• Title/Summary/Keyword: STX8

Search Result 53, Processing Time 0.022 seconds

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom (호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교)

  • Kim, Seong-Eun;Won, Hui-Su;Hong, Joo-Wan;Chang, Nam-Jun;Jung, Woo-Hyun;Choi, Byeong-Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Purpose : The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. Materials and Methods : The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Results : Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54~2.33, 5.16~8.06, 9.03~20.11 ml in MIP, respectively, 0.00~1.48, 0.00~8.47, 1.42~24.85 ml in MinIP, respectively and 0.00~1.17, 0.00~2.19, 0.04~3.35 ml in AVG, respectively. Conclusion : After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  • PDF

Identification of bacterial agents causing mastitis in dairy cattle and observation of residual changes of sulfadimethoxine in serum and milk of the cattle after administration of sulfadimethoxine sodium (유방염 우에서 원인균분리 및 sulfadimethoxine sodium 투여 후 혈청 및 유즙내 잔류량 추이)

  • 조민희;도재철;송희종;정종식
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.1
    • /
    • pp.31-41
    • /
    • 2001
  • This study was carried out to identify causative agents from california mastitis test(CMT) positive mastitic milk, and to examine the antimicrobial susceptibility of 50 heads in Seongju and Chilgok area of Gyeongbuk province. Sulfadimethoxine sodium(SMS) was intramuscularly administered once to four mastitis Infected dairy cattle at the rate of 10mg/kg body weight. After injection of SMS, the depletion rate of serum and milk from the cattle were periodically measured for five days. The CMT positive number from 50 heads showed 46% and that of 200 quarters was 47(23.5%). From 39 quarters of 47 heads 39 different microorganisms were identified. These organisms were classified into 12 species : Staphylococcus aureus 8(20.5%), Sta hemolyticus 6(15.4%), Streptococcus bovis 4(10.3%), Sta hyicus 3(7.7%), Sta epidemidis. Sta xylosus, Sta sciuri 2(5.1%), Str agalactiae 2(5.1%), Escherichia coli(10.3%), three Enterobacter cloacae(7.7%), two Ent aerogenes(5.1%) and one Salmonella spp(2.6%). As the results of antibiotic susceptibility test, gentamicin(Gm, 11 species 27 strains, 69.5%), cephalotin(Cf, 9 species 24 strains, 61.5%), sulfamethoxazole(Stx, 8 species 14 strains, 43.6%), tetracycline(Tc, 8 species 14 strains, 35.9%), and streptomycin(Sm), lincomycin(Lm), cefoperazon(Cp) and penicillin(Pc) have a highly resistance(7.7% ~5.1%). However, carbenicillin (Cb), amikacin(Ah) have no susceptible for all drugs. The mean residual concentration of SMS in serum according to the time lapsed were showed 33.964 $\pm$ 4.435ppm at the 4 hours after intramuscularly injection(AII). It was significantly(p<.05) decreased to 6.596 $\pm$ 3.402, 0.217 $\pm$ 0.119 and 0.005 $\pm$ 0.004ppm at the 1st, 3rd and 5th day AII. The mean concentration of SMS in milk was significantly(p<.05) decreased from 0.920 $\pm$ 0.42ppm to 0.084 $\pm$ 0.016ppm between 8 hours and 1 day AII. As the results of this experiments, sulfadimethoxine was residued at the level of no less than 0.01ppm in milk on the 2nd day AII. Thus, this results would be able to be used the basic index for prevention of sulfonamides residue in milk after treatment of dairy mastitis.

  • PDF

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Studies for Reestabilishment of Approval Toxin Amount in Paralytic Shellfish Poison-Infested Shellfish 5. Comparison of Toxicity and Toxin Composition of Paralytic Shellfish Poison between Blue mussel, Mytilus edulis and Oyster, Crassostrea gigas

  • Shin, Il-Shik;Kim, Young-Man
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.287-292
    • /
    • 2000
  • The toxicity and toxin composition between blue mussel, Mytilus edulis and oyster, Crassostrea gigas collected at Woepori in Ko je island in South Coast of Korea in 1996 and 1997 were compared. The highest toxicity score was about 10 times higher in blue mussel than oyster (blue mussel, 8,670 $\mu\textrm{g}$; oyster, 860$\mu\textrm{g}$ in 1996, blue mussel, 5,657 $\mu\textrm{g}$/100g in 1997). The blue mussel also retained its toxicity for slightly longer period than oyster. In the both shellfish, PSP was composed almost exclusively of C toxicity (Cl and C2, 20~65%) and gonyautoxins (GTXl, 2, 3, and 4, 38~78%). In the early period of toxin accumulation, the ratio of 11$\beta$-epimer toxins (C2, GTX4) whose amount was 25~56 mole% (5th March to 12th April in 1996) and 25~80 mole% (18th March to 7th April in 1997), were higher than that of 11-epimer toxins (Cl, GTX2) whose amount was 41~57 mol%(27th May to 3rd June in 1996) and 25~56 mole% (29th April to 12th May in 1997), became higher than that of 11-epimer toxins. The toxin compositions in the both samples changed on a daily basis, presumably owing to metabolism of the toxin in the bivalves.

  • PDF

Antecedents and Consequences of Supplier's fairness perception (중소공급업체 공정성 지각의 선행요인과 결과요인)

  • Kim, Do-Heon;Kim, Sang-Deok
    • Journal of Distribution Science
    • /
    • v.9 no.2
    • /
    • pp.61-72
    • /
    • 2011
  • The object of this research is to examine the factors leading to intercompany win-win by finding the antecedents and consequences that affect a supplier's fairness perception. We assume that the antecedent factors of a supplier's fairness perception are vertical coordination, cooperation support, information sharing, and legalistic plea. We assume that the consequential factors of a supplier's fairness perception are supply chain dependence and supply chain flexibility. The object industry is an electronic parts manufacturing company. We tested our model by using the SPSS 17.0 and the LISREL 8.5. For measurement validation, we verified by using a confirmatory factor analysis and a reliability analysis. For hypothesis analysis, we did a path analysis with the LISREL 8.5. By checking the modification index and expecting parameter changes, we modified the model. First, the buyer's vertical coordination had a positive effect on the supplier's distributive fairness perception and procedural fairness perception. Second, the buyer's cooperation support had no effect on the supplier's distributive fairness perception and procedural fairness perception: we suppose that the buyer's requests were burdensome, although they cooperated with the supplier. Third, the buyer's information sharing had a positive effect on distributive fairness perception but had no direct effect on procedural fairness perception. Fourth, the buyer's legalistic plea had a negative effect on the supplier's distributive fairness perception. and a negative effect on the supplier's procedural fairness perception at a 0.1 significance level. Fifth, although procedural fairness perception had no direct effect on supply chain dependence, fairness perception had an effect on supply chain dependence and supply chain flexibility both directly and indirectly.

  • PDF

STUDY ON MONITORING UNIT EFFICIENCY OF FLATTENING-FILTER FREE PHOTON BEAM IN ASSOCIATION WITH TUMOR SIZE AND LOCATION

  • Kim, Dae Il;Kim, Jung-In;Yoo, Sook Hyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.194-201
    • /
    • 2013
  • To investigate monitoring unit (MU) efficiency and plan quality of volumetric modulated arc therapy (VMAT) using flattening-filter free (FFF) photon beam in association with target size and location. A virtual patient was generated in Eclipse$^{TM}$ (ver. A10, Varian Medical Systems, Palo Alto, USA) treatment planning system. The length of major and minor axis in axial view was 50 cm and 30 cm, respectively. Cylindrical-shaped targets were generated inside that patient at the center (symmetric target) and in the periphery (asymmetric target, 7.5 cm away from the center of the patient to the right direction) of the virtual patient. The longitudinal length was 10 cm and the diameters were 2, 5, 10 and 15 cm. Total 8 targets were generated. RapidArc$^{TM}$ plans using TrueBeam STx$^{TM}$ were generated for each target. Two full arcs were used and the axis of rotation of the gantry was set to be at the center of the virtual patient. Total MU, homogeneity index (HI), target mean dose, the value of gradient measure and body mean dose were calculated. In the case of symmetric targets, averaged total MU of FFF plan was 23% and 19% higher than that of flattening filter (FF) plan when using 6 MV and 10 MV photons, respectively. The difference of HI, target mean dose, gradient measure and body mean dose between FF and FFF was less than 0.04, 2.6%, 0.1 cm and 2.2%, respectively. For the asymmetric targets, total MU of FFF plan was 21% and 32% was higher than that of FF when using 6 MV and 10 MV photons, respectively. The homogeneity of the target was always worse when using FFF than using FF. The maximum difference of HI was 0.22. The target mean dose of FFF was 3.2% and 4.1% higher than that of FF for the 6 MV and 10 MV, respectively. The difference of gradient measure was less than 0.1 cm. The body mean dose was higher when using FFF than FF about 4.2% and 2.8% for the 6 MV and 10 MV, respectively. No significant differences between VMAT plans of FFF beam and FF beam were observed in terms of quality of treatment plan. The HI was higher when using FFF 10 MV photons for the asymmetric targets. The MU was increased noticeably when using FFF photon beams.

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Detection of Cytolethal Distending Toxin and Other Virulence Characteristics of Enteropathogenic Escherichia coli Isolates from Diarrheal Patients in Republic of Korea

  • Kim, Jong-Hyun;Kim, Jong-Chul;Choo, Yun-Ae;Jang, Hyun-Chul;Choi, Yeon-Hwa;Chung, Jae-Keun;Cho, Seung-Hak;Park, Mi-Seon;Lee, Bok-Kwon
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.5
    • /
    • pp.525-529
    • /
    • 2009
  • Cytolethal distending toxins (CDTs) represent an emerging family of newly described bacterial products that are produced by a number of pathogens. The genes encoding these toxins have been identified as a cluster of three adjacent genes, cdtA, cdtB, and cdtC, plus 5 cdt genetic variants, designated as cdt-I, cdt-II, cdt-III, cdt-IV, and cdt-V, have been identified to date. In this study, a general multiplex PCR system designed to detect Escherichia coli cdts was applied to investigate the presence of cdt genes among isolates. As a result, among 366 E. coli strains, 2.7% were found to carry the cdtB gene. In addition, the use of type-specific primers revealed the presence of cdt-I, cdtIV, and cdt-V types of the cdt gene, yet no cdt-II or cdt-III strains. The presence of other virulence genes (stxl, stx2, eae, bfp, espA, espB, and espD) was also investigated using a PCR assay. Among the 10 cdtB gene-positive strains, 8 were identified as COT-producing typical enteropathogenic E. coli (EPEC) strains ($eae^+$, $bfp^+$), whereas 2 were identified as CDT-producing atypical EPEC strains ($eae^+$, $bfp^-$). When comparing the cytotoxic activity of the CDT-producing typical and atypical EPEC strains, the CDT-producing atypical EPEC strains appeared to be less toxic than the CDT-producing typical EPEC strains.