• Title/Summary/Keyword: ST25.ST36

Search Result 270, Processing Time 0.029 seconds

A Comparison analysis of kinematics of lower extremities for 1st position jump in ballet between two types of ballet shoes (발레의 1st Position 점프 동작 시 신발 유형에 따른 하지의 운동학적 비교분석)

  • Youm, Chang-Hong;Park, Young-Hoon;Seo, Kook-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.327-340
    • /
    • 2003
  • The purpose of this study was to investigate the height of jump, angle of the ankle and knee, the angular velocity of the ankle and knee between two types of ballet shoes during a jump in the 1st position. The subjects were 5 female ballet majors of university in Busan the majors who have been dancing ballet for six years on the average. The conclusions are as follows: 1. The height of jump had no significant difference between two types of ballet shoes, and then the average of the height of jump with point shoes group ($20.24{\pm}4.62\;cm$) was a little higher than ballet shoes group ($17.50{\pm}4.05\;cm$). 2. The angle of the ankle had no significant difference for all events between two types of ballet shoes. The minimum angle of ankle joint was represented to $54.36_{\circ}$ at the E1 of the left ankle angle of the ballet shoes and the maximum value was showed $155.43_{\circ}$ at the E3 of the right ankle angle of the point shoes. 3. The angle of the knee had no significant difference for all events between two types of ballet shoes. The minimum angle of knee joint was represented to $99.54_{\circ}$ at the E1 of the left knee angle of the ballet shoes and the maximum value was showed $174.25_{\circ}$ at the E3 of the right knee angle of the point shoes. 4. The ankle velocity of the ankle had no significant difference for all events between two types of ballet shoes. The minimum angular velocity of the ankle was represented to 4.35 deg/s at the maximum height(E3) of the point shoes and the maximum value was showed 597.81 deg/s at the take-off(E2) of the right ankle angle of the point shoes. 5. The angular velocity of the knee had significant difference between two types of ballet shoes at the event 1(p<.05). The minimum angular velocity of the hee was represented to -1.68 deg/s at the maximum height(E3) of the point shoes and the maximum value was showed 360.25 deg/s at the take-off(E2) of the left knee angle of the ballet shoes. The other events had no significant difference between two types of ballet shoes.

Effects of Electroacupuncture on Parameters Related to Obesity in Adults with Abdominal Obesity:Three arm Randomized Single Blind Pilot Study (전침이 복부비만 성인의 비만관련 지표에 미치는 영향-무작위배정 단일 맹검 예비연구-)

  • Chung, Jie-Youn;Kim, Jong-In;Lee, Sang-Hoon;Kang, Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.43-57
    • /
    • 2010
  • Objectives : To investigate the effects of electroacupuncture on parameters related to obesity in adults with abdominal obesity. Methods : A three arm randomized single blind pilot study was conducted from Jan 4 to March 25, 2010 in Kyung Hee Oriental Medical Hospital. The subjects were 39 adults with abdominal obesity and were randomly divided by computer generated random table into 3 groups; EA(electroacupuncture), sham EA(sham electroacupuncture) and waitlist groups. Acupuncture points located at abdomen($CV_{12}$, $CV_6$, $ST_{25}$, $SP_{15}$, $SP_{14}$) and extremities($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) were inserted by disposable stainless steel needles and were stimulated 30 minutes with 24Hz, 0.27~1.3mA(tolerable strength), asymmetric biphasic continuous pulse wave form by STN-111 Stratek device in EA group. Two treatment sessions per week for 5 weeks(10 sessions in total) were done in EA and sham EA groups. The primary outcome measurement was WC(waist circumference), and the secondary outcome measurements included WHR(waist hip ratio), ASF(thickness of abdominal subcutaneous fat), and inbody measurements of BW(body weight), BMI(body mass index), BFR(body fat ratio) and VFA(visceral fat area), and also scores of BULIT-R(bulimia test revised), KoQoL(Korean obesity of QoL) and BSQ(body shape questionnaire). Results : All of 39 subjects were included in ITT(intention-to-treat) analysis. There were significant reductions in WC, WHR and ASF after 5-week electroacupuncture treatments and the percentage reductions were significantly greater than sham EA or waitlist group. There were no significant differences between groups in percentage reductions of other parameters(BW, BMI, BFR, VFA, BULIT-R, KoQoL and BSQ). But, there were continuous reductions in BW, BMI, BFR and VFA at 3 weeks after the end of treatment and there was significant reduction in BW compared with the baseline value in EA group. No seriously adverse effects were reported during the period. Conclusions : Electroacupuncture was more effective than sham electroacupuncture or no intervention on the reduction of WC, WHR and ASF in adults with abdominal obesity.

Evaluation of stress-induced analgesia in acupuncture analgesic effect - An Approach on diameters of acupuncture needles and acupuncture point needlings - (침진통 효과에서 스트레스에 의한 진통 효과 개입 여부 평가 - 침굵기, 침자극 부위를 중심으로 -)

  • Jeong, Byeong-Ju;Choe, Il-Hwan;Shin, Hee-Sup;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.65-80
    • /
    • 2008
  • Objective : In recent years, many investigators have questioned whether the analgesic effect of acupuncture is simply related to the stress-induced analgesia (SIA). However, there has been lack of studies on this issue. In this study, the stress levels induced by manual acupunctures are compared with the stress in animal experiment models. The experiments have been carried out with Sprague Dawley (SD) rats. Method : For stress level evaluation, Hot plate test has been used. Maximum Possible Effect (MPE) has been measured by checking the pre-test time and post-test time. Cortisol and corticosterone concentrations in serum were measured by enzyme-linked immunosorbent assay (ELISA). Results : In the hot plate test, MPE values of post-test time were significantly decreased after 10 minutes than after 5 minutes. Therefore, optimal time interval was chosen as 10 minutes. There was significant difference of MPE values between Suspension group and all other treatment groups. However, there were no significant differences of MPE values between Sham group and all other treatment groups. However, MPE values showed tendency to decrease when acupuncture needle diameter increased. MPE values of ST040, ST040(lido), NAP040(lido) groups were markedly decreased than that of Suspension group, while that of NAP040 group was substantially increased than that of Sham group increased in acupoint and nonacupoint models. Serum cortisol concentrations of treatment groups were not significantly different from that of Suspension and Sham groups. Serum corticosterone concentration of 0.25 mm group was substantially increased than that of compared with Sham group. Serum cortisol and corticosterone concentrations of treatment groups were not significantly different from those of Suspension and Sham groups in acupoint and nonacupoint models. Conclusion : From hot plate test and serum stress hormones concentrations, it is found that manual acupuncture treatment induces negligible stress or SIA on ST36. And the stress induced by manual acupuncture is more closely related to acupuncture point needlings than diameters of acupuncture needles.

  • PDF

Accuracy of Astigmatic Correction Using Toric Intraocular Lens by Position and Size of Corneal Incision (각막절개 위치와 크기에 따른 난시교정인공수정체의 난시교정의 정확성)

  • Park, Wookyung;Kim, Man Soo;Kim, Eun Chul
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.2
    • /
    • pp.126-134
    • /
    • 2019
  • Purpose: To assess the accuracy of toric intraocular lens (IOL) implantation by the location and size of the corneal incision. Methods: We retrospectively reviewed the medical records of 98 patients (98 eyes) who underwent phacoemulsification with toric IOL implantation from January 2014 to March 2017. The patients were divided into two groups: group 1 got an incision of the superior side of the cornea (n = 54) and group 2 received an incision on the temporal side of the eye (n = 44). For both groups, incisions were made at their steep corneal astigmatism axises. Each group was further divided into subgroups for whom different sized blades were employed (2.75 vs. 2.2 mm widths). We measured the refractive index and autokeratometric parameters. We postoperatively assessed residual astigmatism and any reduction thereof. Results: In both groups, uncorrected and best-corrected visual acuity, refraction cylinder astigmatism, and autokeratometric astigmatism improved statistically. Between two groups, corneal astigmatism decrease was not significant. Residual astigmatism also showed no significant differences between the two. Patients in both groups treated using 2.75 mm wide blades exhibited greater increases in corneal astigmatism. Conclusions: During cataract surgery, precise correction of astigmatism via toric IOL implantation is possible when surgically induced astigmatism is minimized by careful choice of the location and size of the corneal incision.

Relationship between Glycated Hemoglobin and Depression, Anxiety, Alexithymia, Stress Response in Diabetic Patients - A Preliminary Study - (당뇨환자에서 당화혈색소와 관련된 우울, 불안, 감정표현불능, 스트레스반응 - 예비적 연구 -)

  • Jeong, Jong-Hyun;Ko, Seung-Hyun;Hong, Seung-Chul;Han, Jin-Hee;Lee, Sung-Pil;Ahn, Yoo-Bae;Song, Ki-Ho
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2004
  • Objectives : This study was designed to investigate depression, anxiety, alexithymia, stress responses between well-controlled and poorly-controlled diabetic patients by glycated hemoglobin levels. Methods : The subjects were 55 diabetic patients(mean age : $49.9{\pm}9.9$, 27 men and 28 women) who were confirmed to have diabetes depending on the laboratory findings as well as clinical symptoms at the St. Vincent Hospital Diabetes Clinic, from Mar. 2004 to Aug. 2004. Korean version of Beck Depression Inventory(BDI), State and Trait Anxiety Inventory(STAI), Toronto Alexithymia Scale(TAS) and Stress Response Inventory(SRI) were used for assessment. Based on glycated hemoglobin levels, the patients were divided into 10 well-controlled group(below 7%) and 45 poorly-controlled group(above 7%). We compared BDI, STAI, TAS and SRI scores between two groups by independent t-test. Results 1) Well-controlled diabetics, compared with poorly controlled group, manifested decreased illness duration($12.2{\pm}55.4$months vs. $55.4{\pm}66.6 months)(p=0.000), but other demographic data showed no difference between two groups. 2) The STAI scores of poorly-controlled group were significantly higher in both state anxiety sores $(38.7{\pm}3.8 \;vs.\;43.7{\pm}6.7)(p=0.29)$ and trait anxiety scores$(36.9{\pm}5.7\;vs.\;41.5{\pm}6.4)(p=0.43)$ than well-controlled groups. 3) No significant differences were found in the score of BDI, TAS, SRI between well and poorly-controlled diabetic groups. Conclusion : The above results suggest that poorly-controlled diabetic patients are more likely to have higher anxiety level than well-controlled diabetic patients. However, there were no differences in depression, alexithymia, stress responses between two group. We suggest that physicians should consider integrated approaches for psychiatric problems in the management of diabetic patients.

  • PDF

Clinical Study of Duromedics Bileaflet Valve (Duromedics 판막의 임상적 연구)

  • Kim, Sang-Hyeong;Yu, Hong-Seok
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.667-675
    • /
    • 1990
  • From June, 15th, 1987 to June, 14th, 1989, 105 Duromedics bileaflet cardiac valve prostheses were implanted in 81 patients. Mitral valve replacement was done in 42 patients, 7 underwent aortic valve replacement, 28 underwent double valve replacement, & 4 patients underwent triple valve replacement. Concomitantly used valves were 13 cases; 11 cases were St. Jude Medical valves[M: SJM #29 X4, #27 X5, #25 X 1, T: SJM #33] & two cases were Carpentier Edwards bioprostheses[T: C - E #31X2]. The early mortality rate[within 30 days] was 3.7%[2 patients] & the late mortality rate was 7.4%[3 patients]. Follow-up was done on 72 surviving patients; mean follow-up period was 21.17$\pm$5.36 months. Anticoagulant-related hemorrhage was observed in two patients, possible prosthetic valvular endocarditis was observed in one patient and other specific valve-related complications were none. We concluded, therefore, that good clinical results & a low complication rate could be achieved with Duromedics bileaflet valve in short-term follow-up, & long-term follow-up was also necessary.

  • PDF

Restoration and Scientific Analysis of Casting Bronze Type in Joseon Dynasty (조선왕실 주조 청동활자의 복원과 과학적 분석)

  • Yun, Yong-Hyun;Cho, Nam-Chul;Lee, Seung-Cheol
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.207-217
    • /
    • 2009
  • After replicating 10 bronze types such as Gyemija, Gyeongjaja, Eulhaeja, etc. before the Imjin war, we studied the change of microstructure from each casting process, method, and alloy ratio by Gyechukja replicated from "Donggukyeojiseungnam". We selected the average of compositions of Eulhaeja in the National Museum of Korea as the standard(Cu 86.7%, Sn: 9.7%, Pb: 2.3%) of bronze types, so we decided on the alloy's composition of Cu 87%, Sn 15%, Pb 8% added to 5% Sn and Pb contents because of evaporating the Sn and the Pb. Before replicating major metal types, we made master-alloy first, melting it again, and then replicated metal types. The composition of the 1'st replicated Gyechukja showed the range of Cu 85.81~87.63%, Sn 9.27~10.51%, Pb 3.05~3.19%. The 2'nd replicated Gyechukja made using the branch metal left after casting the 1st replica. The 2nd replicated Gyechukja showed the composition range of Cu 87.21~88.09%, Sn 9.06~9.36%, Pb 2.80~3.05%. This result decreases a little contents of Sn and Pb as compared with metal types of the 1st replica. However, it's almost the same as the Eulhaeja's average composition ratio in the National Museum of Korea. As a result of observing the microstructure of restored Gyechukja, it showed the dendrite structure of the typical casting structure and the segregation of Pb. There is no big difference of microstructure between the 1st and the 2nd restored metal types, even though the 2nd restored types partially decreases the eutectoid region in comparison with the 1st types. The systematic and scientific restoration experiment of metal types using Joseon period will be showed the casting method and alloy ratio, and this will be of great help to the study of restoration metal types in the future.

  • PDF

Effects of Fixed-intensity and Varied-intensity Electroacupuncture in Pain and Sensory Threshold in Patients with Chronic Tension Headache (전침 자극 강도에 따른 만성 긴장성 두통 환자의 통증과 감각역치 변화 연구)

  • Kwon, You-Jung;Lee, Dong-Hua;Lee, Ung-In;Park, Kyung-Mo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.25-34
    • /
    • 2012
  • Objectives : This study was conducted to investigate the effects of fixed-intensity and varied-intensity electroacupuncture in pain and sensory threshold concerning parameters visual analogue scale(VAS), brief pain inventory(BPI) and quantitative sensory testing(QST), among chronic tension headache patients. Methods : Thirty patients with chronic tension headache were randomly assigned to three groups and received different kinds of electroacupuncture at $ST_{36}$ and $ST_{37}$. Group A received fixed-intensity electroacupuncture(fixed-EA), group B received varied-intensity electroacupuncture (varied-EA), and group C received only acupuncture treatment without electrical stimulation as a control group. The intervention was given three times per week, and continued in two weeks. All the experiments were conducted blindly. Results : Fixed-EA group showed a significant decrease of VAS and BPI compared to the baseline measurement, while both varied-EA and control group did not. Of the parameters of QST, subtraction of heat pain threshold(HPT) and cold pain threshold(CPT) slightly increased in all groups, but this was not significant. Conclusions : These results suggest that fixed-EA reduce pain and improve quality of life in patients with chronic tension headache and that acupuncture may regulate patient's pain sensitivity through changing sensory threshold.

Applicability of Oncoplastic Breast Conserving Surgery in Asian Breast Cancer Patients

  • Lim, Geok-Hoon;Pineda, Lea Angela
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3325-3328
    • /
    • 2016
  • Background: There are limited studies on oncoplastic breast conserving surgery in Asian women. We aimed to determine the applicability and safety of oncoplastic surgery, highlighting the specific circumstances when it will be most useful and compare our preferred technique with the worldwide practice of oncoplastic approaches. Materials and Methods: Breast cancer patients who underwent oncoplastic breast conserving surgery at a single institution from 1st May 2014-31st March 2015 were included. Data on patient demographics, tumor characteristics and the type of oncoplastic surgery performed were collected. Results: Nineteen breast cancer patients were identified. 42.1% of patients had grade I ptosis. The indications for surgery included a large tumor to breast size ratio (52.6%), multifocal/multicentric lesions (36.8%) and asymmetric breasts (10.6%), averting a mastectomy in 89.4%. Round block was the commonest technique in 63% of patients, in contrast to the inverted T pattern most frequently used in renowned institutions in the West. Mean and median tumor size and weight of specimen were 29.4/25mm (11 - 75mm) and 77g/64g (10 - 246g) respectively. Re-excision rate was 10.5%. Complete mastectomy was performed for one patient. One patient developed wound dehiscence which was treated conservatively. Cosmetic outcome was rated as excellent/good by 94.7% of patients. The patients remained clinically well after a median 16 months follow up. Conclusions: Oncoplastic breast conserving surgery is useful in a specific subgroup of Asian patients with a relatively small breast volume and minimal ptosis. Round block was the commonest technique in our series, in contrast to the worldwide utility of oncoplastic techniques. It is oncologically safe and has good cosmetic outcomes.

Size, Shape, and Crystal Structure of Silica Particles Generated as By-products in the Semiconductor Workplace (반도체 작업환경 내 부산물로 생성되는 실리카 입자의 크기, 형상 및 결정 구조)

  • Choi, Kwang-Min;Yeo, Jin-Hee;Jung, Myung-Koo;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.36-44
    • /
    • 2015
  • Objectives: This study aimed to elucidate the physicochemical properties of silica powder and airborne particles as by-products generated from fabrication processes to reduce unknown risk factors in the semiconductor manufacturing work environment. Materials and Methods: Sampling was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. Thirty-two powder and airborne by-product samples, diffusion(10), chemical vapor deposition(10), chemical mechanical polishing(5), clean(5), etch process(2), were collected from inner chamber parts from process and 1st scrubber equipment during maintenance and process operation. The chemical composition, size, shape, and crystal structure of silica by-product particles were determined by using scanning electron microscopy and transmission electron microscopy techniques equipped with energy dispersive spectroscopy, and x-ray diffractometry. Results: All powder and airborne particle samples were composed of oxygen(O) and silicon(Si), which means silica particle. The by-product particles were nearly spherical $SiO_2$ and the particle size ranged 25 nm to $50{\mu}m$, and most of the particles were usually agglomerated within a particle size range from approximately 25 nm to 500 nm. In addition, the crystal structure of the silica powder particles was found to be an amorphous silica. Conclusions: The silica by-product particles generated from the semiconductor manufacturing processes are amorphous $SiO_2$, which is considered a less toxic form. These results should provide useful information for alternative strategies to improve the work environment and workers' health.