• Title/Summary/Keyword: SV

Search Result 1,123, Processing Time 0.027 seconds

Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB) (간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성)

  • Huh, Mock;Kang, Jin-Yuong;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • This study was carried out to develop INSUB(Indirected Aerated Submerged Biofilter) which can remove organics, nitrogen and phosphorus with an advanced treatment system. The results were as followed in laboratory model experiment. As for treatment of sewage, when economical efficiency was considered in practice, the highest removal efficiency was at 18hr of HRT, 1.017m/hr of superficial velocity and 40% of media packing ratio. Each removal efficiency for $COD_{cr}$, $COD_{Mn}$, $BOD_5$, T-N, and T-P was 90.6, 85.3, 95.0, 52.3 and 56.8%. To remove the nitrogen and phosphorus With high efficiency, first of all, denitrification have to be completed, then uptake of phosphorus have to completed. Therefor, mixture of anoxic and aerobic reactor was necessary for the high removal efficiency of nitrogen and phosphorus in INSUB.

  • PDF

EFFECT OF TEMPERATURE ON FLUORESCENCE QUENCHING BY STEADY STATE AND TRANSIENT METHODS IN SOME ORGANIC LIQUID SCINTILLATORS

  • Giraddi, T.P.;Kadadevarmath, J.S.;Chikkur, G.C.;Rath, M.C.;Mukherjee, T.
    • Journal of Photoscience
    • /
    • v.4 no.3
    • /
    • pp.97-103
    • /
    • 1997
  • The effect of temperature on the fluorescence quenching of 2-(4-Methoxyphenyl)-5-(1-naphthyl)-1,3,4-oxadiazole (MPNO1), 2-(4-Methoxyphenyl)-5-(2-naphthyl)-1,3,4-oxadiazote(MPNO2), by aniline, and 2-Phenylindole (2-PI) by CCk, in toluene by steady state method and in benzene by time-resolved method have been carried out in the temperature range 30 - 70$\circ$C. The Stem-Volmer (S-V) plots, I$_0$/I against quencher concentration [Q] at different temperanares show positive deviations. The fluorescence lifetimes determined at different temperatures show no systematic variations and the variations being within the experimental error, the average values of lifetimes $ $\tau$ (t) are taken for further calculations. Rate constants such as Stem-Volmer quenching constants K$_sv}$, quenching rate parameters k$_q$ and k'$_q$, static quenching constant V and kinetic distance r are determined using the modified Stem-Volmer equation and sphere of action static quenching model. In order to see whether the reactions are diffusion limited, equations k$_q$ = e$^{-Eq/RT}$ and k'$_q$ = e$^{-Eq/RT}$ are used to determine the values of E$_q$ and E'$_q$, the activation energies for collisional quenching and the values of E$_q$ are 14.53. 17.28 and 16.20 kJ mole$^{-1}$ for MPNO1, MPNO2 and 2-PI respectively and the values of E'$_q$ are 14.62 and 17.73 for MPNO1 and MPNO2 respectively. From the magnitudes of various quantities it has been concluded that the reactions are diffusion limited and the observed positive deviations in the S-V plot are due to static and dynamic quenching.

  • PDF

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.

Identification of Coupling and Repulsion Phase DNA Marker Associated With an Allele of a Gene Conferring Host Plant Resistance to Pigeonpea sterility mosaic virus (PPSMV) in Pigeonpea (Cajanus cajan L. Millsp.)

  • Daspute, Abhijit;Fakrudin, B.
    • The Plant Pathology Journal
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2015
  • Pigeonpea Sterility Mosaic Disease (PSMD) is an important foliar disease caused by Pigeonpea sterility mosaic virus (PPSMV) which is transmitted by eriophyid mites (Aceria cajani Channabasavanna). In present study, a F2 mapping population comprising 325 individuals was developed by crossing PSMD susceptible genotype (Gullyal white) and PSMD resistant genotype (BSMR 736). We identified a set of 32 out of 300 short decamer random DNA markers that showed polymorphism between Gullyal white and BSMR 736 parents. Among them, eleven DNA markers showed polymorphism including coupling and repulsion phase type of polymorphism across the parents. Bulked Segregant Analysis (BSA), revealed that the DNA marker, IABTPPN7, produced a single coupling phase marker (IABTPPN $7_{414}$) and a repulsion phase marker (IABTPPN $7_{983}$) co-segregating with PSMD reaction. Screening of 325 F2 population using IABTPPN7 revealed that the repulsion phase marker, IABTPPN $7_{983}$, was co-segregating with the PSMD responsive SV1 at a distance of 23.9 cM for Bidar PPSMV isolate. On the other hand, the coupling phase marker IABTPPN $7_{414}$ did not show any linkage with PSMD resistance. Additionally, single marker analysis both IABTPPN $7_{983}$ (P<0.0001) and IABTPPN $7_{414}$ (P<0.0001) recorded a significant association with the PSMD resistance and explained a phenotypic variance of 31 and 36% respectively in $F_2$ population. The repulsion phase marker, IABTPPN7983, could be of use in Marker-Assisted Selection (MAS) in the PPSMV resistance breeding programmes of pigeonpea.

Analysis of human HoxA gene control region and its effects on anterior-posterior axial pattern formation using transgenic mouse embryo (Transgenic mouse embryo를 이용한 human HoxA 유전자의 조절부위 분석과 전후축 형태형성(anterior-posterior axial pattern formation)에 미치는 영향)

  • Jang, Seung-ik;Min, Won-gi;Park, Jong-hoon;Lee, Chul-sang;Lee, Kyung-kwang;Lee, Young-won;Jun, Moo-hyung;Kim, Myoung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.1
    • /
    • pp.95-105
    • /
    • 1995
  • The human homolog of position specific element of mouse Hoxa-7 was studied using transgene. It contains a 1.1 kb human DNA (HCR)- a homolog to the intergenic region between Hoxa-7 and -9, which directs the position specific expression of Hoxa-7-, tk promoter, LacZ (${\beta}$-galactosidase) gene as a reporter, and polyadenylation signal of SV40 large T antigen. It was injected into the mice embryos, and the resulting transgenic embryos were analysed through PCR as well as genomic Southern blotting with placenta DNA. Out of 20 embryos analysed, two were transgenic. Among them, one transgenic embryo expressed transgene when stained with X-gal. The expression pattern was in analogy to that of the mouse Hoxa-7, showing spatially restricted expression pattern, Since the expression of ${\beta}$-galactosidase is regulated by the upstream human HCR sequence, it implies that the HCR is the plausible position specific regulatory element of human.

  • PDF

Selective Metal Ion Sensing of Bipyridine-Bisterpyridine containing Fluorescent Dyes (다중 피리딘 구조를 가지는 형광염료의 금속 이온 반응성에 대한 연구)

  • Zo, Hye Jin;Kim, Arong;Jeong, Sooyeon;Park, Jong S.
    • Textile Coloration and Finishing
    • /
    • v.25 no.4
    • /
    • pp.254-261
    • /
    • 2013
  • In this study, we synthesized a new fluorescent polypyridyl dye 2 containing a 2,2'-bipyridine in the center and two 2,2':6',2"-terpyridines at both ends. When exposed to various metal ions, the dye 2 showed selective fluorescence responses. In the presence of $Cu^{2+}$ and $Ni^{2+}$, it exhibited a highly effective fluorescence quenching, leading to large $K_{sv}$ values of up to $10^5$. In response to most other metal ions including $Al^{3+}$, in contrast, its fluorescence changes little, showing a small Ksv value at $10^2$. Meanwhile, the compound 2 revealed a differentiated fluorescence response to $Zn^{2+}$, which is evidenced by a large red shift of > 100 nm. Such a red shift from the ion binding is attributed to the planarization of the bipyridyl unit extending the effective conjugation length in conjunction. A polypyridyl compound will find important usefulness in chemosensor application due to its selective binding to metal ions. Subsequent research concerned with modified derivatives is currently going on, as a way to provide high solubility even after metal-complexing.

Development and Application of Radiological Risk Assessment Program RADCONS (방사능위해성평가 프로그램 RADCONS의 개발 및 적용)

  • Jeong, Hyojoon;Park, Misun;Hwang, Wontae;Kim, Eunhan;Han, Moonhee
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.89-97
    • /
    • 2013
  • RADCONS Ver. 1.0 (RADiological CONSequence Assessment Program) was developed for radiological risk assessment in this study. A Gaussian plume model was used to analyze the fate and transport of radionuclides released into the air in case of accidents. Both single meterological data and time series meterological data can be used in RADCONS. To assess the radiological risk of the early phase after an accident, ED (Effective Dose) estimated by both deterministic and probabilistic approaches are presented. These EDs by deterministic and probabilistic will be helpful to efficient decision making for decision makers. External doses from deposited materials by time are presented for quantifying the effects of mid and late phases of an accident. A radiological risk assessment was conducted using RADCONS for an accident scenario of 1 Ci of Cs-137. The maximum of ED for radii of 1,000 meters from the accident point was 8.51E-4 mSv. After Monte-Carlo simulation, considering the uncertainty of the breathing rate and dispersion parameters, the average ED was 8.49E-4, and the 95 percentile was 1.10E-3. A data base of the dose coefficients and a sampling module of the meteorological data will be modified to improve the user's convenience in the next version.

Preliminary Analysis of Dose Rate Variation on the Containment Building Wall of Dry Interim Storage Facilities for PWR Spent Nuclear Fuel (경수로 사용후핵연료 건식 중간저장시설의 격납건물 크기에 따른 건물 벽면에서의 방사선량률 추이 예비 분석)

  • Seo, M.H.;Yoon, J.H.;Cha, G.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.189-193
    • /
    • 2013
  • Annual dose on the containment building wall of the interim storage facility at normal condition was calculated to estimate the dose rate transition of the facility of PWR spent nuclear fuel. In this study, source term was generated by ORIGEN-ARP with 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facility and the containment building and radiation shielding evaluations were conducted by MCNP code depending on the distance between the wall and the facility in the building. In the case of the centralized storage system, the distance required for the annual dose rate limit from 10CFR72 was estimated to be 50 m.

DESIGN OPTIMIZATION OF RADIATION SHIELDING STRUCTURE FOR LEAD SLOWING-DOWN SPECTROMETER SYSTEM

  • KIM, JEONG DONG;AHN, SANGJOON;LEE, YONG DEOK;PARK, CHANG JE
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.380-387
    • /
    • 2015
  • A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as $^{235}U$, $^{239}Pu$, $^{241}Pu$, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux ($>10^{12}n/cm^2{\cdot}s$) neutron source comprised of a high-energy (30 MeV)/high-current (~2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (< $0.06{\mu}Sv/h$), a few shielding materials [high-density polyethylene (HDPE)eBorax, $B_4C$, and $Li_2CO_3$] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future.

Correlation Between Skin Roughness and Dermal Density of Skin Wrinkle Evaluation (피부 주름 평가에 있어서의 피부 거칠기와 진피 치밀도의 상관성 연구)

  • Lee, Hee-Kyung;Back, Ji-Hwoon;Koh, Jae-Sook;Park, Deok-Hoon;Lee, Jong-Sung;Jung, Eun-Sun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.2 s.57
    • /
    • pp.123-127
    • /
    • 2006
  • In this study, we evaluated the crow's fret of 95 Korean female by using mechanical assessments; Skin-Visiometer SV 600 and Dermascan C. Transparency profilometry (Skin Visiometer) were using a very thin skin print which allowed parallel light to pass through and was analysed immediately after production. High-frequency (20 MHz) ultrasonography (Dermascan C) enabled non-invasive evaluation in skin thickness and echodensity. We found a correlation between skin roughness and dermal density. Particularly, we showed a significant correlation between skin roughness (R2) and dermal thickness. Also, we demostrated a significant negative correlation between dermal density and dermal thickness (p < 0.05). Therefore, the ultrasonography system might be considered a very useful method in wrinkle evaluation with the transparency profilometry. Further study will be required.