• Title/Summary/Keyword: STROBE

Search Result 32, Processing Time 0.033 seconds

Reporting Guidelines for Health Promotion Research (건강증진 연구 보고지침)

  • Yoo, Seung-Hyun
    • Korean Journal of Health Education and Promotion
    • /
    • v.29 no.4
    • /
    • pp.83-99
    • /
    • 2012
  • Objectives: The purpose of this review is to introduce reporting guidelines for health promotion research in an effort to enhance systematic structure and quality of health promotion research reported in academic papers. Methods: Widely accepted guidelines were selected for description, which focus on 4 distinct types of research design. Checklists and flow diagrams are described and compared. Results: CONSORT Statement is reporting guidelines for randomized controlled trials with a 25-item checklist and a flow diagram. TREND Statement with a 22-item checklist is to guide reporting of health research in nonrandomized design. STROBE Statement is a compiled guidelines for observational health research, accompanied by a 22-item checklist in a combined edition. PRISMA Statement consists of a 27-item checklist and a flow diagram, providing guidelines for reporting systematic reviews and meta-analyses. All items on the checklists and flow diagrams were introduced and discussed. Conclusion: Solid understanding of research designs and adoption of reporting guidelines will enhance the quality of research with information on internal and external validity. Education and training of researchers on the research reporting is required along with systems level adoption of efforts for research enhancement.

Study on Spray Characteristics of GCSC Injector with Recess in High Pressure Condition (고압조건에서 기체-액체 분사기의 리세스에 따른 분무 특성 연구)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Choi, Hwan-Seok;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.57-60
    • /
    • 2011
  • The spray characteristics according to the recess length of the GCSC injector and the change of momentum flux ratio(MFR) of the gas and the liquid have been examined through high pressure cold flow test using a high pressure chamber. The liquid in this experiment was water, and the gas was nitrogen. The spray images were taken by a back-lit strobe imaging technique. Results showed that the spray was a wide hollow cone at the lower MFR(liquid velocity was fixed) and the spray became a narrow solid cone as the MFR was increased. And the injector with short recess length produced a narrow solid cone at the higher MFR.

  • PDF

Analysis and Detection Method for Line-shaped Echoes using Support Vector Machine (Support Vector Machine을 이용한 선에코 특성 분석 및 탐지 방법)

  • Lee, Hansoo;Kim, Eun Kyeong;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.6
    • /
    • pp.665-670
    • /
    • 2014
  • A SVM is a kind of binary classifier in order to find optimal hyperplane which separates training data into two groups. Due to its remarkable performance, the SVM is applied in various fields such as inductive inference, binary classification or making predictions. Also it is a representative black box model; there are plenty of actively discussed researches about analyzing trained SVM classifier. This paper conducts a study on a method that is automatically detecting the line-shaped echoes, sun strobe echo and radial interference echo, using the SVM algorithm because the line-shaped echoes appear relatively often and disturb weather forecasting process. Using a spatial clustering method and corrected reflectivity data in the weather radar, the training data is made up with mean reflectivity, size, appearance, centroid altitude and so forth. With actual occurrence cases of the line-shaped echoes, the trained SVM classifier is verified, and analyzed its characteristics using the decision tree method.

Quality Assessment Tools and Reporting Standards in Nursing Research (간호연구 질 평가 도구 및 보고지침 고찰)

  • Kim, Kyunghee;Kim, Joo Hyun;Lim, Kyung-Choon;Lee, Kyung-Sook;Jeong, Jae-Sim;Choe, Myoung-Ae;Chae, Young Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.3
    • /
    • pp.221-230
    • /
    • 2012
  • Purpose: Quality of nursing research should be evaluated before it is applied as an evidence for evidence-based nursing practice. This study attempted to analyze and to compare tools for the quality assessment and reporting standards of nursing research using CONSORT and STROBE checklist by types of research design. Methods: We searched the tools for quality assessment in nursing research based on the National Evidence-based Healthcare Collaborating Agency (NECA) publication. Then, we analysed and compared the tools for quality evaluation by types of research design. Results: According to the analysis using CONSORT checklist, ROB shows coherence in 17 items, Jadad shows coherence in 3 items, SIGN (for RCT) shows coherence in 26 items, and Downs & Black shows coherence in 24 items. According to the analysis using STROBE checklist, MINORS shows coherence in 25 items, NOS shows coherence in 21 items, SIGN (for Cohort studies & Case-control studies) shows coherence in 29 items, and RoBANS shows coherence in 21 items. Conclusion: Based on our analysis, we recommend that nursing researchers should report according to the reporting standards of tools for quality evaluation. We hope that our analysis can be helpful to develop evidence-based nursing.

Development of a Test Stand for Measuring Ink Jetting Performance (잉크젯 토출 특성 평가 장치 개발)

  • Kwon, Kye-Si
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.45-50
    • /
    • 2008
  • An ink jetting measurement system has been developed such that the velocity as well as the volume of ink droplets can be measured. In order to measure the ink droplet, a strobe LED light was synchronized to the droplet firing signal in order to obtain frozen droplet images. Then, a LabVIEW based software was developed for the analysis of the droplet image. For the efficient droplet analysis, a user generated rectangular shaped ROI (Region of Interest) was used. By using ROI, the ink droplet image can be easily isolated from the other structures such as printhead and the processing area can be minimized.

Development of a Sensor System for Real-Time Posture Measurement of Mobile Robots (이동 로봇의 실시간 자세 추정을 위한 센서 시스템의 개발)

  • 이상룡;권승만
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2191-2204
    • /
    • 1993
  • A sensor system has been developed to measure the posture(position and orientation) of mobile robots working in industrial environments. The proposed sensor system consists of a CCD camera, retro-reflective landmarks, a strobe unit and an image processing board. The proposed hardware system can be built in economic price compared to commercial vision systems. The system has the capability of measuring the posture of mobile robots within 60 msec when a 386 personal computer is used as the host computer. The experimental results demonstrated a remarkable performance of the proposed sensor system in the posture measurement of mobile robots - the average error in position is less than 3 mm and the average error in orientation is less than 1.5.

The development of the landmark tracking system

  • Lee, Eun Ho;Dickerson, Steve
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1894-1898
    • /
    • 1991
  • A landmark tracking system(LTS) has been developed for use in locating objects in a manufacturing environment. The Landmark Tracking System is an integrated system which consists of a grey scale CCD camera, an image processor, an illumination system based on electronic flash, and software intended primarily for tracking retroreflective landmarks. The term "integreated" means that the camera electronics and the strobe electronics are directly linked to the computer system, governed by the same clock and under direct software control. A novel element in the LTS is that a pinhole is used for the optics.he optics.

  • PDF

Diagnosis and monitoring of inkjet operating conditions (잉크젯 작동 상태 진단 및 모니터링)

  • Kwon, Kye-Si;Kim, Byung-Hun;Kim, Sang-Il;Shin, Seung-Joo;Kim, Seong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.455-460
    • /
    • 2007
  • A self-sensing circuit for piezo inkjet has been designed in order to monitor the operating condition during printing. In order to verify the circuit, both ink droplet images from strobe LED and vibration signals from the laser vibrometer were measured and compared with self-sensing signal. Experimental results show that self-sensing signal was effective in detecting the pressure wave change due to the bubble trapped in inkjet printhead.

  • PDF

Visualization of Electro-hydrodynamic Ink Jetting using CCD Camera (CCD 카메라를 사용한 전기수력학적 잉크젯 토출 현상 가시화)

  • Kwon, Kye-Si;Lee, Dae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.3
    • /
    • pp.295-301
    • /
    • 2012
  • The method for spraying of liquids through an electrical field has become a printing method since it can make very small droplet. For electro-hydrodynamic jet printing to become a reliable jetting tool, the jetting performance should be characterized with respect to various jetting conditions. To optimize jetting conditions, the jetting behavior should be measured. In this study, we present a visualization techniques to measure jetting behavior from electro-hydrodynamic (EHD) inkjet head. Unlike most previous method, we use the CCD camera to measure the jetting behavior. For this purpose, LED light is synchronized with jetting signal and sequential image was obtained by adjusting the delay time of the LED light. Finally, merits and demerits of using CCD camera were discussed to measure jetting image from EHD inkjet head.

The study of correlation between forward head posture and shoulder pain: A STROBE-compliant cross-sectional study

  • Kim, Hyun-Joong;Lee, DongJin
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.251-256
    • /
    • 2021
  • Objective: The forward head posture (FHP) is strongly related to the rounded shoulder posture (RSP), which is associated with shoulder pain. Design: Observational cross sectional study design Methods: A total of 37 were enrolled in the study, 22 individuals with FHP(experimental group) and 15 healthy adults(control group). Correlation with differences between groups was analysed through craniovertebral angle (CVA) representing FHP for both groups, neck disability index (NDI) indicating neck pain, disability of the arm, shoulder and hand (DASH) indicating shoulder pain. Results: There was a significant difference in the results of CVA, NDI, and DASH in FHP and healthy adults (p<0.05). Significant correlations were found between DASH and CVA in FHP participants (r = -0.656, p = 0.001). Also, in the regression analysis results of DASH and CVA, the regression model was found to be suitable and the variation in DASH could be explained by 43% (F = 15.118, p = 0.001). Conclusions: Shoulder pain and neck discomfort are potentially related, and an increase in shoulder pain can increase FHP.