• Title/Summary/Keyword: SWMM-LID

Search Result 73, Processing Time 0.024 seconds

Runoff analysis according to LID facilities in climate change scenario - focusing on Cheonggyecheon basin (기후변화 시나리오에서의 LID 요소기술 적용에 따른 유출량 분석 - 청계천 유역을 대상으로)

  • Yoon, EuiHyeok;Jang, Chang-Lae;Lee, KyungSu
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.583-595
    • /
    • 2020
  • In this study, using the RCP scenario for Hyoja Drainage subbasin of Cheonggyecheon, we analyzed the change with the Historical and Future rainfall calculated from five GCMs models. As a result of analyzing the average rainfall by each GCMs model, the future rainfall increased by 35.30 to 208.65 mm from the historical rainfall. Future rainfall increased 1.73~16.84% than historical rainfall. In addition, the applicability of LID element technologies such as porous pavement, infiltration trench and green roof was analyzed using the SWMM model. And the applied weight and runoff for each LID element technology are analyzed. As a result of the analysis, although there was a difference for each GCMs model, the runoff increased by 2.58 to 28.78%. However, when single porous pavement and Infiltration trench were applied, Future rainfall decreased by 3.48% and 2.74%, 8.04% and 7.16% in INM-CM4 and MRI-CGCM3 models, respectively. Also, when the two types of LID element technologies were combined, the rainfall decreased by 2.74% and 2.89%, 7.16% and 7.31%, respectively. This is less than or similar to the historical rainfall runoff. As a result of applying the LID elemental technology, it was found that applying a green roof area of about 1/3 of the urban area is the most effective to secure the lag time of runoff. Moreover, when applying the LID method to the old downtown area, it is desirable to consider the priority order in the order of economic cost, maintenance, and cityscape.

Analysis of Infiltration Trench Facility for Runoff Reduction Effect (침투트렌치 시설의 유출저감 효과 분석)

  • Yeon, Jong Sang;Jang, Young Su;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5813-5819
    • /
    • 2014
  • LID planning and application has been actively developed to reduce the runoff volume at increased impervious areas due to rapid urbanization. In this study, a performance and applicability evaluation was performed in an infiltration trench using the SWMM model, based on the experimental conditions for infiltration trenches. The infiltration trench application area was applied to 5~15% of the drainage area. The SWMM results of discharge and the BOD reduction efficiency were analyzed at a peak discharge of 45.7~61.9%, total discharge of 47.2~62.3%, and BOD load of 52.3~55.3. The discharge and BOD was estimated to be 12~24% higher and 37~38% smaller than the experimental results. This study can help in the application and performance evaluation of infiltration trenches.

The Urban Water Cycle Planning Elements and Hydrologic Cycle Simulation for Green City (녹색도시 물순환 계획요소 및 수문순환 모의)

  • Lee, Jung-Min;Kim, Jong-Lim
    • Land and Housing Review
    • /
    • v.3 no.3
    • /
    • pp.271-278
    • /
    • 2012
  • The climate change and global warming has been a world-wide issue. Also, the green growth has been a widely adopted strategy for national and regional development. In particular, after the Kyoto Protocol to United Nations Framework Convention on Climate Change was declared, the low carbon society was inevitable phenomenon. The hydrologic cycle in urban catchment has been changed due to the expansion of impervious area by rapid urban development. This paper has examined the Water cycle planning elements for green city in the scale of urban planning as well as site planning including housing site. In this study, the SWMM5-LID (Storm Water Management Model5-LID) model was used to simulate the hydrologic cycle of the test catchment as a typical urban catchment. We performed continuous simulation on urban runoff before and after the development of the test catchment and after the installation of Green city planning Elements.

A Study on the Runoff Reduction According to the Calculation Method of the LID Scale Considering the Land Use Area and the Application of Stormwater Storage Basin (토지이용면적을 고려한 LID 규모 산정 및 우수저류지 적용에 따른 유출저감 연구)

  • Kim, Byung Sung;Kim, Jea Moon;Kim, Seong Su;Shin, Gang Wook;Lee, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.229-235
    • /
    • 2021
  • Globally, due to climate change and urbanization, problems with water cycle destruction in urban areas frequently occur. In order to solve this problem, LID technique is being actively conducted the application in urban and research. In this study, some areas of the new city located in Busan was constructed using a widely used SWMM model to verify the effectiveness of the LID technique. This is to present a plan to maximize the efficiency of urban water cycle of the stormwater management target figure and the LID scale calculation method. In addition, the efficiency of runoff reduction using stormwater storage basin was analyzed in urban development projects. By calculating the scale of customized LID for each sub basin, the amount of runoff and peak runoff after LID application was reduced by 86.8 % and 69.5 %, respectively. Depending on the application of the stormwater storage basin, the reduction effect of peak runoff from 0.5 m3/s to 4.9 m3/s and delay effect of 8 minutes to 10 minutes was shown.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Analysis of Effect on Runoff and Water Quality of LID using Infiltration Facilities (우수 침투 시설을 활용한 친환경 도시 개발지구에서의 유출량 및 비점오염 저감 효과 분석)

  • Hwang, Jin-Yong;Yeon, Kyu-Seok;Kim, Ik-Jae;Kim, Ki-Sung;Choi, Joong-Dae;Jeon, Ji-Hong;Lim, Kyoung-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.105-114
    • /
    • 2009
  • With urbanization in many countries, many pervious areas are being converted into impervious areas. These land use changes cause many negative impacts on runoff and water quality in the areas. Especially runoff volume and peak runoff are increasing with urbanization. In addition to the increased runoff, more pollutant transports to the downstream areas. For these reasons, Low Impact Development (LID) are nowadays being introduced in urban planning. For environment-friendly and economical urban development, the LID Integrated Management Practices (IMPs) are applied in various urban development. However, exact effects on runoff and water quality of various LID IMPs are not assessed with proper LID evaluation technique. Thus, the SWMM (Storm Water Management Model) 5.0 model was slightly modified to simulate the effect of infiltration manhole on runoff and water quality. For comparison of runoff and TSS (Total Suspended Solids) from the study area (26.5 ha), three scenarios were made in this study. It was found that runoff volume, peak runoff, and TSS could be reduced with infiltration manholes and pervious pavements to some degree. Although, there are many limitations in the analysis of LID effects on runoff and TSS, similar trends shown in this study would be expected with site-specific LID IMPs. Thus, it is strongly recommended that various site-specific LID IMPs, such as infiltration facilities, should be applied as much as possible for environment-friendly urban planning.

Low Impact Urban Development For Climate Change and Natural Disaster Prevention

  • Lee, Jung-Min;Jin, Kyu-Nam;Sim, Young-Jong;Kim, Hyo-Jin
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.54-55
    • /
    • 2015
  • Increase of impervious areas due to expansion of housing area, commercial and business building of urban is resulting in property change of stormwater runoff. Also, rapid urbanization and heavy rain due to climate change lead to urban flood and debris flow damage. In 2010 and 2011, Seoul had experienced shocking flooding damages by heavy rain. All these have led to increased interest in applying LID and decentralized rainwater management as a means of urban hydrologic cycle restoration and Natural Disaster Prevention such as flooding and so on. Urban development is a cause of expansion of impervious area. It reduces infiltration of rain water and may increase runoff volume from storms. Low Impact Development (LID) methods is to mimic the predevelopment site hydrology by using site design techniques that store, infiltrate, evaporate, detain runoff, and reduction flooding. Use of these techniques helps to reduce off-site runoff and ensure adequate groundwater recharge. The contents of this paper include a hydrologic analysis on a site and an evaluation of flooding reduction effect of LID practice facilities planned on the site. The region of this Case study is LID Rainwater Management Demonstration District in A-new town and P-new town, Korea. LID Practice facilities were designed on the area of rainwater management demonstration district in new town. We performed analysis of reduction effect about flood discharge. SWMM5 has been developed as a model to analyze the hydrologic impacts of LID facilities. For this study, we used weather data for around 38 years from January 1973 to August 2014 collected from the new town City Observatory near the district. Using the weather data, we performed continuous simulation of urban runoff in order to analyze impacts on the Stream from the development of the district and the installation of LID facilities. This is a new approach to stormwater management system which is different from existing end-of-pipe type management system. We suggest that LID should be discussed as a efficient method of urban disasters and climate change control in future land use, sewer and stormwater management planning.

  • PDF

A Study on Improvement of Hydrologic Cycle by Selection of LID Technology Application Area -in Oncheon Stream Basin- (LID 기술 적용 지역 선정에 따른 물순환 개선 연구 -온천천 유역을 대상으로-)

  • Kim, Jae-Moon;Baek, Jong-Seok;Shin, Hyun-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.545-553
    • /
    • 2021
  • The frequency by water disaster in urban areas are increasing continuously due to climate change and urbanization. Countermeasures are being conducted to reduce the damage caused by water disasters. An analysis based on permeability, one of the parameters that affect runoff, is needed to predict quantitative runoff in urban watersheds and study runoff reduction. In this study, the SWAT model was simulated for the oncheon stream basin, a representative urban stream in Busan. The permeability map was prepared by calculating the CN values for each hydrologic response unit. Based on the permeability map prepared, EPA SWMM analyzed the effect of LID technology application on the water cycle in the basin for short-term rainfall events. The LID element technology applied to the oncheon stream basin was rooftop greening in the residential complex, and waterproof packaging was installed on the road. The land cover status of the land selected based on the permeability map and the application of LID technology reduced the outflow rate, peak flow rate, and outflow rate and increased the infiltration. Hence, LID technology has a positive effect on the water cycle in an urban basin.

Application of LID to Reduce Storm Runoff according to the RCP Climate Change Scenarios (RCP 기후변화 시나리오에 따른 우수 유출량 저감을 위한 저영향개발 시설의 적용 방안)

  • Kim, Min ji;Kim, Ji Eun;Park, Kyung Woon;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.333-342
    • /
    • 2022
  • Due to climate change, increased heavy rainfalls result in flood damage every year. To investigate the storm-runoff reduction effects of Low Impact Development (LID), this study performed runoff analyses using the U.S. Environmental Protection Agency (EPA) Storm Water Management Model (SWMM) for past and future representative storm events of the Yongdu Rainwater Pumping Station basin. As a result, the infiltration loss for representative future rainfalls increased by 3.17 %, and the surface runoff and peak runoff rate increased significantly by 32.50 %, and 128.77 %, respectively. To reduce the increased surface runoff and peak runoff rates, this study investigated the applicability of LID approaches, including a permeable pavement, green roof, and rain garden, by adjusting the LID parameters and the ratio of installation area. We identified the ranges of LID parameters that decreased peak runoff rate and surface runoff, and increased infiltration. In addition, when the application ratio of permeable pavement, green roof, and rain garden was 2:1:3, best performance was attained, leading to a reduction of peak runoff of 26.85 %, infiltration loss 12.01 %, surface runoff 15.11 %, and storage 509.47 %. Based on analyzing the effect of storm runoff reductions for various return periods, it was found that as the return period increased, the proportion of peak runoff and surface runoff increased and the proportion of infiltration loss and storage decreased.

Water Balance Estimate of LID Technique for Circulating Urban Design (순환형 도시계획에 따른 LID기술의 물수지 분석)

  • Kang, Sung-Hee;Heo, Woo-Myung;Kang, Sang-Hyeok
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.1065-1073
    • /
    • 2015
  • Urbanization can be significantly affected the hydrologic cycle by increasing flood discharge and heat flux. In order to mitigate these modifications in urban areas, Low Impact Development (LID) technique has been designed and applied in Korea. In order to estimate runoff reduction rate using SWMM LID model, the characteristics of five LID techniques was firstly analyzed for water balance. Vegetated swale and green roof were not reduce flood discharge nor infiltration amount. On the other hand, porous pavement and infiltration trench were captured by infiltration function. The flood reduction rate with LID is substantially affected by their structures and properties, e.g., the percentage of the area installed with LID components and the percentage of the drainage area of the LID components.