• 제목/요약/키워드: SS removal

검색결과 475건 처리시간 0.027초

대청호 주원천 인공습지의 오염물질 정화효율 평가 (Evaluation of treatment efficiencies of pollutants in daecheong lake juwon stream constructed wetlands)

  • 김태훈;성기은;하덕호;김동희;허순욱;최충식
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.211-222
    • /
    • 2015
  • This study focused on evaluating the efficiency of the removal of non-point source pollution by Daecheong Lake Juwon Stream constructed wetlands. The constructed wetland system is a surface flow type designed in the year 2007 for purifying eutrophic water of Daecheong Lake Juwon Stream. The value of conductivity, suspended solids(SS), chemical oxygen demand using a potassium permanganate($COD_{Mn}$), five-day biochemical oxygen demand($BOD_5$), total nitrogen(T-N), total phosphorous(T-P), and pH in inflow averaged 220.2, 2.46, 3.33, 1.34, 2.00, 0.04 mg/L and 7.24, respectively and in outflow averaged 227.9, 1.12, 3.34, 0.87, 1.16, 0.02 mg/L and 7.45, respectively. The average removal efficiency of constructed wetlands was 30 % for SS, 22 % for $BOD_5$, 45 % for T-N and 31 % for T-P. The removal rates of SS, $BOD_5$ and T-N in the spring, summer and autumn were higher than those in winter. The removal rate of T-P was not significant different in all seasons. The amounts of pollutants removal in the constructed wetlands were higher in the order of $3^{rd}$ < $2^{nd}$ < $1^{st}$ wetland for SS and T-P, $2^{nd}$ < $3^{rd}$ < $1^{st}$ wetland for $BOD_5$ and T-N. Therefore, our findings suggest that the constructed wetlands could well treat the eutrophic Daecheong Lake Juwon Stream waters.

화학적 처리에 의한 1차 하수처리장의 처리효과 개선 -현장시험을 중심으로- (Chemically Enhanced Primary Treatment at D Wastewater Treatment Plant)

  • 곽종운;김승현;이찬원
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.99-108
    • /
    • 1997
  • This study examined the feasbility of upgrading D waste water treatment plant which treats incoming wastewater by primary sedimentation only. By adding 20-40 ppm of Hi-PAX into the outlet of the aerated grit chamber, BOD and SS removal efficiences were improved from 29% and 36% to 53 % and 73%,respectively. However, chemically enhanced primary treatment failed to meet the upcoming wastewater quality standard(BOD and SS <20 mg/l) consistently. This was suspected to result from the deteriorated plant return stream. The wastewater treatment by chemical treatment should have increased the amount of the sludge to be removed as the sludge production was increased. Chemically enhanced primary treatment is anticipated to consistently produce effluent of the 1996 standards quality by adjusting the amount of the sludge to be removed. Besides BOD and SS removal, chemically enhanced primary treatment resulted in the improved T-P removal from 30% to 64-74%. However, such benefit was not observed in T-N removal. Improved T-P removal will be expected to help control water pollution in Masan bay.

  • PDF

Cavitation에 의한 슬러지 가용화와 PGA를 이용한 하수고도처리에 관한 연구 (Advanced Wastewater Treatment using Sludge Solubilization by the Cavitation and PGA addition)

  • 김동하
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.449-454
    • /
    • 2008
  • Some pretreatment methods have been proposed to enhance the biodegradability and to shorten the hydrolysis reaction time. By means of efficient pretreatment the suspended solids (SS) can be made of better accessible for the anaerobic bacteria. There are several ways how this can be accomplished, which include biological, mechanical, thermal, and chemical methods. For the sludge solubilization using the cavitation phenomenon, we have tried to develop a pretreatment process consisted of a reactor and pumps. The objectives of this study were to develop a advanced wastewater treatment consisted of IABR and the cavitation with PGA. The most effective removal for organic matter and nutrients were occured when both cavitation pretreatment and ${\gamma}$-PGA were applied at the IABR process. Only small portion of ${\gamma}$-PGA at a rate of 1.38mg/L, was enough to improve sedimentation ability, SS removal efficiencies, and sludge volume reduction. After the sludge solubilization by the cavitation, SCOD increased to 193% and SS decreased to 36%. The removal ratio of BOD was 94.5%, T-N removal ratio was 85.5% and T-P removal ratio was 84.9%. The combination process of the IABR with the cavitation and PGA addition seems to be very effective alternative wastewater treatment process.

SBR 및 BS-SBR 처리의 공정변화 연구 (Process variations in SBR and BS-SBR treatment)

  • 양형재;정윤철;신응배
    • 환경위생공학
    • /
    • 제12권1호
    • /
    • pp.59-68
    • /
    • 1997
  • 이 연구에서는 SBR에 Rotating disks를 부착하여 회전하면서 두 원판 사이에서 전단력이 발생하는 BS-SBR을 이용하여 용해성 유기물질 제거율과 슬러지 분리에 대해 비교 검토하였다. BS-SBR 공정에서는 부유성 활성슬러지와 생물학적 고정막에 대해 동시처리 되어 높은 처리효율을 보였다. SCOD 제거율은 SBR보다 높은 97%를 보였다. 처리수의 평균 SS 농도는 $4.8mg/{\ell}$ 정도로 나타났고, 1-cycle/d 및 3-cycle/d 모두 $10mg/{\ell}$ 이하를 유지하여 매우 효과적임을 알 수 있었다. 슬러지 침전 특성은 SBR과는 상이한 매우 좋은 결과를 보였다. 운전 중 슬러지는 진한 갈색으로 플록이 잘 형성되었고, 그 크기는 SBR에서 보다 크다는 것이 눈으로 확인할 수 있을 정도였다.

  • PDF

Vortex Screen장치를 이용한 강우유출수내 미세입자 처리특성 분석 (Performance Evaluation of Vortex Screen for Treatment of Fine Particles in Storm Runoff)

  • 이준호;정윤희;방기웅
    • 대한환경공학회지
    • /
    • 제31권4호
    • /
    • pp.256-262
    • /
    • 2009
  • 도시지역 비점오염부하를 저감하는 장치 중에서 수리동력학적 분리장치(HDS)는 가장 많이 이용되고 있다. 본 연구에서는 HDS장치 유형 중에서 Vortex Screen 장치를 실험실 규모로 개발 및 제작하여 강우유출수 처리특성을 분석하였다. 강우유출수내 입자물질을 모의하기 위하여 실험에 사용한 시료는 합류식 하수관거의 맨홀 바닥 퇴적물질, 도로변 측구의 퇴적물질, 소각장 fly ash, polyvinyl chloride (PVC)분말 등의 시료를 대상으로 하였다. 유입유량의 변화를 주었을 때 처리장치 본체에서 약 2분이 경과한 후 안정된 상태에서 유입수와 유출수 시료를 동시에 채수하였다. 수면적부하율은 110∼1,550 $m^3/m^2$ day의 범위로 운전하였으며, 유입수 SS농도의 범위는 141~1,986 mg/L로 하였다. Vortex Screen을 이용하여 다양한 입경과 밀도들 가진 입자들을 대상으로 수면적부하율과 하부배출유량비를 운전조건으로 하여 처리특성을 분석한 결과 제거효율에 영향을 주는 인자 중, 월류유량에 대한 하부배출유량 비율($Q_U/Q_O$), $Q_U/Q_O$값이 10%에서 20% 증가 시 SS 제거효율은 6% 증가하는 특성을 나타내었다. 도시지역의 대표적인 입경을 가진 퇴적물질 125<$d_p$<300 ${\mu}m$를 대상으로 처리능을 분석한 결과 SS, COD 제거효율 범위는 각각 68.0~ 81.0%, 53.1~71.9%를 나타내었다. 수면적 부하율이 증가함에 따라 처리효율은 유입부 유도판을 설치한 경우가 설치하지 않은 경우보다 10~20% 향상되는 것으로 분석되었다.

연속회분식반응조를 이용한 생물학적인 인 제거 연구 (Biological Phosphorus Removal using the Sequencing Batch Reactor Process)

  • 양형재;신응배;정윤철;최훈근
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.533-539
    • /
    • 2000
  • A bench-scale reactor using SBR process was experimented with an synthetic wastewater. The main purpose of this investigation was to evaluate applicability in the field and process removal efficiencies in terms of BOD and T-P and its corresponding kinetic parameters. Removal rate of phosphorus was 77% in terms of total phosphorus. Effluent concentrations were $9.8mg/{\ell}$ BOD and $1.1mg/{\ell}$ T-P. Effluent quality was maintained consistently stable by controlling decant volume and operating cycles. The efficiency for phosphorus removal was increased due to decrease in BOD-SS loading value in the range of $0.25{\leq}$aeration time ratio${\leq}0.52$.

  • PDF

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

저수지 유입하천 현장적용실험을 통한 수질정화효율 평가 (Evaluation of Pollutant Removal Efficiency through Field Test-Bed Experiment in the Rural Small Stream)

  • 최선화;오종민;김태훈
    • 한국수자원학회논문집
    • /
    • 제47권12호
    • /
    • pp.1135-1143
    • /
    • 2014
  • 본 연구에서는 사상성 조류로 구성된 수질정화시설의 수질정화효율을 평가하고자 충남 서산시 음암면에 소재한 성암저수지 유입하천 홍수부지에 test-bed를 설치하고 유입하천수를 대상으로 현장적용실험을 실시하였다. 수질항목별로 정화효율을 평가한 결과, SS 80.9%, COD 74.6%, T-N 76.8%, T-P 84.4%, DTN 93.8%, DTP 98.3%의 제거효율을 보였다. 수온에 따른 정화효율은 수온이 약 $20^{\circ}C$로 유지되어 수질정화효율에 미치는 영향은 없는 것으로 나타났다. 수리학적 체류시간(HRT)은 SS 및 TP 처리효율과 유의한 상관성이 있는 것으로 나타났고, 체류시간을 5일로 했을 때 SS, TP 처리효율이 좋은 것으로 나타났다. 유입수의 COD/TN에 따른 처리효율은 TN, TP 모두 C/N비가 낮을수록 증가하였고, 유입수의 COD/TP에 따른 처리효율도 C/P비가 낮을수록 TN, TP 모두 처리효율이 증가하는 것으로 나타났다.

에폭시수지 공정에서 발생되는 고염 폐수로부터 황산알루미늄과 PAC 응집제를 이용한 응집/고액분리 조건 최적화 (Optimizing of Coagulation and Solid-Liquid Separation Conditions Using Aluminum Sulfate and Poly-Aluminum Chloride Coagulants from Brine Wastewater Discharged by the Epoxy-resin Process)

  • 이창한;김유진;문성현;권성헌;안갑환
    • 한국환경과학회지
    • /
    • 제31권1호
    • /
    • pp.1-8
    • /
    • 2022
  • In this study, solid-liquid separation conditions for coagulation and sedimentation experiments using inorganic coagulant (aluminum sulfate and Poly-Aluminum Chloride (PAC)) were optimized with brine wastewater discharged by the epoxy-resin process. When the turbidity and suspended solid (SS) concentration in raw wastewater were 74 NTU and 4.1 mg/L, respectively, their values decreased the lowest in a coagulant dosage of 135.0 - 270.0 mg Al3+/L. The epoxy resin was re-dispersed in the upper part of wastewater treated above 405.0 mg Al3+/L. The removal efficiencies of turbidity and SS via dosing with aluminum sulfate and PAC were evaluated at initial turbidity and SS of 74 - 630 NTU and 4.1 - 38.5 mg/L, respectively. They increased most in the range from 135.0 - 270.0 mg Al3+/L. The solid-liquid separation condition was quantitatively compared to the correlation of SS removal efficiency between the coagulant dosage and SS concentration based on the concentration of aluminum ions. The empirical formula, R = beaD, shows the relationship between SS removal efficiency (R) and coagulant dosage (D) at 38.5 mg/L; it produced high correlation coefficients (r2) of 0.9871 for aluminum sulfate and 0.9751 for PAC.

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.