• 제목/요약/키워드: STATIC-99

검색결과 172건 처리시간 0.025초

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

청주시 한방난임지원사업에 참여한 난임환자의 한의학적 변증 특성 연구 (A Study on Pattern Identification of Patients Who Participated in Korean Medical Infertility Support Program of CheongJu-City)

  • 권나연;박용연;김형준;이동녕
    • 대한한방부인과학회지
    • /
    • 제31권4호
    • /
    • pp.147-164
    • /
    • 2018
  • Objectives: This study was performed to analyze the pattern identification in infertile women who participated in infertility support program of Cheongju-city. Methods: The project proceeded from October, 2016 to June 2017. Participants filled in the questionnaire which is composed of 33 symptoms before korean medical treatments. Data were collected from 17 participants. We classified symptoms into six pattern identifications based on previous research and rated each answer to score. Results: Throughout the study, the average age of 26 patients was $34.88{\pm}3.19$ years old, the average height was $162.51{\pm}4.99cm$, and average weight was $58.41{\pm}7.88kg$. The average duration of acupuncture treatment was $121.03{\pm}52.73$ days and the average times of acupuncture treatment was $27.42{\pm}10.77$ times. The average number of herbal medicine treatment was $2.65{\pm}0.69$, the majority of it was Chokyungjongok-tang. After the treatment, 3 patients of infertility became pregnant (11.54%) in twenty six patients. By analyzing pattern identification survey papers, We can classify infertile women into 6 pattern identification based on previous research. The majority of participants was identified as Blood deficiency and the other participants were identified as Kidney deficiency, Liver depression, Dampness-phlegm, Qi deficiency and Static blood in order of priority. Most of patients' pattern identification were combined with two kind of pattern identification. In terms of priority, Liver depression combined with Kidney deficiency, Blood deficiency combined with Kidney deficiency, Liver depression combined with Qi deficiency, Liver depression combined with Dampness-phlegm. Conclusions: After the study we confirmed that Korean traditional medicine is a safe treatment for infertile women. Further clinical study about herbal medicines of patients who have combined pattern identification is needed.

개선된 인양홀을 이용한 정착장치로 보강된 RC 보의 거동 (Behavior of RC Beam Strengthened with Advanced Lifting Hole Anchorage System)

  • 오민호;김태완;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.91-99
    • /
    • 2010
  • RC 구조물의 보강에는 여러 가지 보강공법이 사용되고 있으며 특히 외부강선 보강공법은 손상된 구조물을 보강하는 대표적인 공법이며 효율성, 용이성, 경제성의 면에서도 우수하다. 본 연구에서는 PSC 및 RC 거더에서 추가 손상 없이 충분한 보강효과를 얻을 수 있는 보강공법으로써 개선된 인양홀을 이용한 정착장치를 제안하였다. 2가지 유형의 새롭게 제안된 정착장치를 6개의 실험체의 적용하였고 기존의 정착장치를 3개의 실험체에 적용하였다. 한 개의 실험체는 보강효율을 판단하기 위하여 보강공법을 적용하지 않았다. 이들 정착장치의 거동을 분석하기 위하여 정적 재하 시험을 수행하였고 실험변수들은 정착장치의 형상, 강봉의 긴장정도와 강선의 설치형태이다. 각 실험체의 보강 효과를 조사하기 위해 처짐, 변형률 그리고 파괴양상을 기록하였으며 균열하중, 항복하중, 극한하중, 연성지수 그리고 강선의 응력을 분석하였다. 그 결과 제안된 인양홀을 이용한 정착장치는 기존의 정착장치보다 높은 보강효율을 보였으며, 에너지 개념을 이용한 연성도 평가에 따르면 충분한 연성을 확보하고 있음을 알 수 있었다.

Study of seismic performance of super long-span partially earth-anchored cable-stayed bridges

  • Zhang, Xin-Jun;Yu, Cong;Zhao, Jun-Jie
    • Structural Engineering and Mechanics
    • /
    • 제72권1호
    • /
    • pp.99-111
    • /
    • 2019
  • To investigate the seismic performance of long-span partially earth-anchored cable-stayed bridge, a super long-span partially earth-anchored cable-stayed bridge scheme with main span of 1400m is taken as example, structural response of the bridge under E1 seismic action is investigated numerically by the multimode seismic response spectrum and time-history analysis, seismic behavior and also the effect of structural geometric nonlinearity on the seismic responses of super long-span partially earth-anchored cable-stayed bridges are revealed. The seismic responses are also compared to those of a fully self-anchored cable-stayed bridge with the same main span. The effects of structural parameters including the earth-anchored girder length, the girder width, the girder depth, the tower height to span ratio, the inclination of earth-anchored cables, the installation of auxiliary piers in the side spans and the connection between tower and girder on the seismic responses of partially ground-anchored cable-stayed bridges are investigated, and their reasonable values are also discussed in combination with static performance and structural stability. The results show that the horizontal seismic excitation produces significant seismic responses of the girder and tower, the seismic responses of the towers are greater than those of the girder, and thus the tower becomes the key structural member of seismic design, and more attentions should be paid to seismic design of these sections including the tower bottom, the tower and girder at the junction of tower and girder, the girder at the auxiliary piers in side spans; structural geometric nonlinearity has significant influence on the seismic responses of the bridge, and thus the nonlinear time history analysis is proposed to predict the seismic responses of super long-span partially earth-anchored cable-stayed bridges; as compared to the fully self-anchored cable-stayed bridge with the same main span, several stay cables in the side spans are changed to be earth-anchored, structural stiffness and natural frequency are both increased, the seismic responses of the towers and the longitudinal displacement of the girder are significantly reduced, structural seismic performance is improved, and therefore the partially earth-anchored cable-stayed bridge provides an ideal structural solution for super long-span cable-stayed bridges with kilometer-scale main span; under the case that the ratio of earth-anchored girder length to span is about 0.3, the wider and higher girder is employed, the tower height-to-span ratio is about 0.2, the larger inclination is set for the earth-anchored cables, 1 to 2 auxiliary piers are installed in each of the side spans and the fully floating system is employed, better overall structural performance is achieved for long-span partially earth-anchored cable-stayed bridges.

전극의 부반응 기포발생에 따른 휘발특성과 전기화학고도산화능을 동시에 고려한 휘발성 유기화합물 처리용 최적 불용성전극 개발 (Optimum dimensionally stable anode with volatilization and electrochemical advanced oxidation for volatile organic compounds treatment)

  • 조완철;부경민;이지은;김태남;채규정
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.31-41
    • /
    • 2019
  • Volatile organic compounds(VOCs) are toxic carcinogenic compounds found in wastewater. VOCs require rapid removal because they are easily volatilized during wastewater treatment. Electrochemical advanced oxidation processes(EAOPs) are considered efficient for VOC removal, based on their fast and versatile anodic electrochemical oxidation of pollutants. Many studies have reported the efficiency of removal of various types of pollutants using different anodes, but few studies have examined volatilization of VOCs during EAOPs. This study examined the removal efficiency for VOCs (chloroform, benzene, trichloroethylene and toluene) by oxidization and volatilization under a static stirred, aerated condition and an EAOP to compare the volatility of each compound. The removal efficiency of the optimum anode was determined by comparing the smallest volatilization ratio and the largest oxidization ratio for four different dimensionally stable anodes(DSA): Pt/Ti, $IrO_2/Ti$, $IrO_2/Ti$, and $IrO_2-Ru-Pd/Ti$. EAOP was operated under same current density ($25mA/cm^2$) and electrolyte concentration (0.05 M, as NaCl). The high volatility of the VOCs resulted in removal of more than 90% within 30 min under aerated conditions. For EAOP, the $IrO_2-Ru/Ti$ anode exhibited the highest VOC removal efficiency, at over 98% in 1 h, and the lowest VOC volatilization (less than 5%). Chloroform was the most recalcitrant VOC due to its high volatility and chemical stability, but it was oxidized 99.2% by $IrO_2-Ru/Ti$, 90.2% by $IrO_2-Ru-Pd/Ti$, 78% by $IrO_2/Ti$, and 75.4% by Pt/Ti anodes The oxidation and volatilization ratios of the VOCs indicate that the $IrO_2-Ru/Ti$ anode has superior electrochemical properties for VOC treatment due to its rapid oxidation process and its prevention of bubbling and volatilization of VOCs.

옥수수 재배지 아산화질소 배출에 대한 질소비료와 바이오차 시용 효과 (Effect of Biochar Application on Nitrous Oxide Emission in the Soil with Different Types of Nitrogen Fertilizer During Corn (Zea may) Cultivation)

  • 이선일;김건엽;최은정;이종식;권효숙;신중두
    • 한국환경농학회지
    • /
    • 제39권4호
    • /
    • pp.297-304
    • /
    • 2020
  • BACKGROUND: Emission of nitrous oxide (N2O) from the soil is expected to depend on the types of nitrogen fertilizer used. Biochar has recently been proposed as a potential mitigation of climate change by reducing the N2O emission. Although laboratory studies reported that biochar applications could reduce N2O emission, the number of field-based studies is still limited. Therefore, a field experiment was conducted to investigate the effect of biochar on N2O emission when different nitrogen fertilizers were applied in corn cultivated field. METHODS AND RESULTS: The field experiment consisted of six treatments: urea fertilizer without biochar (U), ammonium sulfate fertilizer without biochar (A), oil cake fertilizer without biochar (O), urea fertilizer with biochar (U+B), ammonium sulfate fertilizer with biochar (A+B), and oil cake fertilizer with biochar (O+B). Biochar was applied at a rate of 10 t/ha. Greenhouse gas fluxes were measured during growing seasons using static vented chambers. The cumulative N2O emissions were 0.99 kg/ha in the U, 1.23 kg/ha in the A, 3.25 kg/ha in the O, 1.19 kg/ha in the U+B, 0.86 kg/ha in the A+B, and 1.55 kg/ha in the O+B. CONCLUSION: It was found that N2O emission was related to application of both nitrogen fertilizer type and biochar. In particular, the N2O reduction effect was the highest in the corn field incorporated with biochar when oil cake was applied to the soil.

서버 클러스터 환경에서 자율학습기반의 에너지 효율적인 클러스터 관리 기법 (An Energy Efficient Cluster Management Method based on Autonomous Learning in a Server Cluster Environment)

  • 조성철;곽후근;정규식
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제4권6호
    • /
    • pp.185-196
    • /
    • 2015
  • 에너지 절감형 서버 클러스터는 에너지 절감을 고려하지 않는 기존 서버 클러스터에 비해 서비스 품질을 보장하면서 전력소비를 절감하는 것을 목표로 한다. 에너지 절감형 서버 클러스터에서는 현재의 부하를 처리하는 데 필요한 최소수의 서버들만 ON 하도록 고정 또는 가변 주기로 서버들의 전원모드를 조정한다. 이에 대한 기존 연구들은 전력 절감 또는 서비스 품질을 보장하려고 노력해왔지만 에너지 효율성을 잘 고려하지는 못했다. 본 논문에서는 에너지 절감형 클러스터에서 자율학습기반의 에너지 효율적인 클러스터 관리 기법을 제안한다. 자율학습을 통해 최적화된 파라미터들을 이용하여 전력 소모 대비 최고의 성능을 얻을 수 있도록 서버 전원모드를 조정한다. 제안방법은 서버 전원모드 조정을 위해 아래의 과정을 반복 수행한다. 첫째, 현재 부하 및 트래픽 패턴을 보고 현재 워크로드 패턴 유형을 사전에 정의한 대로 분류한다. 둘째, 학습 테이블을 탐색하여 해당 워크로드 패턴 유형에 대해 예전에 학습이 수행되었는지 확인한다. 만일 수행되었다면 이미 저장된 파라미터를 이용한다. 그렇지 않으면, 학습을 수행하여 에너지 효율성 관점에서 최고의 파라미터를 얻어 저장한다. 셋째, 얻어진 파라미터를 이용하여 서버 전원모드를 조정한다. 제안방법을 구현하여 16개의 서버 클러스터 환경에서 3가지 다른 부하 패턴들을 이용하여 실험을 수행하였다. 실험 결과는 제안방법의 에너지 효율성이 뛰어남을 보여주고 있다. 뱅킹 부하패턴, 실제 부하패턴, 가상 부하패턴 각각에 대하여, 제안방법의 단위전력당 good 응답 수가 기존의 정적 서버 전원모드 제어방법의 99.9%, 107.5%, 141.8%이고, 기존의 예측방법의 102.0%, 107.0%, 106.8%이다.

위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성 (The Usefulness of Scintigraphy for the Detection of Gastroesophageal Reflux and Pulmonary Aspiration)

  • 강성길;현인영;임대현;김정희;손병관
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제11권1호
    • /
    • pp.12-20
    • /
    • 2008
  • 목 적: 영유아에서 위식도 역류는 흔한 질환이며, 위식도 역류의 합병증으로 위 내용물의 폐 흡인에 의한 만성 호흡기 질환이 생길 수 있으나 이를 진단하기 위한 표준적인 검사 방법이 없다. 본 연구에서는 위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성을 평가하고자 하였다. 방 법: 위식도 역류로 인한 흡인 폐렴이 의심된 35명의 환아와 정상 대조군 5명을 대상으로 하였다. 모든 대상아에게 $^{99m}Tc$-tin colloid를 첨가한 우유를 수유한 후 위식도 역류 신티그래피를 시행하였다. 위식도 역류를 진단하기 위해 1시간 동안 동적 영상을 촬영하였고, 폐 흡인을 진단하기 위해 6시간과 24시간 후 지연 영상으로 정적 영상을 얻었다. 폐 흡인의 진단을 위해 육안분석과 함께 양쪽 폐에 관심 영역을 설정하여 정량 분석을 시행하였다. 흡인 지수는 관심 영역에서 배경 영역의 계수치를 뺀 값으로 정의하였다. 결 과: 35명의 환아 중 23명에서 신티그래피상 위식도 역류가 관찰되었고, 정상 대조군 5명에서는 위식도 역류가 발견되지 않았다. 환아군 35명 중 24명에게 24시간 하부 식도 pH 검사를 시행하였고, 7명에서 산성역류가 확인되었다. 신티그래피와 하부 식도 pH 검사를 동시에 받은 24명 중 8명에서 두 검사의 결과가 일치하여 두 검사는 위식도 역류의 진단에 있어 일치하지 않았다. 환아군 35명 중 16명에게 흉부 전산화 단층 촬영을 시행하여 13명의 환아에서 의존성 위치에 폐 경화가 발견되어 흡인 폐렴으로 진단하였고, 이 환아들이 신티그래피에서도 폐 흡인이 있었는지 그 일치도를 알아보았을 때, 두 검사는 폐 흡인의 진단에 있어 일치하지 않았다. 한 명의 환아에서 6시간 후 지연 영상에 우폐로 역류된 방사능이 육안적으로 관찰되었다. 대조군과 비교하였을 때, 30명(85.7%)의 환아에서 흡인 지수가 결정점인 0.3보다 높아 폐 흡인의 가능성이 높은 것으로 진단하였다. 역류군과 비 역류군을 비교하였을 때, 6시간 후 지연 영상에서 흡인 지수는 역류군에서 유의하게 높았다(p<0.05). 결 론: 위식도 역류 신티그래피는 비 침습적이고 안전한 검사로 위식도 역류의 진단에 있어서는 24시간 하부 식도 pH 검사에 비하여 부족하지만 역류로 인한 소량의 폐 흡인을 진단하는데 유용하며, 앞으로 통계학적으로 의미 있는 수의 대조군 연구가 수행된다면 폐 흡인을 확진할 수 있는 진단 기준이 나올 것으로 생각된다.

  • PDF

동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교 (Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System)

  • 강천구;박훈희;오신현;이한울;김정열;오주영;이주영;김재삼;이창호
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.3-9
    • /
    • 2013
  • 핵의학 검사 중 동적 신장검사는 신장기능을 평가하는 가장 대표적인 검사법으로 방사성동위원소를 이용하여 시간에 따른 신장의 기능을 평가하고 소변이 배설에 이르기까지의 질환 평가에 유용하다. 이러한 검사영상의 질 평가 및 정량 분석에서 현재 상용화 된 팬텀은 정적 상황만 재현하고 평가할 수 있기 때문에 동적 팬텀을 통한 시간에 따른 신장의 기능적 상황과 혈류속도, 방사성동위원소의 주입량에 따른 다양한 차이 등을 확인할 수 있는 연구가 미비한 상황이다. 그러므로 본 연구를 통해 동적 신장팬텀 시스템을 제작하여 신장의 동적 흐름을 통한 영상을 재현함으로써 핵의학에서 영상학적으로 유용성을 평가하고자 한다. 신장팬텀은 정상 성인 신장을 기준으로 제작하였고, 동적 상황을 재현하기 위하여 혈류의 속도를 조절할 수 있는 정량 펌프를 적용하였으며, $^{99m}Tc-pertechnate$를 신장팬텀에 방사성의약품이 집적되고 방광으로 배설되도록 제작하였다. 사용된 방사성의약품은 각 신장팬텀에 각각 주입되도록 하였으며, 주입속도, 방사성의약품, 좌우 신장팬텀에 다른 주입속도에 따른 변화를 확인하였다. 획득한 영상의 분석은 전면상과 후면상 각각의 신장과 방광에 관심영역을 그려 분석하였으며, 재현성을 확인하기 위하여 각 10회씩 반복하여 분석하였다. 동일한 조건하에 주입속도 40 mL/min로 고정하여 펌프의 압력을 조절하였을 때 방사성의약품이 2-3분 사이에 신장팬텀에 가장 많이 집적되었다가 방광으로 배출되었다. 각 장비별 사구체 여과율은 각각 SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min로 통계적으로 유의한 차이가 있는 것으로 나타났으며, Tmax 값 그리고 T1/2 값 모두에서 장비별 통계적으로 유의한 차이가 있는 것으로 나타났다. 변동계수인 CV 값은 5% 이하로 재현성이 있는 것으로 나타났으며, 그 중에서 SYMBIA가 2.67%로 가장 낮게 나타났고, INFINIA가 4.86%으로 가장 높게 나타났다. 본 연구를 통하여 동적신장팬텀시스템이 실제 임상의 신장동적검사를 유사하게 재현이 가능한 것을 확인할 수 있었다. 특히 신장을 통해 방광으로 배설되는 흐름에 대해 시간에 따른 묘사가 충분하게 재현되었으며, 동적 영상의 질을 확인하는데 기초 자료로 활용이 가능하리라 사료된다. 또한 추후 기능적 영상 분야에 연구 및 정도관리 분야에도 도움이 되리라 여겨진다.

  • PDF

핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가 (Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine)

  • 박훈희;이주영;김상욱;유광열;진계환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.49-55
    • /
    • 2013
  • 핵의학 검사 중 동적신장검사는 신장기능을 평가하는 가장 대표적인 검사법으로 방사성의약품을 이용하여 시간에 따른 신장의 기능을 평가하고 소변이 배설에 이르기까지의 질환 평가에 유용하다. 이러한 검사영상의 질 평가 및 정량분석에서 현재 상용화 된 팬텀은 정적 상황만 재현하고 평가할 수 있기 때문에 동적 팬텀을 통한 시간에 따른 신장의 기능적 상황과 혈류속도, 방사성의약품의 주입량에 따른 다양한 차이 등을 확인 할 수 있는 연구가 미비한 상황이다. 그러므로 본 연구를 통해 동적 신장팬텀시스템을 제작하여 신장의 동적 흐름을 통한 영상을 재현함으로써 핵의학에서 영상학적으로 유용성을 평가하고자 한다. 신장팬텀은 정상 성인 신장을 기준으로 제작하였고, 동적 상황을 재현하기 위하여 혈류의 속도를 조절할 수 있는 정량펌프를 적용하였으며, $^{99m}Tc$-pertechnate를 신장팬텀에 방사성의약품이 집적되고 방광으로 배설되도록 제작하였다. 사용된 방사성의약품은 각 신장팬텀에 각각 주입되도록 하였으며, 주입속도, 방사성의약품, 좌우 신장 팬텀에 다른 주입속도에 따른 변화를 확인하였다. 획득한 영상의 분석은 전면상과 후면상 각각의 신장과 방광에 관심영역을 그려 분석하였으며, 재현성을 확인하기 위하여 각 5회씩 반복하여 분석하였다. 주입속도 변화에 대해 30 stroke으로 펌프의 압력을 조절하였을 때 방사성의약품이 신장팬텀에 가장 많이 집적되었다가 배출되었고, 40 stroke으로 조절하였을 때 가장 적게 집적되었다가 배출되었다. 10 stroke으로 조절한 경우 좌우신장의 집적량이 최고치에 도달하지 못하였다. 방사성동위원소의 양에 따른 변화에서는 0.6 mCi (22.2 MBq), 0.8 mCi (29.6 MBq) 모두 유사한 성향을 나타냈으나, 0.8 mCi 를 주입한 결과에서는 0.6 mCi의 두배에 가까운 수치(count)를 나타냈다. 좌측신장모형은 20 stroke, 우측신장모형은 30 stroke으로 다른 조건으로 시행한 결과, 최고점에 이른 시간이 각각 다르게 형성되었으며, 이는 결과 영상에서도 육안으로 쉽게 구분할 수 있었다. 본 연구를 통하여 동적 신장팬텀시스템이 실제 임상의 동적 신장검사를 유사하게 재현이 가능한 것을 확인할 수 있었다. 특히 신장을 통해 방광으로 배설되는 흐름에 대해 시간에 따른 묘사가 충분하게 재현되었으며, 동적 영상의 질을 확인하는데 기초 자료로 활용이 가능하리라 사료된다. 또한 추후 기능적 영상 분야에 연구 및 정도관리 분야에도 도움이 되리라 여겨진다.