• Title/Summary/Keyword: STC

Search Result 230, Processing Time 0.029 seconds

Temperature Compensation of NDIR $CO_{2}$ Gas Sensor Implemented with ASIC Chip (ASIC 칩 내장형 비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Yi, Seung-Hwan;Park, Jong-Seon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.40-45
    • /
    • 2007
  • This paper describes NDIR $CO_{2}$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor module shows high accuracy ($less\;than {\pm}40\;ppm$) throughout the measuring concentration of $CO_{2}$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than ${\pm}5\;ppm$ error throughout the measuring temperature range ($15^{\circ}C\;to\;35$^{\circ}C$) and gas concentrations with self-temperature compensation.

  • PDF

A study of STB software development for streaming synchronized data processing (스트리밍 동기화 데이터 처리를 위한 단말 소프트웨어 개발에 관한 연구)

  • 신중목;유지상
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.6A
    • /
    • pp.690-696
    • /
    • 2004
  • Advanced Television Systems Committee (ATSC) -A/90, which is a standard for terrestrial data transmission in Korea, defines synchronized data that has a strong timing association with a separate Program Element. It is classified as synchronized streaming data that is carried in packetized elementary stream (PES) packets or a synchronized non-streaming data that shall be carried in digital storage media command and control (DSM-CC) section. In this paper, we study the design and verification of synchronized streaming data processing algorithm based on ATSC -A/90. We designed a parser and a player for the algorithm development. The received PES packet including synchronized streaming data is parsed in the parser. The parsed synchronized streaming data is synchronized and displayed by player. Finally, we ascertained that STB was working properly with MPEG-2 transport stream (TS) containing synchronized streaming data, as the proposed algorithm is implemented on a set-top box.

A study of algorithm for non-streaming synchronized data processing (비스트리밍 동기화 데이터 처리를 위한 알고리즘 연구)

  • Moon, Gwon-Jae;Yoo, Ji-Sang;Bang, Gun;Choi, Jin-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9A
    • /
    • pp.746-753
    • /
    • 2003
  • In this paper, we propose an efficient algorithm for non-streaming synchronized data processing based on ATSC-DASE in terrestrial digital data broadcasting services. Non-streaming synchronized data is encapsulated in DSM-CC sections with PTS(presentation time stamp) values associated with A/V and it is transmitted in a form of MPEG-2 TS(transport stream). At the receiver, the transmitted A/V data are processed by PC based set-top box(STB) in real-time, and the transmitted non-streaming synchronized data is also stored at the STB and is displayed at right time by the proposed algorithm. To verity the proper operation of the proposed algorithm, we make a scenario for non-streaming synchronized data by XML, and finally we are able to display it properly by using declarative application(DA) browser.

Bacillus stearothermophilus 에서 부분 정제한 Cytosine Deaminase 의 특성

  • 장영채;이경형;김성영;조윤래;김종규
    • Korean Journal of Microbiology
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 1992
  • Cytosine deaminase (EC 3.5.4.1) from BaciNus stc~urorhermophilus was partially purified 7.2-fold with an overall yield of 52.7%. The partially purified enzyme deiiminated cytosine only.but not 5-methylcytosine and 5-fluorocytosine. The apparent Michaclis constant. Km valuefor cytosine was 5.9 mM. The enzyme was relatively stable in the range of pH 4.0 to 7.0.furthermore extremely thermo-stable : more than 75'X) of the activity was remained afterheating at 80$^{\circ}$C for I0 min at pH 6.5. The enzyme had a pH optimum at around pH7.0 to 7.5. and temperature optimum at 35 to 31$^{\circ}$C. And the activation energ (En value)determined from an Arrhenius plot was 26 Kcal/mol. The enzyme activity was stronglyinhibited by heavy metal ions such as Cd", Hg". Cut' at 1 mM, anJ by o-phenanthroline,and p-chloromcrcuribcnzoate at I mM. But the enrymc activity was activatetl increased byGMP, and CMP at 1 mM.ased by GMP, and CMP at 1 mM.

  • PDF

Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications (초음파센서를 이용한 변량제어 스프레이어)

  • Jeon, Hong-Young;Zhu, Heping
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

Wake-Induced Boundary Layer Transition on an Airfoil at Moderate Free-Stream Turbulence (자유유동 난류강도에 따른 익형 위 후류유도 경계층 천이의 거동)

  • Park, Tae-Choon;Kang, Shin-Hyoung;Jeon, Woo-Pyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.921-928
    • /
    • 2006
  • Wake-induced boundary-layer transition on a NACA0012 airfoil with zero angle of attack is experimentally investigated in periodically passing wakes under the moderate level of free-stream turbulence. The periodic wakes are generated by rotating circular cylinders clockwise or counterclockwise around the airfoil. The free-stream turbulence is produced by a grid upstream of the rotating cylinder, and its intensities $(Tu_{\infty})$ at the leading edge of the airfoil are 0.5 and 3.5%, respectively. The Reynolds number (Rec) based on chord length (C) of the airfoil is $2.0{\times}10^5$, and Strouhal number (Stc) of the passing wake is about 1.4. Time- and phase-averaged streamwise mean velocities and turbulence fluctuations are measured with a single hot-wire probe, and especially, the corresponding wall skin friction is evaluated using a computational Preston tube method. The patch under the high free-stream turbulence $(Tu_{\infty}=3.5%)$ grows more greatly in laminar-like regions compared with that under the low turbulence $(Tu_{\infty}=0.5%)$ in laminar regions. The former, however, does not greatly change the turbulence level in very near-wall region while the latter does it. At further downstream, the former interacts vigorously with high environmental turbulence inside the pre-existing transitional boundary layer and gradually loses its identification, whereas the latter keeps growing in the laminar boundary layer. The calmed region is more clearly observed under the lower free-stream turbulence level and with the receding wakes.

Studies on the functional properties of sugar derivative sweeteners (당유도체 감미료의 식품기능성에 관한 연구)

  • Lee, Cherl-Ho;Souane, Moussa;Lee, Hyun-Duck;Kim, Sun-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.5 no.4
    • /
    • pp.431-436
    • /
    • 1990
  • The functional properties of novel sugar derivative sweeteners, fructo-oligosaccharide, maltitol, sorbitol and high maltose syrup(HMS) were examined for their humactant effect, lactic acid bacterial growth, Streptococcus mutants growth and relative sweetness compared to sucrose. Sorbitol exhibited remarkably high water activity reducing capacity, whereas fructo-oligosaccharide and maltitol showed the same level as sucrose. Maltitol showed distinct anti-bacterial(bacteriocidic) effect against Stc. mutants and most of lactic acid bacteria tested except for L. plantarum. The molar basis relative sweetness of sugar derivatives in comparison with 1%(w/w) level of sucrose were 0.69 for Neosugar(fructo-oligosaccharide), 0.21 for sorbitol, 0.50 for maltitol and 0.27 for HMS.

  • PDF

Object tracking based on adaptive updating of a spatial-temporal context model

  • Feng, Wanli;Cen, Yigang;Zeng, Xianyou;Li, Zhetao;Zeng, Ming;Voronin, Viacheslav
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5459-5473
    • /
    • 2017
  • Recently, a tracking algorithm called the spatial-temporal context model has been proposed to locate a target by using the contextual information around the target. This model has achieved excellent results when the target undergoes slight occlusion and appearance changes. However, the target location in the current frame is based on the location in the previous frame, which will lead to failure in the presence of fast motion because of the lack of a prediction mechanism. In addition, the spatial context model is updated frame by frame, which will undoubtedly result in drift once the target is occluded continuously. This paper proposes two improvements to solve the above two problems: First, four possible positions of the target in the current frame are predicted based on the displacement between the previous two frames, and then, we calculate four confidence maps at these four positions; the target position is located at the position that corresponds to the maximum value. Second, we propose a target reliability criterion and design an adaptive threshold to regulate the updating speed of the model. Specifically, we stop updating the model when the reliability is lower than the threshold. Experimental results show that the proposed algorithm achieves better tracking results than traditional STC and other algorithms.

Analysis of Sound Insulation Performance of Honeycomb Composite Panels for Cruise Ships (크루즈선박용 허니컴 패널의 차음 성능 해석)

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Roh, Jae-Ouk;Song, Jee-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.234-240
    • /
    • 2014
  • In this paper, the interface matrix of honeycomb composite panel has been derived by the governing equation of a honeycomb sandwich panel. The interface matrix of honeycomb panel is added to the previously developed transfer matrix method, thus analysis of the multi-layered insulation composite panel with honeycomb is accomplished. Furthermore, predictions of sound transmission loss(STL) for the ship's insulation panel with honeycomb and mineral wool are presented. The insulation performance of the honeycomb used for skin of the ship's insulation panel is better than that of 0.35 mm steel panel by 2dB, approximately. Although honeycomb panel has inefficient insulation performance beside steel panel, honeycomb panel achieve improvements in the performance of weight reduction. The surface density of the panel with honeycomb is rather than with steel by $5.2kg/m^2$. It is decrease in weight by 31.7 %.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.