• Title/Summary/Keyword: SWING MOTION

Search Result 330, Processing Time 0.028 seconds

A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain (만성요통환자의 보행특성에 관한 연구)

  • Kim, Kyoung;Ko, Joo-Yeon;Lee, Sung-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

Development of a Portable Gait Phase Detection System for Patients with Gait Disorders

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.145-150
    • /
    • 2005
  • A new gait detection system using both FSR (force sensing resistor) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the heel of a shoe. An algorithm was also developed to determine eight different gait transitions during four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was evaluated from nine heathy mans and twelve hemiplegic patients. Healthy volunteers were asked to walk in various gait patterns: level walking, fore-foot walking and stair walking. Only the level walking was performed in hemiplegic patients. The gait detection system was compared with a optical motion analysis system and the outputs of the FSR sensors. In healthy subjects, the developed system detected successfully more than $99\%$ for both level walking and fore-foot walking. For stair walking, the successful detection rate of the system was above$97\%$. In hemiplegic patients, the developed system detected approximately 98% of gait transitions. The developed gait phase detection system will be helpful not only to determine pathological gait phases but also to apply prosthetics, orthotics and functional electrical stimulation for patients with various gait disorders.

Dynamic Model Development and Simulation of Crawler Type Excavator (크롤러형 굴삭기의 동역학적 모델 개발 및 시뮬레이션)

  • Kwon, Soon-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.642-651
    • /
    • 2009
  • The history of excavator design is not long enough which still causes most of the design considerations to be focused on static analysis or simple functional improvement based on static analysis. However, the real forces experiencing on each component of excavator are highly transient and impulsive. Therefore, the prediction and the evaluation of the movement of the excavator by dynamic load in the early design stage through the dynamic transient analysis of the excavator and ensuring of design technique plays an importance role to reduce development-cost, shorten product-deliver, decrease vehicle-weight and optimize the system design. In this paper, Commercial software DADS and ANSYS help to develop the track model of the crawler type excavator, and to evaluate the performance and the dynamic characteristics of excavator with various simulations. For that reason, the track of crawler type excavator is modelled with DADS Track Vehicle Superelement, and the reaction forces on the track rollers were predicted through the driving simulation. Also, the upper frame and cabin vibration characteristics, at the low RPM idle state, were evaluated with engine rigid body modelling. And flexibility body effects were considered to determine the more accurate joint reaction forces and accelerations under the upper frame swing motion.

  • PDF

A Kinematical Analysis of the Kenmotsu on the Parallel Bars (평행봉 Kenmotsu 동작의 운동학적 분석)

  • Kong, Tae-Ung;Kim, Young-Sun;Yoon, Chang-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.61-70
    • /
    • 2005
  • The purpose of study was to investigate the kinematic variables of Kenmotsu motion in Parallel bars. To this study, by 3 dimensional kinematical analysis of 4 male national gymnasts participants in the 28th Athens Olympic Game in 2004, kinematic data collected using video camera. Coordinate data were smoothed by using a fourth-order Butterworth low pass digital filter with cutoff frequency of 6Hz. The conclusions were as follows. 1. In P2, because the constrained swing movement made the movement of a rising back difficult7, the movements of Reg. were performed at low position after Air phase. 2. In E5 event, for the shake of a stable handstand and applied techniques like a Belle(E-value), a Belle Piked(super E-value), a vertical velocity in E2, a horizontal velocity in E3 and a vertical velocity in E4 were necessary for high velocities. 3. In E4 event, it was appeared that for a flexible body's movement of a vertical up-flight, the large angle of the shoulder joint and the flexion & extension of the hip joint were necessary in Air phase and a long flight time and vertical displacement made Reg. movements stable at the high position.

Effect of Static Balance Performance on Gait in Elderly (노인의 정적 균형 수행력이 보행에 미치는 영향)

  • Kim Tae-Yoon
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.74-85
    • /
    • 2002
  • The purpose of this study was to investigate the effect of static balance performance on gait in elderly. Subjects were twenty four members living in Gwangju(12males, 12females), between 65 and 81 years of age. The Force platform was used to measured static balance performance and gait analyzed the 3-D Motion Analysis The results of this study were as follow ; 1. The postural sway showed, The mean value of toe-heel was $1.41\pm0.51cm$ and left-right was $063\pm0.20cm$. In gait analysis, the mean value of each variable were swing phase $40.5\pm9.65\%$, stance phase $59.5\pm9.65\%$, stride length 0.79m, cadence $0.83\pm0.44step/sec$, velocity $0.57\pm0.32m/sec$, Knee up $34.7\pm31.0^{\circ}$, Knee down $-53.6\pm40.14^{\circ}$. Ankle up $12.14\pm13.94^{\circ}$, Ankle down $-16.8\pm25.0^{\circ}$ showed. 2. The correlation matrix between L-R sway and Toe-heel sway and gait variables was not showed. 3. In multiple regression test, there were no related variable.

  • PDF

Car-door-controlled collision protection system using proximity sensor (근접센서를 이용한 차량 도어 제어 충돌 방지 시스템)

  • Lee S.H.;Cho H.S.;Heo J.K.;Lee J.H.;Kim W.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.971-975
    • /
    • 2005
  • In this study, a car-door-controlled collision protection system using proximity sensor is proposed and its preliminary analysis and several preliminary experiments are conducted. The proposed system has three additional sub-components on the car-door that is, a pair of extra electro-magnetic actuator that are attached to the sliding bar of the open/close car-door four-bar mechanism, a proximity sensor that would be attached to the outside surface of the door which is likely to frequently contact to the object and a driving control circuit of the whole system. A proximity sensor is used to detect object close to the car-door, the driving control circuit provides actuating power command to the electro-magnets to generate braking force to stop the swing motion of the car-door. It is verified through kinematic analysis of the four-bar car-door open/close mechanism and through experiments that the magnitude of maximum electronic magnetic force could provide the braking force enough for this application. For this purpose, an electro-magnet driving circuit is implemented and tested. And also to increase the safety of the system a time delay circuit is implemented and tested.

  • PDF

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

An efficient Bi-LSTM based method for outlier detection and correction in golf swing motion estimation (골프 스윙 모션 추정에서 Bi-LSTM 기반의 효율적인 이상치 검출 및 보정 기법)

  • Ju, Chan-Yang;Park, Ji-Sung;Oh, Gyeong-Su;Choi, Hyun-Jun;Lee, Dong-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.787-790
    • /
    • 2021
  • 본 논문에서는 최신 모션 인식 기술을 활용하여 골프 스윙 비디오에서 사람의 자세를 추정한 후 다양한 원인으로 오검출된 좌표들을 보정하여 자세 추정의 정확도를 높이는 방법을 제안한다. 기존의 사람 자세 추정 모델은 골프 스윙 데이터에서 오검출, 반전, 불안정성, 미검출의 문제를 보여 정확한 자세 추정을 어렵게 했다. 이를 해결하기 위하여 본 연구에서는 자세 추정시 발생하는 이상치 데이터들을 Bi-LSTM 으로 학습하고 골프 스윙의 특징을 고려한 간단한 규칙을 통하여 이상치 데이터를 효과적으로 검출하고 이를 보정하는 방법을 제안한다. 또한 다양한 실험과 분석을 통하여 제안하는 방법이 골프 스윙 모션에서 사람의 자세를 정확히 추정할 수 있음을 보인다.

Flexor Carpi Radialis Tendon Rupture due to Repetitive Golf Swing (반복적인 골프 스윙으로 인한 노쪽손목굽힘근 힘줄의 파열)

  • Lee, Sang Chul;Koh, Sung Hoon;Jang, Jin Hyuk;Ahn, Jae Ki
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.107-110
    • /
    • 2019
  • Flexor carpi radialis (FCR) muscle is located in the forearm anteriorly that runs through a synovial fibro-osseous tunnel in the forearm. We described a case of FCR tendon rupture due to repetitive overuse injury. A 55-year-old man, right-hand dominant, presented with right forearm pain and swelling which started 3 days ago while playing amateur golf. Focal tenderness and bruising over volo-ulnar region of the right forearm were examined. Plain radiographs showed soft tissue edema around lesion area and no detectable fracture. Ultrasonography showed multiple hypoechoic lesions suspected as hematoma of the flexor muscle group. After done magnetic resonance imaging, he was diagnosed with rupture of FCR tendon at proximal origin and strain of flexor digitorum superficialis and palmaris longus muscle. He received compressive dressing and restriction of wrist range of motion for three weeks. Two months later, remaining traces of lesions were observed at the follow-up ultrasonography and the pain disappeared.

A Kinematical Analysis of Belle Motion on Parallel Bars (평행봉 Belle 기술동작의 운동학적 분석)

  • Kong, Tae-Ung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.43-53
    • /
    • 2005
  • This study is to define how the difference of athletic change influence on the last regrasp after somersault in Belle movement of parallel bars. For his study, the following conclusion was produced by analysis of athletic change by means of three dimensional visual image in three athlete of nation. 1. As the picture of S1, there are total used time(2.01 sec), S3(2.17 sec) and S2(2.19 sec). In case of a short needed time, it is difficult for them to perform the remaining movement of the vertical elevating flight easily and comfortably, it is judged as performing the small movement with restrict swing. 2 In the change of body center sped by each event, it is calculated as $-89.1^{\circ}$ the narrowest in S1, $-81.96^{\circ}$ the widest and then $86.34^{\circ}$ in S3. In E3 event, average compound speed is 4.07m/s, S2 showed the fastest speed of 4.14m/s whereas S1 the narrowest angle of 3.95m/s. 3. A shoulder joint and coxa are the period of mention in E3. In E4 which was pointed out the longest vertical distance, S2 that is indicated the highest vertical height as the period of detach in parallel bars. showed -3.91m. This is regarded as a preparatory movement for dynamic performance after using effectively elastic movement of shoulder joint and coxa while easily going up with turning back movement. In the 5th phrase, long airborne time and vertical change position is showed as the start while regrasping securely air flight movement from high position. 4. In E5, a long flight time and a long vertical displacement were shown as the regrasp after somersault efficiently in high position with stability from the point of the highest peak of the center of the body. Especially, S2 is marked as a little bit long position, while S1 is reversely indicated as performing somersault and unstable motion in a low position. 5. In E3, at the point of the largest extension of the shoulder joint and hip joint the shoulder joint is largely marked in $182^{\circ}$ and the hip point $182^{\circ}$ in S2. The shoulder joint is marked at the smallest angle in $177^{\circ}$ and the hip point $176^{\circ}$ in S1. And S1 is being judged by its performance of the less self - confident motion with lessening a breath of swing. S2 makes the most use of flexion and extension of the shoulder joint and the hip joint effectively. It was performed greatly with swinging and dropping the rotary movement and the rotary inertia naturally. 6. In E6, as the point of regrasp of the upper arm in parallel bars it is recognized by the that of components of vertical and horizontal velocity stably. During this study, the insufficient thing and the study on the parallel bars at a real game later are more activated than now. If it is really used as the basic materials by means of Belle Picked Study of Super E level after Bell movement, you may perceive the technique movement previously and perform without difficulty. Especially, such technique as crucifix is quite advantageous for oriental people thanks to small body shape condition. In conclusion we will nicely prepare for our suitable environment to gradually lessen trials and errors by analyzing and studying kinematically this movement.