• Title/Summary/Keyword: STL 파일

Search Result 59, Processing Time 0.034 seconds

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

Optimization of Build Parameters in SLS Process (SLS의 공정 파라미터 최적화에 관한 연구)

  • Heo, Seong-Min;O, Do-Geun;Choe, Gyeong-Hyeon;Lee, Seok-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.769-776
    • /
    • 2000
  • RP(Rapid Prototyping) technology is gaining its popularity in building a prototype in all industries. SLS(Slective Laser Sintering) is one of RP technologies, which is focused on tooling processes as well as three dimension solid model. There are several factors, the length and the cross-sectional area of a part, that have an effect on build setup in SLS process. In this paper, the computation on geometrical relationship is used to slice STL file and to estimate these factors. Based on these values, the build setup parameters such as the heating temperature, the laser power, and the powder cartridge feed rate are determined by neural network approaches. The test results show that the computation time is saved and the neural network approach is able to apply to get the optimal parameters of build process within an acceptable error rate.

Evaluation of the dimensional change of 3D-printed complete denture after post-curing (후경화에 따른 3차원 프린팅 의치의 체적변화)

  • Suyeon, Lee;Younghun, Kwak;Eunchul, Park;Heejung, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.233-241
    • /
    • 2022
  • Purpose: The purpose of this study was to assess the dimensional change of 3D-printed dentures after post-curing. Materials and Methods: The upper and lower dentures were designed in Exocad DentalCAD software and exported as STL files. The upper and lower dentures were printed from 10 STL files using a DLP-type dental 3D printer. The printed upper and lower dentures were cleaned, and a scan file was created using a model scanner before and after post-curing. The dimensional change was evaluated by superimposing the scanned denture files before and after post-curing and measuring the distance between measurement points on the denture. SPSS was used for statistics, and the level of significance was 5%. Results: The maxillary denture reduced in size during post-curing, with the most notable color change occurring in the posterior palatal region. The reduction in anteroposterior maxillary denture length (A-D, A-E, A-F), as well as the distance between the first molars on both sides (B-C), was statistically significant. After post-curing, the mandibular denture showed more noticeable color change in the posteriorly buccal and lingual region. The decrease of length on the posterior (A-M, A-D, A-E, A-L, A-H, A-I, H-I) and lingual (J-K, L-M) sides of the denture were statistically significant. Conclusion: There was significant dimensional change in both the length and width of the 3D-printed maxillary and mandibular dentures after post-curing in this experiment. Consequently, it is seemed necessary to develop post-curing techniques and materials that reduce such denture deformation.

The Implementation of the Digital watermarking for 3D Polygonal Model (3차원 형상 모델의 디지털 워터마킹 구현)

  • Kim, Sun-Hyung;Lee, Sun-Heum;Kim, Gee-Seog;Ahn, Deog-Sang
    • The KIPS Transactions:PartD
    • /
    • v.9D no.5
    • /
    • pp.925-930
    • /
    • 2002
  • This paper discusses techniques for embedding data into 3D polygonal models of geometry. Much researches of Watermarking had been gone as element technology of DRM (digital rights management). But, few research had gone to 3D polygonal model. Most research is limited at text document, 2D image, animation, music etc. RP system is suitable a few production in various goods species, and it is used much in industry to possible reason that produce prototype and find error or incongruent factor at early stage on design in product development childhood. This paper is research about method that insert watermark in STL ( stereolithography) file that have 3D shape model. Proposed algorithm inserts watermark in normal vector region and facet's interior region of 3D shape data. For this reason, 3D shape does not produce some flexure and fulfill invisibility of watermark. Experiment results that insert and extract watermark in normal netter region and facet's Interior region of 3D shape data by proposed algorithm do not influence entirely in 3D shape and show that insertion and extraction of watermark are possible.

Rapid Prototyping from Reverse Engineered Geometric Data (리버스 엔지니어링으로 생성된 데이터를 이용한 쾌속 조형 기술 연구)

  • Woo, Hyuck-Je;Lee, Kwan-Heng
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.95-107
    • /
    • 1999
  • The design models of a new product in general are created using clay models or wooden mock-ups. The reverse engineering(RE) technology enables us to quickly create the CAD model of the new product by capturing the surface of the model using laser digitizers or coordinate measuring machines. Rapid prototyping (RP) is another technology that can reduce the product development time by fabricating the physical prototype of a part using a layered manufacturing technique. In reverse engineering process, however, the digitizer generates an enormous amount of point data, and it is time consuming and also inefficient to create surfaces out of these data. In addition, the surfacing operation takes a great deal of time and skill and becomes a bottleneck. In rapid prototyping, a faceted model called STL file has been the industry standard for providing the CAD input to RP machines. It approximates the CAD model of a part using many planar triangular patches and has drawbacks. A novel procedure that overcomes these problems and integrates RE with RP is proposed. Algorithms that drastically reduce the point clouds data have been developed. These methods will facilitate the use of reverse engineered geometric data for rapid prototyping, and thereby will contribute in reducing the product development time.

  • PDF

Study on the Laser Scanning Path Creation Time of Rapid prototype Using Jewellery Data (쥬얼리 데이터를 이용한 쾌속조형장치의 주사경로 생성 시간에 관한 연구)

  • 한민식;김태호;김민주;이준희;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.190-193
    • /
    • 2004
  • This paper presents studies on the creation time of scanning path using rapid prototype device. In the case of Jewellery, it needs to take time too much at the whole process of rapid prototype in accordance with heigh of the multi-layered. When increases the number of polygon by heigh of the Multi-layered, it has proper influence on the creation time of scanning path. Therefore, we can get the spending time and the number of polygon for the creation during increase the heigh of the multi-layered. These values are showed by the quantitative. We try to analyze relation between these and heigh of the multi-layered.

  • PDF

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

Development of Physical Human Bronchial Tree Models from X-ray CT Images (X선 CT영상으로부터 인체의 기관지 모델의 개발)

  • Won, Chul-Ho;Ro, Chul-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.263-272
    • /
    • 2002
  • In this paper, we investigate the potential for retrieval of morphometric data from three dimensional images of conducting bronchus obtained by X-ray Computerized Tomography (CT) and to explore the potential for the use of rapid prototype machine to produce physical hollow bronchus casts for mathematical modeling and experimental verification of particle deposition models. We segment the bronchus of lung by mathematical morphology method from obtained images by CT. The surface data representing volumetric bronchus data in three dimensions are converted to STL(streolithography) file and three dimensional solid model is created by using input STL file and rapid prototype machine. Two physical hollow cast models are created from the CT images of bronchial tree phantom and living human bronchus. We evaluate the usefulness of the rapid prototype model of bronchial tree by comparing diameters of the cross sectional area bronchus segments of the original CT images and the rapid prototyping-derived models imaged by X-ray CT.

A Novel Modeling Method for Manufacturing Hearing Aid Using 3D Medical Images (3차원 의료영상을 이용한 보청기 제작의 새로운 모델링 방법)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.257-262
    • /
    • 2016
  • This study aimed to suggest a novel method of modeling a hearing aid ear shell based on Digital Imaging and Communication in Medicine (DICOM) in the hearing aid ear shell manufacturing method using a 3D printer. In the experiment, a 3D external auditory meatus was extracted by using the critical values in the DICOM volume images, and the modeling surface structures were compared in standard type STL (STereoLithography) files which could be recognized by a 3D printer. In this 3D modeling method, a conventional ear model was prepared, and the gaps between adjacent isograms produced by a 3D scanner were filled with 3D surface fragments to express the modeling structure. In this study, the same type of triangular surface structures were prepared by using the DICOM images. The result showed that the modeling surface structure based on the DICOM images provide the same environment that the conventional 3D printers may recognize, eventually enabling to print out the hearing aid ear shell shape.

Comparison of the Quality of Clavicle Fracture Three-dimensional Model Printing by Open Source and Commercial use Digital Imaging and Communications in Medicine Stereolithography File Conversion Program (공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교)

  • Oh, Wang-Kyun;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.61-66
    • /
    • 2018
  • The recent 3D printing technology is used in various medical, manufacturing, and education fields and is more efficient in terms of production process, time, and cost than existing production. Especially in fracture surgery, interest and research have been focused on improving accuracy, shortening of operation time and recovery time, and reducing reoperation. However, because of the financial and technical problems of the 3D printer and the file conversion program, the 3D printing is made directly at the hospital, and it is not generally used for diagnosis of fracture and surgical research. In this study, to solve those problems, clavicle CT imaging was switched into Osirix Open Source DICOM Viewer, Stereolithography file conversion programs and commercial Terarecon 3D DICOM Viewer, file conversion programs, and then clavicle fracture model was directly made through 3D printer of fused filament fabrication wire additive processing method, and then the accuracy of the shape was compared and analyzed. Clavicle fracture models printed in two methods were blind-tested on clinicians of general hospitals' orthopedics and radiologic technicians with over 10 years of experiences, and then their analysis opinions of resolution reviews were analyzed. The result showed no difference. The 3D printing model with open source DICOM STL file conversion program used was applicable to clinical, so it is considered useful in precision diagnosis of fracture and operation plans.