybrid Electric Vehicle Using SVDD (SVDD기법을 이용한 하이브리드 전기자동차 충-방전시스템의 고장검출 알고리듬)

  • Na, Sang-Gun;Yang, In-Beom;Heo, Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.11
    • /
    • pp.997-1004
    • /
    • 2011
  • A fault detection algorithm of a charge and discharge system to ensure the safe use of hybrid electric vehicle is proposed in this paper. This algorithm can be used as a complementary way to existing fault detection technique for a charge and discharge system. The proposed algorithm uses a SVDD technique, which additionally utilizes two methods for learning a large amount of data; one is to incrementally learn a large amount of data, the other one is to remove the data that does not affect the next learning using a new data reduction technique. Removal of data is selected by using lines connecting support vectors. In the proposed method, the data processing speed is drastically improved and the storage space used is remarkably reduced than the conventional methods using the SVDD technique only. A battery data and speed data of a commercial hybrid electrical vehicle are utilized in this study. A fault boundary is produced via SVDD techniques using the input and output in normal operation of the system without using mathematical modeling. A fault detection simulation is performed using both an artificial fault data and the obtained fault boundary via SVDD techniques. In the fault detection simulation, fault detection time via proposed algorithm is compared with that of the peak-peak method. Also the proposed algorithm is revealed to detect fault in the region where conventional peak-peak method is never able to do.

Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator (설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측)

  • Suh, Jeong-Min;Yi, Pyong-In;Jung, Moon-Sub;Park, Jeong-Ho;Lim, Woo-Taik;Park, Chool-Jae;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

Effectiveness and Safety of Korean Medicine for Trigeminal Neuralgia: A Case Report

  • Bae, Ji Min;Kim, Dae Hun;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.34 no.1
    • /
    • pp.59-66
    • /
    • 2017
  • Objectives : This study aims to report the effectiveness and safety of Korean medicine with thread embedding acupuncture in the treatment of trigeminal neuralgia (TN). Methods : A 73-year-old man who had suffered from severe facial pain for one year and who had had a healthy tooth extracted due to the pain is reported. He could not eat or sleep due to the severe pain. Acupuncture, thread embedding acupuncture, cupping, herbal steam, and herbal medicines were used for the treatment. Numeric Rating Scale (NRS) and adverse events were checked daily, and other outcomes (Baseline Evaluation, Visual Analogue Scale [VAS], Short Form Health Survey 36-Bodily Pain [SF-36 BP], and Patient Global Assessment [PGA]) were measured at hospital admission and discharge. During the follow-up examinations, his pain was evaluated roughly, without using any formal measurements, on the basis of a global assessment. Results : All measured parameters, including pain, quality of life, and patient satisfaction were noted to have improved at the time of discharge compared to admission: VAS from 10 to 1.5, NRS from 7-8 to 1-2, and SF-36 BP from 0 to 22.5, and the patient's global assessment was somewhat improved. He did not take any analgesics after discharge and noted only mild adverse events, like pain where the acupuncture and thread embedding acupuncture needles were inserted. His pain relief was maintained for 6 months. Conclusion : Korean medicine with thread embedding acupuncture might be a safe and effective treatment for TN. In the future, larger sample sizes and high quality randomized clinical trials are warranted to confirm its efficacy and safety.