• Title/Summary/Keyword: STANDING UP

Search Result 452, Processing Time 0.148 seconds

A Study on the Usability Test of People with Disabilities According to the Development of Powered Wheelchair of Standing Support Type (기립보조형 전동휠체어 개발에 따른 장애인 사용성 평가 연구)

  • Rhee, Kun-Min;Kim, Dong-Ok;Hwangbo, Chi-Wook
    • 재활복지
    • /
    • v.20 no.1
    • /
    • pp.211-233
    • /
    • 2016
  • The purpose of this study is to figure out problems and to suggest improvement scheme by examining 31 of the disabled who used power wheelchair developed for safe moving and standing support. The results are as follows. First, standing power wheelchair that enables the disabled to sit and stand up was developed. It can also be used as means of transportation for moving in narrow space and in a short distance. In the usability test of this prototype, two groups were respectively examined in 60 evaluation items. One group consisted of 16 people with disabilities using manual wheelchairs. And the other one consisted of 15 people with disabilities using automatic wheelchairs. The entire average figure of two groups was shown to be 2.72 and standard deviation was 0.820. Specifically, the average figure of the group in manual wheelchair was 2.85 and the one of the other group in automatic wheelchair was 2.57. And both group replied that the move to stand up and sit on both types of wheelchair was the most inconvenient thing. It shows why ergonomic design for persons with under extremity disabilities to stand up and sit is needed. Second, with further study based on the results of usability test of the disabled, it will make contribution to increase the quality of people with disabilities by helping them move and do daily lives on their own.

Movement Analysis of Elderly People during Ingress/Egress from Different Seat Heights

  • Kim, Yong-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.605-611
    • /
    • 2011
  • Objective: The aim of this study was to investigate the influence of seat heights for optimizing the ingress/egress performance in the elderly people. Background: Recently elderly users have been increasing in number and the ease of ingress/egress of the vehicle becomes an important issue. Method: Seven elderly subjects participated in this study(age: 71.7${\pm}$3.6yr, height: 167.7${\pm}$5.4cm, weight: 68.1${\pm}$11.5kg). Each subject performed the sitting and rising task from comfortable seated position on the chair under the following conditions: (1) with a lumbar support and (2) without a lumbar support. We measured EMG activities of seven muscles(tibialis anterior, soleus, gastrocnemius, vastus lateralis, rectus femoris, biceps femoris and erector supinae) and ranges of motion in lower limb during sitting and standing from three different heights (400mm, 500mm and 600mm from ground) of slide-up seat. Results: Muscle activities and angular movements of hip and knee joints during standing-up and sitting-down with a high seat height(600mm) were reduced mean 30.4% in extensor muscles, 57.11% in flexor muscle, 18.74% in erector muscle and 31.0% in joints compared with a low seat height(400mm). Conclusion: Muscle activities and joint movements in hip and knee were reduced when rising/sitting from a high seat height(600mm) compared with a low seat height(400mm). Application: This study can be used to design vehicle that are easy to get in and out of by older peoples with or without impairments.

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger (스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구)

  • Lee, Sanghoon;Choe, Yongseok;An, Kunmuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

A Study on the Doctrine of Standing in the Suits caused by the Press Reports (언론소송에 나타난 보도의 개별적 연관성과 당사자적격)

  • Lee, Seung-Sun
    • Korean journal of communication and information
    • /
    • v.34
    • /
    • pp.161-195
    • /
    • 2006
  • Standing to sue has become one of the most important and controversial issues in suits between the press and the victims injured by the press reports. Even thought Korean law was patterned after the European legal system, there is no denying that the Korean Constitution was influenced by that of the United States. The judicial system was also influenced by its counterpart in the United States. The doctrine of standing to sue has plagued the U.S. Supreme Court for several decades. The traditional test of standing in the federal courts was, at the beginning of the century, whether the interest asserted by the plaintiff amounted to a 'legal right', entitled to the protection of the common law. In recent years, the Supreme Court seems to have settled on a two-tiered method for determining whether a plaintiff has standing to sue in federal court. The first level of inquiry is the constitutional core, and the second is the judicially imposed prudential limitations. The purpose of this study is to find out the doctrine of standing in the legal proceedings caused by the press reports. The press needs to internally transform as well to prevent legal dispute, enforcing confirmation when collecting news materials and building up the device for pre-examining the news. The press is also requested to help sincerely the victim recover, realizing that they waste their reputation and credit not to mention a lot of time and monet during the legal dispute.

  • PDF

Development of a Machine-Learning based Human Activity Recognition System including Eastern-Asian Specific Activities

  • Jeong, Seungmin;Choi, Cheolwoo;Oh, Dongik
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.127-135
    • /
    • 2020
  • The purpose of this study is to develop a human activity recognition (HAR) system, which distinguishes 13 activities, including five activities commonly dealt with in conventional HAR researches and eight activities from the Eastern-Asian culture. The eight special activities include floor-sitting/standing, chair-sitting/standing, floor-lying/up, and bed-lying/up. We used a 3-axis accelerometer sensor on the wrist for data collection and designed a machine learning model for the activity classification. Data clustering through preprocessing and feature extraction/reduction is performed. We then tested six machine learning algorithms for recognition accuracy comparison. As a result, we have achieved an average accuracy of 99.7% for the 13 activities. This result is far better than the average accuracy of current HAR researches based on a smartwatch (89.4%). The superiority of the HAR system developed in this study is proven because we have achieved 98.7% accuracy with publically available 'pamap2' dataset of 12 activities, whose conventionally met the best accuracy is 96.6%.

The Effect of Dynamic Characteristics of Knitted Fabrics on the Clothing Pressure of Foundation Wear (화운데이션 소재의 역학적 특성이 의복압에 미치는 영향)

  • Jung, Meung-Sun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.11 no.1
    • /
    • pp.79-93
    • /
    • 2002
  • The purpose of this study was to determine the effect of dynamic characteristics of knitted fabrics on the clothing pressure of foundation. Five knitted fabrics of foundation were selected by different fiber types and blended ratios for the study. The dynamic characteristics of foundation wears made with five different fabrics were measured by KES-FB system method. The results of this study were as follows: 1. The tensile linearity and resilience of f1 were lower than those of other samples. While the tensile resistances of f1, f2 and f4 samples were high, the coefficients of friction of them were low. The bending rigidity and geometric roughness of f5 were higher than the others. 2. The clothing pressure of f3 all-in-one sample was the highest, and followed by f5, f4, f2 and f1, respectively. This result showed that the compression resilience affected on the clothing pressure greatly. 3. In terms of the clothing pressure by posture, the clothing pressure at $90^{\circ}$ bending posture was the highest and followed by that at standing and one-leg-up, respectively. The back part of abdomen was pressured most at $90^{\circ}$ bending posture.

  • PDF

Anesthetic and Cardiovascular Effects Induced by a Combination of Midazolam and Thiopental in Dogs (개에 있어서 Midazolam과 Thiopental 병용 투여시 마취 및 심순환기계에 미치는 영향)

  • 김희정;임희란;김휘율
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.352-362
    • /
    • 1999
  • Thiopental sodium is known as ultrashort-acting barbiturates and can be employed advantageously for numerous conditions. But thiopental has the side effects of cardiovascular and respiratory systems which has barbiturates and are depend on the dose of thiopental. The side effects are reduced when the thiopental is preceded by a tranquilizer and sedative. In these drugs, benzodiazepines have the minimal effects of cardiovascular and respiratory systems. In this study, the effects of midazolam preanesthetic administration, followed by thiopental anesthetic induction, on cardiovascular system and thiopental induction requirement were studied in 14 mixed breed dogs. Cardiovascular data were recorded baseline, after premedication of saline 0.45 ml/kg or midazolam 0.1, 0.2, 0.4, 0.8 mg/kg, intubation, and 5, 10, 15, 20, 30 minutes after intubation. Extubation, head-up, sternal recombency, standing, and walking recovery times were recorded. The results were summarized as follows; (1) The 0.1, 0.2, 0.4, and 0.8 mg/kg dosages of midazolam insignificantly decreased thiopental dose requirement necessary to accomplish intubation by 6, 20, 21 and 28%. (2) The 0.1, 0.2, 0.4, and 0.8 mg/kg dosages of midazolam insignificantly reduced the times of extubation, head-up, sternal recumbency, standing, and walking recovery. (3) Midazolam was effective in reducing the frequency and duration of arrhythmia after intubation. (4) Heart rates of preanestheic midazolam administraion groups increased after thiopental injection which insignificantly changed smaller than those of control group. (5) Arterial blood pressures did not vary significantly among groups.

  • PDF

Correlations between Muscle Strength of the Ankle and Balance and Walking in the Elderly (노인의 균형 및 보행과 족관절 근력과의 상관관계)

  • Kim, Kun;Seo, Sam-Ki;Yoon, Hui-Jong;Kim, Tae-Youl;Lee, Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.33-40
    • /
    • 2008
  • Purpose: This study was designed to investigate the correlations between muscle strength of the ankle and balance, walking in the elderly. Methods: Thirty-nine subjects were selected from a population of female volunteers. Measurement of balance ability included evaluation of timed "up and go", functional reach, and a one leg standing test. Measurement of walking analysis included evaluation of cadence, stride length, step length, and walking speed. Maximal voluntary isometric contraction (MVIC) of the ankle muscle strength was measured by use of a dynamometer. Results: For balance, there were significant negative correlations between timed "up and go" and the MVIC of the ankle dorsiflexor. There were significant positive correlations between one leg standing with the eyes closed and the MVIC of the ankle dorsiflexor. For walking, there were significant positive correlations between cadence, walking speed and the MVIC of the ankle dorsiflexor. Conclusion: This study showed that there were close relationships between muscle strength of the ankle dorsiflexor and walking and balance in the elderly.

  • PDF