• Title/Summary/Keyword: SUS평가

Search Result 92, Processing Time 0.026 seconds

A Study on the Drilling Characteristics for Implant Procedure Drill (임플란트 시술용 드릴의 가공 성능 평가에 관한 연구)

  • Lee, Sang-Min;Chae, Seung-Su;Lee, Jae-Kun;Choi, Hwan;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.49-54
    • /
    • 2014
  • Skull Melted 3.2YSZ has good physical properties and does not undergo low temperature degradation. Due to these excellent physical and mechanical properties, Skull Melted 3.2YSZ has been studied for use in dental implants. In this study, a ø2.2mm Initial Twist Drill was made using Skull Melted 3.2YSZ; the drilling characteristics were compared with those of the traditional SUS420J drill. The experimental results indicate that the Skull Melted 3.2YSZ drill requires similar thrust forces and has a slightly higher temperature.

TiMo 합금타겟을 이용하여 음극 아크 공정으로 제조된 TiMoN 박막의 기초실험 및 분석

  • Kim, Seong-Hwan;Yang, Ji-Hun;Byeon, In-Seop;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.94.1-94.1
    • /
    • 2017
  • 최근 공구산업은 산업 발전으로 특수합금들이 발달하면서 이를 가공할 수 있는 새로운 절삭공구소재들이 개발되어 지고 있다. 또한 공구소재보다 코팅개발이 상대적으로 더욱 효과적이기 때문에 코팅 기술 개발이 활발히 진행되고 있다. 최근 일본에서는 새로운 코팅층 물질 개발보다는 기존의 코팅물질을 조합하거나 개량하여 성능을 향상시키는 추세이다. 또한 다기능 절삭 공구를 지속적으로 사용하는 추세에 따라 공구설계의 새로운 솔루션이 요구된다. 예를 들어 TiN 코팅과 추가 요소를 합금하면 효과적인 경도, 내마모성 등을 향상시키며, TiAlN, TiSiN 등을 예로 들 수 있다. 반면, 기존 TiN에 Mo가 첨가된 TiMoN 박막은 특성화하기 위한 노력이 매우 제한적이었다. Mo가 함유된 코팅층의 특징은 낮은 마찰 계수를 갖는다. 이는 Mo이 공기중의 산소와 반응하여 MoO3를 형성하기 때문이다. 본 연구에서는 TiMo합금 타겟을 음극 아크 증착공정을 이용하여 기초실험을 진행하고 분석평가를 진행하였다. 공정조건은 본 실험실에서 도출한 TiN의 기본공정조건을 바탕으로 기초실험을 진행하였으며, 시편은 스테인리스 강판(SUS304)을 사용하였다. 기초분석은 SEM, EDS, XRD, 초미소경도를 이용하였다. 처음 TiMo합금 타겟을 이용하여 기초실험과 분석을 진행한 결과 TiN과 비슷할 것으로 예상한 것과는 다른 결과가 관찰되었으며, 최적화 된 공정도출을 위한 향후 실험을 계획중이다.

  • PDF

Design of Diaphragm for Ultra High Pressure Sensors and Its performance Evaluation Using a PZT Actuated Deformation Tester (초고압 압력센서용 다이어프램 설계 및 PZT 구동 변형시험기를 이용한 성능평가)

  • Yun, Dae Jhoong;Ahn, Jung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • This research aims at designing a diaphragm made of SUS316L stainless steel for ultra high pressure sensors and evaluating its performance with a PZT driven deformation tester instead of high pressure chamber testing up to 100 MPa. Finite element method analysis indicates that the optimum thickness of a flat diaphragm is 1.5 mm not only to secure safety of sensors up to 100 MPa but also to enhance displacement measuring sensitivity. For this thickness, the maximum displacement at the center of the diaphragm is $5.3{\mu}m$. The PZT actuator must offer a force of 1,669 N to create a pressure of 100 MPa at the diaphragm surface in order to obtain a displacement of $5.3{\mu}m$. The performance evaluation by the PZT driven tester demonstrates nearly the same results as the same results as the sensors tested in the ultra high pressure chamber.

The study of Rolled Steel Process Wastewater by Superconducting High Gradient Magnetic Separation (초전도 마그네트를 이용한 고구배 자기분리 열연강판 폐수처리에 관한 연구)

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Kwon, Jun-Mo;Lee, Nam-Jin;Kim, Young-Hun;Kang, Chae-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-11
    • /
    • 2009
  • 종래의 산업폐수 처리기술로는 중금속 함유 폐수에 수용성의 금속염을 첨가하여 가성소다 혹은 소석회를 이용하여 pH를 조정하고 고분자 응집제를 첨가하여 금속의 수산화물을 생성시켜 이를 부상 혹은 침전시켜 Sludge화하여 제거하는 방법이 주로 사용되고 있다. 그 외 질소, 인, 유기물이 함유된 폐수의 경우에는 Biological Oxidation Techniques, 활성탄 흡착방식이 주로 채택되고 있다.[1-3] 이러한 폐수처리기술은 화학약품 사용량이 과다하고 이는 Sludge 생성량을 증대하고 2차 폐수처리가 필요로 하는 경우가 많고, 처리장이 면적이 넓어야 하고 대용량의 Sludge 제거창치가 필요하여 고비용의 처리공정으로 문제점을 가지고 있다.[2-3] 이에 본 연구에서는 이러한 기존 기술의 문제점을 보완할 수 있고 기존 기술로는 완벽하게 처리하기 곤란한 악성 폐수들에 대한 새로운 고도처리기술로 초전도 마그네트를 이용한 고구배 자기분리기술에 대한 기초연구를 하였다. 본 연구에서 사용한 고구배 자기분리 시스템은 무헬륨 전도냉각방식으로 자기분리를 위해 사용한 필터는 SUS 430 재질의 메쉬 형태로 제작하여 실험하였다. 또한, 자기분리 처리를 위한 전처리 공정으로는 응집제를 첨가하여 자기분리 효율을 높이고자 하였다. 자기분리 처리대상수로는 포항제철에 압연 강판에 사용되는 냉각수를 대상으로 자기분리 처리에 대한 효과를 실험하였다. 또한, 자기분리에 대한 특성을 평가하기 위해 강자성의 $Fe_3O_4$ 미세자성분말을 첨가하여 처리수내의 들어있는 유기물질에 대해 자기분리 자장 및 유속에 대한 처리효율을 미치는 영향을 조사하였다. 자기분리 처리는 1~6 Tesla에서 자기필터는 디스크 형태로 다층으로 연속적으로 적층하였으며, 처리유속은 1~4 l/min으로 하였다. 고농도인 처리폐수를 자가분리 인가 자장에 따라 처리하여 고농도에서는 70%, 저농도에서는 98 %까지 처리되었다. 또한, 자기분리용 필터는 SUS 430 재질의 mesh 망을 사용하였으며 인가자장 및 유속변화에 대한 실험 결과 탁도 및 농도는 필터 크기의 영향은 거의 차이가 없었으며 단지 인가자장 및 유속에 따라서 지수적으로 감소하였다. 자기분리된 용액 내 $Fe_3O_4$ 입도 분석 결과 자기분리 이전에 분포하던 $10\sim20\;{\mu}m$의 입자는 거의 제거되었으며 2 ${\mu}m$ 이하의 입자들은 실험 횟수에 따라 점점 직경이 작은 쪽으로 분포가 좁아졌으며, 마그네타이트의 자화율을 분석한 결과 약 0.8 Tesla에서 포화 되었으며 처리수의 탁도 및 농도가 자장에 따라 감소하는 것으 알 수 있었다.

  • PDF

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis (근전의수용 소형 표면 근전위 센서의 개발)

  • Choi, Gi-Won;Sung, So-Young;Moon, Inhyuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.67-76
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for the myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket for the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is. composed of a skin interface and a single processing circuit that are mounted on a single package. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

Characteristics of Anode-supported Flat Tubular Solid Oxide Fuel Cell (연료극 지지체식 평관형 고체산화물 연료전지 특성 연구)

  • Kim Jong-Hee;Song Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Anode-supported flat tubular solid oxide fuel cell (SOFC) was investigated to increase the cell power density. The anode-supported flat tube was fabricated by extrusion process. The porosity and pore size of Ni/YSZ ($8mol\%$ yttria-stabilized zirconia) cermet anode were $50.6\%\;and\;0.23{\mu}m$, respectively. The Ni particles in the anode were distributed uniformly and connected well to each other particles in the cermet anode. YSZ electrolyte layer and multilayered cathode composed of $LSM(La_{0.85}Sr_{0.15})_{0.9}MnO_3)/YSZ$ composite, LSM, and $LSCF(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.7}O_3)$ were coated onto the anode substrate by slurry dip coating, subsequently. The anode-supported flat tubular cell showed a performance of $300mW/cm^2 (0.6V,\; 500 mA/cm^2)\;at\;500^{\circ}C$. The electrochemical characteristics of the flat tubular cell were examined by ac impedance method and the humidified fuel enhanced the cell performance. Areal specific resistance of the LSM-coated SUS430 by slurry dipping process as metallic interconnect was $148m{\Omega}cm^2\;at\;750^{\circ}C$ and then decreased to $148m{\Omega}cm^2$ after 450hr. On the other hand, the LSM-coated Fecralloy by slurry dipping process showed a high area specific resistance.

Stress Distribution in Microvascular Anastomotic Coupler (AnaFix®) Micropins with Respect to the Fillet Radius (필렛효과에 따른 미세혈관 문합커플러(AnaFix®) 마이크로핀의 응력분포)

  • Jee, Dae-Won;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1139-1145
    • /
    • 2011
  • An automated anastomotic ring-pin system consisting of both the anastomotic ring-pin system and the coupler device has eliminated the drawbacks of the suture method. High density polyethylene (HDPE), a material with outstanding biocompatibility and injection molding capability, was used in the ring. SUS316 stainless steel, Ti-6Al-4Nb, Ti-6Al-4V, and unalloyed titanium were used in FEM simulations of the micropin. The authors categorized the microvascular anastomotic ring micropins into short neck (SN) and long neck (LN) groups in order to evaluate the effect of the micropin's fillet radius and neck length on the von Mises stress. The micropins were further divided into those with and without fillet. On the basis of the fillet radius rate (FRR), which represents the rate of change in the von Mises stress with respect to the availability and shape of the fillet, and the neck length rate (NLR), which represents the rate of change in the von Mises stress with respect to changes in the length of the neck within the fillet shape, it can be concluded that the SN-3 neck design is the most stable.

Usability test of pulling cable exercise machine in the spinal cord injury disabled: Focusing on deriving improvement (척수 손상 장애인 대상 장애인용 풀링 케이블 운동기구의 사용성 평가: 개선점 도출을 중심으로)

  • Sung Shin Kim;Myo Jung Choi;Hyosun Kweon;Kwang Ok An;Young-Hyeon Bae
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.16-32
    • /
    • 2024
  • Background: Exercise equipments and assistive devices for the disabled are being developed, but improvements for usability are still needed. The purpose of this study was to improve and utilize the developed exercise equipment and assistance devices by conducting usability test for people with spinal cord injury. Design: Cross-sectional Study. Methods: Scenarios and usability indicators were derived by conducting a preliminary usability test, 5 non-disabled men and women aged 19 or older. In the scenario, a total of 9 tasks were sequentially performed, including 2 tasks of entry and exit, 5 tasks of assistance devices and weight stack adjustment, and 2 tasks of pre exercise and exercise. The usability indicators were task success (success or fail), execution time (sec), safety, and convenience. For safety, 7 questions (Likert scale, 1~5 point) related to safety, stability and hazard were derived, and for convenience, the system usability scale (SUS score) was used (range: 0~100, 50 percentile rank is 68 point). Results: As a result of the usability test of people with spinal cord injury, there was a large variation among subjects in the task of adjusting the position of the pulley and support in the execution time (11.64~25.44 seconds), and one person failed to adjust the pulley. The safety level showed a lower score (score = 3 points) than other items in the item of entrapment or skin pressure, and in the case of SUS, the average score was 64.5 points, which was close to the acceptable level. Conclusion: Through the usability test, it was confirmed that exercise equipment for the disabled needs improvement in operability, pinching, and pressure, and that it is necessary to develop an assistive device that provides unrestrained posture information (biofeedback) to maintain correct posture during exercise.

UBM 스퍼터링법으로 코팅한 벌크비정질합금(BMG) 박막의 특성 연구

  • Park, Hye-Seon;Yang, Ji-Hun;Jeong, Jae-Hun;Song, Min-A;Jeong, Jae-In;Sin, Seung-Yong;Mun, Gyeong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.335-335
    • /
    • 2013
  • 최근 다기능 소재의 개발이 필요함에 따라 서로 상반되는 2가지 이상의 물성을 동시에 구현할 수 있는 소재의 개발이 요구되고 있다. 4 성분계 물질을 단일 타겟으로 제조함으로써 다수의 타겟을 이용하는 기존 PVD 방법의 복잡성과 재형성 등의 문제점을 해결하고 다기능성을 구현할 수 있는 코팅막을 제조할 수 있게 된다. 본 연구에서는 제조된 4 성분계 모물질을 UBM 최근 다기능 소재의 개발이 필요함에 따라 서로 상반되는 2가지 이상의 물성을 동시에 구현할 수 있는 소재의 개발이 요구되고 있다. 4 성분계 물질을 단일 타겟으로 제조함으로써 다수의 타겟을 이용하는 기존 PVD 방법의 복잡성과 재형성 등의 문제점을 해결하고 다기능성을 구현 할 수 있는 코팅막을 제조할 수 있게 된다. 본 연구에서는 제조된 4 성분계 모물질을 UBM 스퍼터링법을 이용하여 질화 공정을 도출하였고 질소 함량에 따른 물리적 특성 및 박막의 특성에 대해 연구하였다. BMG (Bulk Metallic Glass) 타겟을 이용하여 마그네트론 스퍼터링법으로 박막을 코팅하였다. 시편은 Si wafer, SUS 그리고 부식 특성 평가를 실시하기 위하여 냉연강판을 사용하였다. 시편은 아세톤, 알코올로 각각 10분간 초음파 세척한 후 진공장비에 장착하여 Ar 분위기에서 글로우 방전으로 청정을 30분간 실시하였다. 시편청정이 끝나면 ~$10^{-6}$ Torr까지 진공 배기를 실시하고 Ar 가스를 주입하여 2.5 mTorr로 진공도를 유지하여 스퍼터링으로 박막 코팅을 실시하였다. 스퍼터링 파워는 약 0.6 kW (2.0 A)으로 고정하였고 질소 유량은 0~10 SCCM으로 변화시켜 BMG 박막을 코팅하였다. 질소가 첨가된 BMG 박막에서는 시편의 색상이 노란빛으로 나타났으며 이것은 타겟의 조성 중 가장 많이 함유되어있는 Zr이 질화되어 색상의 변화가 일어난 것으로 판단된다. BMG 코팅을 위해서 진공용기로 주입한 질소의 유량이 소량인 경우에도 BMG 코팅층에 비교적 많은 양의 질소가 존재하였고 일정량 이상에서는 BMG 코팅층에 존재하는 질소의 양이 포화되는 현상을 보였다. 질소 유량 3, 4 SCCM의 BMG 코팅층에서 ZrN (111), ZrN (200) Peak이 관찰되었다. BMG 코팅층의 경도 측정결과 Bias 50 V 인가 시 ~22 Gpa로 경도가 가장 높았다. BMG 코팅층의 내부식 특성을 평가하기 위해 염수분무 시험을 실시하였고 ~$10{\mu}m$의 두께를 갖는 BMG 코팅층에서 염수분무 시작 후 48시간 만에 적청이 발생하였다.

  • PDF

TiN/NiTi 2층형 박막의 두께 변화에 따른 물리적 특성 기초연구

  • Byeon, In-Seop;Yang, Ji-Hun;Kim, Seong-Hwan;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.132-132
    • /
    • 2018
  • NiTi 형상 기억 합금은 형상기억 효과 (Shape memory effect) 또는 초탄성 효과 (superelasticity effect)를 나타낸다고 알려져 있다. 대표적으로 Ni:Ti 조성비가 1:1을 갖는 NiTi(니티놀) 합금은 형상기억 및 초탄성 효과가 우수하여 기계 가공 공정뿐만 아니라 우수한 내마모성을 요구하는 공구에 사용하기 적합하다. 하지만 NiTi 박막은 합금과 같은 Damping capacity를 가지고 있지만 비교적 낮은 물리적 특성을 가지고 있다. 본 연구에서는 NiTi 박막의 낮은 물리적 특성을 향상시키기 위하여 TiN과 NiTi의 2층형 박막을 제조하고 각 층의 두께 변화를 조절하여 특성 향상에 대한 기초연구를 진행했다. 타겟은 NiTi (Ni:Ti=48.2:51.8 at.%) 합금 타겟과 Ti 타겟을 사용하였고, 시편과 타겟 간의 거리는 약 10cm 이며, 시편은 기초분석을 위한 SUS304, 물리적 특성 평가를 위한 초경 을 사용하였다. 초경은 실제 공구에서 사용하고 있는 Co함량이 10% 함유된 시편은 선정했다. 시편 전처리는 알코올과 아세톤으로 세척을 실시한 후 진공챔버에 장착하고 ${\sim}10^{-5}Torr$ 까지 진공배기를 실시하였다. 기판 정청은 글로우 방전 방식으로 약 800 V 전압에서 30분간 실시했다. 공정 가스는 Ar와 $N_2$ 혼합가스를 사용하였으며, UBM(Un-Balanced Magnetron) 스퍼터링 소스를 이용하여 2층형 박막을 제조했다. TiN과 NiTi 층의 두께 비율을 0.5, 1 그리고 2 로 변화시켜 코팅했으며, 박막의 총 두께는 약 ${\sim}3{\mu}m$ 이다. 기초분석은 FE-SEM을 통해 두께와 박막 비율을 확인 및 XRD 분석을 통해 박막 정성분성을 실시했다. 2층형 박막의 물리적 특성은 Nanoindentation test, AFM 및 ball on disc를 이용하여 평가했으며, 그 결과 두께 비율 변화에 따라 물리적 특성 변화가 나타남을 확인했다.

  • PDF