• Title/Summary/Keyword: SV

Search Result 1,123, Processing Time 0.03 seconds

Environmental Radioactivity and High Incidence Rates of Stomach and Esophagus Cancer in the Van Lake Region: A Causal Relationship?

  • Akan, Zafer;Baskurt, Busranur;Asliyuksek, Hizir;Kam, Erol;Yilmaz, Ahmet;Yuksel, Mehmet Bilgehan;Biyik, Recep;Esen, Ramazan;Koca, Dogan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.375-380
    • /
    • 2014
  • This study examined the incidence rates of cancer cases (averages for 2006-2010) and relationships with environmental radioactivity levels. Soil and water samples were collected from provincial and district centers of Van city and the outdoor gamma doses were determined using a portable gamma scintillation detector. Gross alpha and beta, (226)Ra, (232)Th, and (40)K activities were measured in both tap water and soil samples. Although high rates of stomach and esophagus cancers have been reported previously in Van the underlying reasons have not hitherto been defined. Incidences of cancers were highest in the Gurpmar (326.0) and Ozalp (377.1) counties (p<0.001). As to the results of the gross alpha and gross beta radioactivity measurements in the drinking water, these two counties also had high beta radionuclide levels: Gurpmar ($140mBq/dm^3$) and Ozalp ($206mBq/dm^3$). Even if within the normal range, a relation between the higher rate of the incidence of stomach and esophagus cancers with that of the higher rate of beta radionuclide activity was clear. On Spearman correlation analysis, the relation between higher beta radionuclide levels and cancer incidence was found to be statistically significant (p<0.01). According to the results of the analysis, Van residents receive an average 1.86 mSv/y annual dose from outdoor gamma radiation, ingestion of radionuclides in the drinking water, and indoor $^{222}Rn$ activity. Moreover, gross alpha and beta activities were found to be extremely high in all of the lakes around the city of Van, Turkey. Further investigations with long-term detailed environmental radiation measurements are needed regarding the relationship between cancer cases and environmental radioactivity in the city of Van.

A Study on Removal of NOx in Diesel Engine using Reductive Catalyst (환원촉매를 이용한 디젤엔진 배기가스 중 NOx 저감에 관한 연구)

  • Huang, H.Z.;Hwang, J.W.;Jung, J.Y.;Han, J.H.;Demidiouk, V.I.;Chae, J.O.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2255-2261
    • /
    • 2000
  • To eliminate $NO_x$ in diesel emission. selective catalyst reduction (SCR) was used in real diesel engine. Among the SCR methods, metal oxide and perovskite catalysts were introduced in this paper. The removal efficiencies with various major, promoter catalysts on ${\gamma}-Al_2O_3$ at different reaction temperature were investigated, and $LaCuMnO_x$ catalyst which has high removal efficiency at the temperature of real diesel exhaust gas was selected. $NO_x$ reduction was carried out over these catalysts in the flow-through type reactor using by-pass ($SV=3,300h^{-1}$). Under the given condition to this study, perovskite catalysts showed considerably high removal efficiency and $LaCuMnO_x$ was the best one among these catalysts in the temperature range of $150{\sim}450^{\circ}C$.

  • PDF

IMMUNOHISTOCHEMICAL STUDY OF P21 AND P53 EXPRESSION IN AMELOBLASTOMA (법랑아세포종에서 p21 및 p53 발현에 관한 면역조직화학적 연구)

  • Shin, Dong-Joon;Myoung, Hoon;Hwang, Kyeng-Kyun;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.199-205
    • /
    • 2003
  • The p53 protein was discovered in 1979 as cellular 53-kD nuclear phosphoprotein bound to the large transforming antigen of SV40 virus. $P21^{WAF1/CIP1}$, which has been described as the critical downstream mediator of p53, is known to suppress DNA replication and arrest the G1 cell cycle by quaternary complex with cyclin D, cyclin-dependent kinase(CDK) and proliferating cell nuclear antigen(PCNA). In these days, some studies shows that the p21 can be induced by independent pathways. There are various reports about the expression of p21 (67%.82.4%) in oral squamous cell carcinoma. But these studies are mostly done in malignant tumor not in benign tumor. So we decided to study the expression of p21 in ameloblastoma and the relationship between p53 and p21 as a downstream mediator of p53 in ameloblastoma. We investigated the expression of p21 and p53 with the method of immunohistochemistry. We selected 30 cases of ameloblastoma tissue blocks (acanthomatous type: 5 cases, follicular type: 8 cases, plexiform type: 17 cases) imbedded in paraffin. We used 30 cases of normal gingival tissues and 30 cases of squamous cell carcinoma tissues (SCC) respectively and compared their results with those of ameloblastoma. We made slides with the streptavidin-biotin methods and used monoclonal antibody DO-7 (Novocastra, Newcastle, United Kingdom) as p53 antibody and monoclonal antibody M7202 (DAKO, California, U.S.A.) as p21 antibody. We used Pearson's correlation coefficient to analyse the relationship. The results were as follows: 1. p21 was expressed in ameloblastoma about 30% and this is lower than that of normal gingiva and SCC. 2. In normal gingiva and ameloblastoma, p21 expression was correlated with p53 expression. 3. In SCC, p21 were expressed about 83.3% and this is more than that of p53. But there was no correlation between p21 and p53 expression. We confirmed p21 expression and relation with p53 in ameloblastoma. But, to confirm the function of p21, more studies about p21 expression in malignant ameloblastoma and ameloblastic carcinoma are needed.

Wettability of titanium implants depending upon surface properties (타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구)

  • Han, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.12-20
    • /
    • 2009
  • Statement of problem: When an implant is fixed, a fixture comes into contact with a tissue fluid. Adhesion of a tissue fluid to a surface of implant is various case by case. Purpose: The ultimate goal of this work is to analyze a correlation between a surface roughness and wettability of implant specimens. A measurement for wettability is performed considering 4 types of specimen implant with surface treatments different from each other to investigate the change of wettability with the elapse of time. Material and methods: Firstly, 20 specimens of titanium were prepared. The specimen were made of a commercial Titanium Grade IV with the diameter of 10 mm and the thickness of 1 mm. According to the method of surface treatment, the specimens were classified into 4 groups of 5 specimens per group. Group A: Machined Surface Group B: Anodized surface Group C: RBM (HA blasting) surface Group D: CMP (calcium methaphosphate) coating surface. Surface roughness of specimen was measured using SV-3000S4 (Mituyoto, Japan). The measurement was based on the standard of JIS1994. Sessile drop method was used to measure the wettability, which measures contact angle between implant disc and saline with the time interval of 5, 10, and 15 seconds. SPSS 11.0 was used to analyze the collected data. In order to analyze the difference of wettability and surface roughness according to implant surface treatment method. The statistical significance was tested with the confidence level of 95%. Pearson's correlation coefficient was used to evaluate the correlation of surface roughness and wettability. Results: The difference of surface roughness was statistically significant in the order of Group C ($1.69{\pm}0.26$), Group D ($1.58{\pm}0.16$), Group B ($0.78{\pm}0.14$) Group A ($0.18{\pm}0.05$). The wettability has also a statistically significant difference, which was in the order of group B ($17.70{\pm}2.66$), Group C ($27.86{\pm}4.52$), Group D ($66.28{\pm}3.70$) Group A ($70.52{\pm}8.00$). There was no difference in wettability with the passage of time. Conclusions: 1. The surface roughness was high in the order of RBM, CMP, Anodized, Machined group (P<.05). 2. The wettability was high in the order of Anodized, RBM, CMP, Machined group (P<.05). 3. There was no statistical significance in the correlation of surface roughness and wettability.

Surface roughness changes caused by the galvanic corrosion between a titanium abutment and base metal alloy (티타늄 지대주와 비귀금속 합금사이의 갈바닉 부식에 의한 표면 거칠기 변화 평가)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Keun;Park, Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.65-72
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the level of electro-chemical corrosion and surface roughness change for the cases of Ti abutment connected to restoration made of base metal alloys. Materials and methods: It was hypothesized that Ni-Cr alloys in different compositions possess different corrosion resistances, and thus the specimens ($13{\times}13{\times}1.5\;mm$) in this study were fabricated with 3 different types of metal alloys, commonly used for metal ceramic restorations. The electrochemical characteristics were evaluated with potentiostat (Parstat 2273A) and the level of surface roughness change was observed with surface roughness tester. Paired t-test was used to compare mean average surface roughness (Ra) changes of each specimen group. Results: All specimens made of nickel-chromium based alloys, average surface roughness was increased significantly (P < .05). Among them, the Ni-Cr-Be alloy ($0.016{\pm}.007\;{\mu}m$) had the largest change of roughness followed by Ni-Cr ($0.012{\pm}.003\;{\mu}m$) and Ni-Cr-Ti ($0.012{\pm}.002\;{\mu}m$) alloy. There was no significant changes in surface roughness between each metal alloys after corrosion. Conclusion: In the case of galvanic couples of Ti in contact with all specimens made of nickel-chromium based alloys, average surface roughness was increased.

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

The Dependences of Magnetoresistance and Exchange Biasing on Annealing temperature in Top and Bottom Type Specular Spin Valves with Nano-oxide Layers (나노 옥사이드 층을 가진 스펙큘라 스핀밸브의 자기저항 특성 및 교환바이어스의 열처리 온도 의존성)

  • Jang, S.H.;Kang, T.;Kim, H.J.;Kim, K.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.103-108
    • /
    • 2002
  • We investigated magnetoresistance(MR) and exchange bias properties by annealing in top and bosom type spin valves (SV) with nano-oxide layers (NOL). In top SVs with NOL, MR ratio of 9.2% is obtained after postdeposition annealing at 250$\^{C}$. In bottom SVs with NOL, MR ratio of 10.1 % is obtained after postdeposition annealing at 250$\^{C}$. Therefore, specular reflection of the NOL in bottom SVs is higher than that of the NOL in top SVs. Exchange biasing of bottom SVs with NOL is 28% higher than that of bottom SVs without NOL after annealing. This enhancement of exchange biasing is thought to be due to the reduced magnetic moment of the pinned layer with NOL and enhanced (111) FeMn texture.

Treatment of Radioactive Liquid Waste Using Natural Evaporator and Resulted Exposure Dose Assessment (증발을 이용한 방사성 액체폐기물의 처리와 피폭선량평가)

  • Jeong, Gyeong-Hwan;Park, Seung-Kook;Kim, Eun-Han;Jung, Ki-Jung;Park, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.101-108
    • /
    • 1999
  • The influence of the relative humidity, the temperature and the velocity of supply air on evaporation rate has been studied with non-boiling forced evaporation system in order to treat very low level radioactive liquid wastes produced from the decontamination and decommissioning activities. Experimental data on the evaporation rate have been obtained with the divers variables and experimental equation of air velocity was also obtained by the correlation of those data. The decontamination factor of this system was also obtained by the experimental data from a simulated liquid waste containing Cs-137 radio isotope ; $DF=10^4$. Since the commercial system will be operated for the treatment of the very low level radioactive liquid waste produced from decontamination & decommissioning of TRIGA Mark-II&III research reactor, the environmental assessment has been conducted to improve the operational safety. Exposure dose rate for an individual member of general public was assessed, and it showed that it was very lower than individual dose limits. The release of radioactivity of radioisotope material (Cs-137) to the environment was assessed, and result showed that it was $4.637{\times}10^{-14}\;{\mu}Ci/cc$.

  • PDF

Factors Predicting Early Release of Thyroid Cancer Patients from the Isolation Room after Radioiodine-131 Treatment

  • Fatima, Nosheen;Zaman, Maseeh uz;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia;Shahid, Wajiha
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.125-129
    • /
    • 2016
  • Background: Patients with differentiated thyroid cancers (DTC) who receive radioactive iodine-131 (RAI) are released from isolation when their dose rate is below the regulatory requirements. The purpose of this study was establish predicting factors for early release from the isolation facility after RAI administration in patients with DTC. Materials and Methods: This was a prospective study which included 96 (58 females and 38 males) patients with DTC who had received RAI from April 2013 till August 2015. The study was duly approved by the ethical committee of the institute. Patients who had complete information of primary tumor size (PTS), serum TSH, stimulated thyroglobulin level [sTg] with antibodies (IU/ml) at the time of RAI treatment were included. All had a normal serum creatinine level. To attain lower effective half-life good hydration and administration of soft laxative were ensured. Dose rate was measured (immediately, 24 h and 36 h) at 1 meter distance from anterior mid trunk and a dose rate <$50{\mu}Sv/h$ was considered as the releasing criterion. At 24 h 50 patients were released while the remaining 46 patients were released at 36 h. A post-ablative whole body scan (PA-WBIS) was performed 5-8 days after RAI ablation in all patients. Results: Patients released after 24 h were significantly younger, had smaller lesions with higher proportion of papillary cancer, lower sTg, lower sTg/TSH ratio and had received a lower dose of RAI as comapred to those who were discharged after 36 h. Serum TSH and gender were not found to have any significant correlation between two cohorts. ROC and multivariate analysis have shown age ${\leq}37years$, PTS ${\leq}3.8cm$, $RAI{\leq}150mCi$, $sTg{\leq}145ng/ml$ and $sTg/TSH{\leq}1.085$ as strong indepedent predictors for early release. Conclusions: We conclude that younger age (${\leq}37years$), smaller tumor size (${\leq}3.8cm$), lower RAI dose (${\leq}150mCi$), lower sTg (${\leq}145ng/ml$) and a lower sTg/TSH ratio (${\leq}1.085$) are significant independent predictors for release at 24 h after RAI treatment in DTC patients. Effective utilization of these factors could help the treating physicians to use limited number of internment facilities with higher throughput, lower cost and lower psychological stress to patients.

Evaluation of Cardiac Function Analysis System Using Magnetic Resonance Images

  • Tae, Ki-Sik;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo;Shinn, Kyung-Sub;Jung, Seung-Eun;Lee, Jae-Moon
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 1999
  • Cardiac disease is one of the leading causes of death in Korea. In quantitative analysis of cardiac function and morphological information by three-dimensional reconstruction of magnetic resonance images, left ventricle provides an important role functionally and physiologically. However, existing procedures mostly rely on the extensive human interaction and are seldom evaluated on clinical applications. In this study, we developed a system which could perform automatic extraction of enpicardial and endocardial contour and analysis of cardiac function to evaluate reliability and stability of each system comparing with the result of ARGUS system offered 1.5T Siemens MRI system and manual method performed by clinicians. For various aspects, we investigated reliability of each system by compared with left ventricular contour, end-diastolic volume (EDV), end-systolic volume (ESV), stock volume (SV), ejection fraction (EF), cardiac output (CO) and wall thickness (WT). When comparing with manual method, extracted results of developed process using minimum error threshold (MET) method that automatically extracts contour from cardiac MR images and ARGUS system were demonstrated as successful rate 90% of the contour extraction. When calculating cardiac function parameters using MET and comparing with using correlation coefficients analysis method, the process extracts endocardial and epicardial contour using MET, values from automatic and ARGUS method agreed with manual values within :t 3% average error. It was successfully demonstrated that automatic method using threshold technique could provide high potential for assessing of each parameters with relatively high reliability compared with manual method. In this study, the method developed in this study could reduce processing time compared with ARGUS and manual method due to a simple threshold technique. This method is useful for diagnosis of cardiac disease, simulating physiological function and amount of blood flow of left ventricle. In addition, this method could be valuable in developing automatic systems in order to apply to other deformable image models.

  • PDF