• 제목/요약/키워드: STAR-CD

검색결과 141건 처리시간 0.027초

디젤엔진의 공기청정기내 압력 및 유동분포에 관한 연구 (Study of Pressure and Flow in the Air-Cleaner of Commercial Vehicle)

  • 류명석;구영곤;김경훈;맹주성
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.47-53
    • /
    • 1997
  • The importance of intake system can not be overstressed in the recent heavy duty commercial vehicle design. The basic requirements of intake system are to have less flow resistance and better air cleaning performance which have direct effects on the performance and service life of engine. In order to improve the performance of engine intake system, the flow phenomena in the intake system should be fully understood. With readily availble CFD code, the numerical analysis becomes the more reliable tools for flow optimization in recent design work. In this research, flow field in the intake system was analyzed by STAR-CD, the 3-D computational fluid dynamics code. Especially, the flow inside of air cleaner was thoroughly analyzed. Pressure distribution and velocity profile in the air cleaner and intake duct was obtained. Having the dust seperated from incoming air at the expense of less pressure drop is the ultimate goal for the research.

  • PDF

소형버스 냉각성능 향상 연구(I) (Study for the Cooling Performance Improvement of a Mini Bus)

  • 류명석
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.10-15
    • /
    • 2005
  • This study was initiated to evaluate the cooling performance of CAC (charged air cooler) and radiator in the engine room of a mini bus. So we had firstly to predict the mass flow rate coming from radiator grille and front bum per opening using computational fluid dynamics (CFD) simulation based on 3D configuration. And simulations were carried out for different cooling module layout and bum per opening hole size on sam e vehicle operating condition. Simulation results show that CAC cooling performance at reverse protecting plate-applying model was much efficient than that of the bum per opening hole size-increasing model in IMTD point of view. Part of the CFD simulation results was com pared to with experimental data. It was confirm ed that the CFD approach using STAR-CD based on pursuing no-com promise solution could provide design engineers with useful design information in the early design stage of vehicle development.

대형버스 흡기시스템 성능 개선에 관한 연구 (A Study on the Performance Improvement in the Intake System of a Large-sized Commercial Bus)

  • 류명석
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2005
  • The performance of reciprocating internal combustion engine is a strong function of the air intake system configuration. In order to improve engine power, it is essential to optimize the air induction system. In this study, a numerical investigation has been carried out for the three-dimensional flow and pressure characteristics in air intake system of a large-sized commercial bus. CFD simulations using STAR-CD were also perform ed to evaluate effects of intake duct geometry and structure variation inside air cleaner on the negative pressure distribution of overall intake system. Studies for improving the back pressure distribution have been proposed and quantitatively examined based on intensive case studies.

Aerodynamic performance enhancement of cycloidal rotor according to blade pivot point movement and preset angle adjustment

  • Hwang, In-Seong;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제9권2호
    • /
    • pp.58-63
    • /
    • 2008
  • This paper describes aerodynamic performance enhancement of cycloidal rotor according to the blade pivot point movement and the blade preset angle adjustment. Cycloidal blade system which consists of several blades rotating about an axis in parallel direction and changing its pitch angle periodically, is a propulsion mechanism of a new concept vertical take off and landing aircraft, cyclocopter. Based on the designed geometry of cyclocopter, numerical analysis was carried out by a general purpose commercial CFD program, STAR-CD. According to tills analysis, the efficiency of cycloidal rotor could be improved more than 15% by the introduced methods.

5ESS-2000 통신장비실의 열환경특성과에너지성능 개선방안에 관한 연구 (A Study on the Characteristics of Thermal Environment and Improvement of Energy Performance in 5ESS-2000 Telecommunication Equipment Room)

  • 이승복;조춘식
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.19-26
    • /
    • 2004
  • The purpose of this study was to evaluate the thermal environment of present state and energy consumption and to verify the improvement of energy performance applying free cooling in 5ESS-2000 telecommunication equipment room. Analysis program is used the DOE-2.1E and commercial CFD code, Star-CD. The results of the simulation show that free cooling could reduce 42.1% of cooling energy, increase 48.5% of heating energy because introduced outdoor air must heating and humidification. Therefore free cooling could reduce yearly 34,609.9 kWh of heating and cooling energy and this is reaching to 21.6% of total energy.

원심형 홴의 유동해석에 관한 연구 (Flow Field Analysis of a Centrifugal Fan)

  • 신동신;임종수;김창성;노오현;이수갑
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.43-49
    • /
    • 1999
  • Flow field and near-field noise of a centrifugal fan has been studied with an efficient compressible method and STAR-CD. The flow field of the centrifugal fan is assumed to be two-dimensional. Most of the compressible studies have been done by inviscid solver because viscous simulation shows little difference. The near field noise is estimated in terms of sound pressure level in frequency domain transformed from the computed pressure fluctuations using FFT. The simulation has been done on various design elements such as impeller blade shapes, the number of blades and cut-off clearance. The comparison shows that the number of blades has a significant effect on near-field noise without losing aerodynamic performance.

  • PDF

Computational Analysis of the Three-Dimensional Flow Fields of Sirocco Fan

  • Hah, Jae-Hong;Moon, Young-J.;Park, Jin-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.44-50
    • /
    • 2001
  • The Sirocco fan performance and its three-dimensional flow characteristics are numerically prediction by STAR-CD. Turbulent flow computations are performed using approximately 500,000 mesh points, and the performance results of tow computational methods, transient and quasi-static flow analyses are compared with experimental data. In the present study, our attention is focused on the three-dimensional flow characteristics of the Sirocco fan blades and the secondary flow structure in the scroll. For a design optimization study, the scroll shape is titled by $10^\circ$ to modify the secondary flow structure, which yields some improvement of the fan performance.

  • PDF

다양한 형태의 버너를 이용한 수증기개질기의 고효율화 연구 (A Study on the High Efficient Steam Reformer using Various Burner Types)

  • 이명용;이지홍;이상석;이진석;이도형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2886-2891
    • /
    • 2008
  • The purpose of this study is to develop a highly-efficient and compact steam reformer for PEMFC changing the burner types. For the purpose some of the Can type flat burners were adopted and the results were compared with 'O' company's typical cylinderical flat burner. We used commercial STAR-CD tools for numerical calculation. We found the optimum Can type STR burner and this type of burner was highly efficient comparing with typical burner.

  • PDF

디젤 엔진의 분사각 변화가 배기가스에 미치는 영향에 관한 수치해석적 연구 (A Numerical Study on Effect of Variation of Injection Angle on the Emissions)

  • 배명직;이병화;한동식;전충환;장영준;송주헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3085-3089
    • /
    • 2008
  • In order to reduce NOx and Soot emissions simultaneously, characteristics of diesel spray and combustion were investigated by numerical simulation with StarCD in this paper. This work focuses on effect of Spin Injection. A simulation model of combustion, spray and emissions is developed for heavy duty marine diesel engine application. Simulation is performed with change of spray angle between first and second directions at fixed engine speed, injection timing, injection duration and etc. The results show that Spin Spray Injection method can reduce NOx emission. And the results show that the 1st injection considerably interfere with 2nd injection characteristics.

  • PDF

두 개의 분지관을 가진 직사각형 덕트 내의 유량배분에 관한 실험 및 수치계산 연구 (Experimental and Computational Studies for Flow Distribution In a Rectangular Duct System with Two Branches)

  • 윤영환;배택희;박원구
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.766-773
    • /
    • 2002
  • Flow distributions in a rectangular duct with two branch ducts are measured by 5 W laser doppler velocity meter. The fluid flows are also computed by commercial soft-ware of STAR-CD for comparison between them. The Reynolds numbers in the main duct are from 4,226 to 17,491. The ratios distributed into two branches from the main duct are in-variant to Reynolds numbers according to both of numerical and experimental results. However computed velocity profiles at exit of each branch are somewhat different from measured profiles at the same location.