• 제목/요약/키워드: STRIDE

검색결과 460건 처리시간 0.024초

스트라이드와 쉬프트를 사용한 데이터 값 예측기 (Data Value Predictor using Stride and Shift)

  • 최재혁;정진하;윤완오;신광식;최상방
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 컴퓨터소사이어티 추계학술대회논문집
    • /
    • pp.235-238
    • /
    • 2003
  • Conventional stride predictor is useful for predicting data values which vary by a constant value. However, when the data values of shift, multiplication, and division instructions are predicted, the stride predictor can't show the best performance. Thus, we propose predictor using stride and shift to improve predictability. The predictor using stride and shift takes advantage of shift values as well as stride values, so that the overall coverage of prediction increases.

  • PDF

Validity of a Portable APDM Inertial Sensor System for Stride Time and Stride Length during Treadmill Walking

  • Tack, Gye Rae;Choi, Jin Seung
    • 한국운동역학회지
    • /
    • 제27권1호
    • /
    • pp.53-58
    • /
    • 2017
  • Objective: The purpose of this study was to compare the accuracy of stride time and stride length provided by a commercial APDM inertial sensor system (APDM) with the results of three dimensional motion capture system (3D motion) during treadmill walking. Method: Five healthy men participated in this experiment. All subjects walked on the treadmill for 3 minutes at their preferred walking speed. The 3D motion and the APDM were simultaneously used for extracting gait variables such as stride time and stride length. Mean difference and root mean squared (RMS) difference were used to compare the measured gait variables from the two measurement devices. The regression equation derived from the range of motion of the lower limb was also applied to correct the error of stride length. Results: The stride time extracted from the APDM was almost the same as that from the 3D motion (the mean difference and RMS difference were less than 0.0001 sec and 0.0085 sec, respectively). For stride length, mean difference and RMS difference were less than 0.1141 m and 0.1254 m, respectively. However, after correction of the stride length error using the derived regression equation, the mean difference and the RMS difference decreased to 0.0134 m and 0.0556 m or less, respectively. Conclusion: In this study, we confirmed the possibility of using the temporal variables provided from the APDM during treadmill walking. By applying the regression equation derived only from the range of motion provided by the APDM, the error of the spatial variable could be reduced. Although further studies are needed with additional subjects and various walking speeds, these results may provide the basic data necessary for using APDM in treadmill walking.

Multi-Stride Decision Trie for IP Address Lookup

  • Lee, Jungwon;Lim, Hyesook
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권5호
    • /
    • pp.331-336
    • /
    • 2016
  • Multi-bit tries have been proposed to improve the search performance of a binary trie by providing flexibility in stride values, which identify the number of bits examined at a time. However, constructing a variable-stride multi-bit trie is challenging since it is not easy to determine a proper stride value that satisfies the required performance at each node. The aim of this paper is to identify several desired characteristics of a trie for IP address lookup problems, and to propose a multi-stride decision trie that has these characteristics. Simulation results using actual routing sets with about 30,000 to 220,000 prefixes show that the proposed multi-stride decision trie has the desired characteristics and achieves IP address lookup using 33% to 47% of the 2-bit trie in the average number of node accesses, while requiring a smaller amount of memory.

스마트 기기를 활용한 보행속력에 따른 맞춤보폭의 적용 (Adaptation of Customized Measurement of Stride Length in Smart Device)

  • 이병문
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.35-43
    • /
    • 2013
  • 생활 속에서 걷기(보행)와 같은 운동을 보다 효과적으로 할 수 있다면 비만과 같은 생활습관 질병과 체중을 관리하는데 도움이 된다. 일반적으로 소모 칼로리는 보행시 이동하는 거리를 기준으로 계산된다. 그러나 보행거리는 보폭과 걸음수로 측정될 수 있는데, 대부분의 운동량 측정 계에서는 평균보폭을 기준으로 삼아 측정하고 있어 각기 다른 개인의 신체적 특성과 보행특성을 제대로 반영하지 못하고 있다. 뿐만 아니라 보행속력에 따라서 보폭도 달라지기 때문에 보행속력을 고려하지 않는다면 보행거리가 길수록 오차가 점점 커져 잘못된 보행거리와 칼로리 소모량이 계산될 수밖에 없다. 이에 본 연구에서는 개인의 보행속력을 3단계로 분류하고 3축 가속도계로부터 측정된 x,y,z축 값으로 보행속력을 추정한 뒤 보폭을 자동으로 계산해 내는 개인별 자동보폭 측정기법을 고안하였다. 또한 측정기법의 유효성을 확인하기 위해 스마트 기기에서 애플리케이션을 개발하고, 이를 이용한 인식률 실험과 보행속력 분류 정확도 실험, 그리고 이동거리 측정실험을 통해서 그 효용성을 확인할 수 있었다.

젊은 성인에서 경사로 보행 시 스마트폰 사용이 보행 변수에 미치는 영향 (Effects of the Gait Variable While Using Smartphones During Ramp Gait in Young Adults)

  • 윤채효;김범수;강도영;김연서;이명희
    • PNF and Movement
    • /
    • 제19권2호
    • /
    • pp.261-267
    • /
    • 2021
  • Purpose: This study aimed to investigate changes in gait variables depending on whether a task was performed using a smartphone while walking on a ramp. Methods: The participants of this study were 41 college students attending U University located in Gyeongju City, Gyeongsangbuk-do. In this study, gait variables were measured during ramp gait while using a smartphone to perform a task and during ramp gait without performing such tasks. In other words, four walking conditions were used: 1) walking up a ramp, 2) walking up a ramp while using a smartphone to perform a task, 3) walking down a ramp, and 4) walking down a ramp while using a smart phone to perform a task. Gait variables were measured using a gait analysis tool (Legsys; BioSensics, USA), and stride time, stride length, stride velocity, cadence, and double support were analyzed. The order of measurements was randomized to control for order effects due to repeated measurements. Results: The comparative analysis of gait variables according to the presence or absence of smartphone use during ramp gait showed that there were significant differences in stride time, stride length, and stride velocity during both ramp ascent and ramp descent (p < 0.05). In both ramp ascent and ramp descent, stride time increased when walking using a smartphone, compared to when walking without using a smartphone (p < 0.05). However, in both ramp ascent and ramp descent, stride length and stride velocity were decreased when walking using a smartphone compared to when walking without using a smartphone (p < 0.05). Conclusion: The study results showed that the use of a smartphone during walking can affect safety. Therefore, it is necessary to improve the awareness of risks associated with walking while using a smartphone, and further research needs to be conducted in various environments and with different ramps.

Changes of Gait Variability by the Attention Demanding Task in Elderly Adults

  • Yeo, Sang Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제29권6호
    • /
    • pp.303-306
    • /
    • 2017
  • Purpose: Gait variability is defined as the intrinsic fluctuations which occur during continuous gait cycles. Increased gait variability is closely associated with increased fall risk in older adults. This study investigated the influence of attention-demanding tasks on gait variability in elderly healthy adults. Methods: We recruited 15 healthy elderly adults in this study. All participants performed two cognitive tasks: a subtraction dual-task (SDT) and working memory dual-task (WMDT) during gait plus one normal gait. Using the $LEGSys^+$ system, we measured the coefficient of variation (CV %=$100{\times}$[standard deviation/mean]) for participants' stride time, stride length, and stride velocity. Results: SDT gait showed significant increment of stride time variability compared with usual gait (p<0.05), however, stride length and velocity variability did not difference between SDT gait and usual gait (p>0.05). WMDT gait showed significant increment of stride time and velocity variability compared with usual gait (p<0.05). In addition, stride time variability during WMDT gait also significantly increased compared with SDT gait (p<0.05). Conclusion: We reported that SDT and WMDT gait can induce the increment of the gait variability in elderly adults. We assume that attention demanding task based on working memory has the most influence on the interference between cognitive and gait function. Understanding the changes during dual task gait in older ages would be helpful for physical intervention strategies and improved risk assessment.

STRIDE 위협 모델링 기반 가상 사설망 취약점 분석 및 보안 요구사항 도출 (Analyze Virtual Private Network Vulnerabilities and Derive Security Guidelines Based on STRIDE Threat Modeling)

  • 김다현;민지영;안준호
    • 인터넷정보학회논문지
    • /
    • 제23권6호
    • /
    • pp.27-37
    • /
    • 2022
  • 디지털 통신 환경 기술이 다양화되고 네트워크 이용 접근성이 높아지고 있으며 보안이 중요한 방산업체, 국방 관련 기관 등 국가의 안보에 관련된 다양한 환경에서 가상 사설망 서비스를 사용한다. 하지만 기술에 발전에 따라 매년 가상 사설망의 취약점을 통한 공격이 증가하고 있다. 본 논문은 가상 사설망에서 발생 가능한 잠재적 취약점 및 신규 취약점에 대해 대비하기 위해 STRIDE 위협 모델링을 통해 보안 요구사항을 도출하였다. STRIDE 위협 모델링은 위협을 총 6가지 범주로 그룹화 위협을 체계적으로 식별한다. 이를 적용하기 위해 가상 사설망의 기능을 분석하고 가상 사설망 서비스가 이루어지는 동안의 자료 흐름도를 생성하였다. 그 후, 가상 사설망에서 발생 가능한 위협을 수집하고 이를 기반으로 STRIDE 위협 모델링을 분석했다. 생성한 가상 사설망의 자료 흐름도는 총 96개의 STRIDE 위협으로 분류되며, 실제 취약점 리스트와 비교 분석하여 분류 결과를 구체화했다. 그 후 위협들의 공격 루트를 파악하기 위해 위협 시나리오를 작성했다. 본 논문은 작성된 시나리오를 기반으로 가상 사설망의 구성요소에 따른 총 30개의 보안 요구사항을 도출했다. 본 논문을 통해 국방부와 같이 보안이 중요한 시설에서 사용하는 가상 사설망의 보안 안정성을 높일 수 있는 보안요구사항을 제시한다.

트레드밀을 이용한 보행간 Variability 분석에 관한 연구 (A Study on Stride-to-stride Variability by Treadmill Walking)

  • 최진승;강동원;탁계래
    • 한국운동역학회지
    • /
    • 제17권4호
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study was to investigate the difference in the stride-to-stride variability between two treadmill conditions; traditional treadmill and special treadmill whose speed can be adjusted automatically by subject's walking speed. Eight male subjects (25.1 years, 172.7 cm, 66.6 kg) were participated in treadmill walking experiment. First, preferred walking speed (PWS) of each subject was determined. Second, each subject performed walking experiment with fixed PWS condition and with free PWS condition for 10 minutes. 3D motion capture system (Motion analysis Corp., USA) with 6 cameras was used to collect motion data with sampling frequency of 120Hz. Temporal and spatial variables for stride-to-stride variability were calculated. Coefficient of variance (CV) which quantifies the amount of variability and Detrended Fluctuation Analysis (DFA) which explains the structure (self-similarity) of the variability were used for analysis. Results showed that the amount of variability during free PWS condition was greater than that of fixed PWS condition. DFA results showed that there was a statistical difference between two treadmill conditions for the variables of step length, stance time, and double support time. From these results, it is possible that traditional treadmill study might give incorrect conclusion about gait variability study. Further study is necessary to clarify these matters by considering the number of subjects, experimental time, and gait variables for the study of stride-to-stride variability.

광학적 분석방법을 이용한 보폭측정 (Measurement of Stride Length Using Optical Method)

  • 정구인;전재훈;이강휘;송민선
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1116-1122
    • /
    • 2008
  • Since conventional methods for measuring stride length(distance) are many weaknesses, optical methods have been developed to measure stride length(distance) of human pedestrians. IR(Infrared) elements and Power LED(Light Emitting Diode) with two types of lens were used to correlate detected light intensity with stride length(distance). The suggested methods in this study are simple, convenient, and cost effective. The results can be used to analyze walking patterns of normal and disabled men, and to monitor the recovering processes of the disabled patients.