• Title/Summary/Keyword: SS 농도

Search Result 632, Processing Time 0.032 seconds

The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel (3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향)

  • 오세욱;도영문;박수영;김재철;김광영
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF

Water Treatment By VPMF (VPMF를 이용한 수처리방법)

  • 최충현;유승철
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.107-108
    • /
    • 1997
  • 1. 서론 : 분리막 시설의 전처리방법에는 Sand Filter, 유니필터 그리고 케트리지(5$\mu$m) 필터가 상용되어 왔다. 그러나 Sand Filter와 유니필터 등은 설치비용은 저렴하지만 처리수질이 5$\mu$m 케트리지 필터보다 떨어지므로 분리막시설의 전처리로 미흡하다. 통상적인 분리막 시설의 설계시에 사용되는 5$\mu$m 케트리지 필터는 역세가 불가능하므로 교체하지만 대규모의 수처리설비나, SS의 농도가 높은 경우에 있어서 분리막의 전처리시설로 적합치 않다. 한편 5$\mu$m 케트리지 필터는 대체하기 위한 정밀여과장치가 많이 개발되고 있으며 Z필터, BMF, Cross Filter 등이 그러한 여과장치들이다. 본 글에서 소개할 VPMF(Variable Pore Micro Filter, 가변세공 정밀여과장치)도 그러한 여과장치와 유사한 기능과 성능을 가진 정밀여과장치이다. 본 연구에서는 Caolin을 이용하여 50~100ppm 사이의 SS농도하에서 VPMF의 처리수질, 역세효율, SS포집능력 등을 평가해 볼 것이다.

  • PDF

Sensitivity Analysis of Parameters in a Depth Averaged Two-Dimensional Sediment Transport Model (수심적분 2차원 유사이동모형에 관계된 인자들의 민감도분석에 관한 연구)

  • Seo, Sang-Won;Yun, Byeong-Man
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.1
    • /
    • pp.115-120
    • /
    • 1998
  • In this paper, a depth-averaged two-dimensional transport model is introduced, and its error bound is presented as the results of sensitivity analysis. The results show that the calculated SS concentration is highly dependant on Manning roughness coefficient, mixing coefficient. fall velocity. and critical shear stress. On the other hand, water level and dispersion coefficient are proved to be less significant in the variation of SS concentration.

  • PDF

Analysis of Correoation between Water Quality Parameters in Goljicheon Basin (골지천 유역의 수질항목간 상관관계 분석)

  • Yu, Na Yeong;Shin, Min Hwan;Park, Bae Kyung;Kang, Tae Sung;Kim, Jong Gun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.403-403
    • /
    • 2021
  • 비점오염물질은 강우에 의해 유출되며 계절적, 자연적 편차가 크게 나타나고, 오염원이 광범위하게 산재하고 있어 오염물질의 발생량과 부하량의 관리가 쉽지 않다. 따라서 비점오염원 관리지역은 오염물질이 하천에 미치는 수질 특성을 파악하는 것이 중요하다. 그러나 수질항목만으로 하천의 수질 특성을 파악하기에는 어려움이 있으며, 수질 특성을 파악하기 위해 다양한 분석방법이 필요하다. 본 연구에서는 비점오염원 관리지역 중 골지천 유역의 수질 특성을 파악하기 위해 통계분석 기법을 활용하여 수질항목간의 상관관계를 분석하고자 하였다. 2017년부터 2019년까지 골지천 유역 내 5개 지점에 대하여 비강우시 23회, 강우시 지점별 173회~196회의 모니터링 결과를 이용하였으며, EC, 탁도, BOD5, SS, T-N, T-P, TOC의 수질항목을 이용하여 Pearson 상관관계 분석을 실시하였다. 상관관계 분석 결과 비강우시 분석 결과 EC는 -0.06~-0.32, T-N은 0.19~0.37로 낮은 상관성을 갖는 것으로 나타났으며, EC와 T-N을 제외한 탁도와 BOD5, SS, T-P, TOC의 경우 서로 0.6 이상의 상관성을 갖는 것으로 나타났다. 특히, 탁도와 SS, T-P, T-P와 TOC는 0.9 이상의 높은 상관성을 갖는 것으로 나타났다. 강우시 분석 결과 EC는 비강우시와 유사하게 -0.07~-0.24로 낮은 상관성을 갖는 것으로 나타났으며, TOC를 제외한 탁도, BOD5, SS, T-N, T-P의 경우 서로 0.6 이상의 상관성을 갖는 것으로 나타났다. TOC의 경우 BOD5, SS와 0.6 이상의 상관성을 갖는 반면 탁도, T-N, T-P와는 0.45, 0.44, 0.57로 다른 항목에 비해 다소 낮은 상관성을 갖는 것으로 나타났다. 비강우시 T-N은 기저 유출에 의한 영향으로 높은 농도를 나타내 다른 항목에 비해 상관성이 낮은 것으로 나타났으며, 강우시에는 비점오염물질의 유입으로 인하여 모든 항목에서 비슷한 상관성을 보이는 것으로 나타났다. 본 연구 결과 탁도와 SS, T-P의 상관성이 비강우시 0.93, 강우시 0.78로 상당히 높은 것으로 나타나, 탁도를 측정하여 SS와 T-P로 환산하여 측정하는 방법에 대한 기초자료로 활용될 수 있을 것으로 판단된다. 그러나 연구 유역의 지형적 특성이 배제되었기 때문에 추후에 이를 반영한 연구가 필요할 것으로 판단된다.

  • PDF

A study of photoreflectance on the surface characteristics in n-GaAs treated with Ar plasma (아르곤 플라즈마로 처리한 n-GaAs의 표면특성에 관한 Photoreflectance 연구)

  • 이동율;김인수;김동렬;김근형;배인호;김규호;한병국
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.359-363
    • /
    • 1997
  • We have investigated the surface characteristics of n-GaAs (100) treated with Ar plasma (40 W, 5~120 sec) by photoreflectance (PR) measurement. With increasing Ar plasma treatment time, the intensity of $E_0$ peak observed to the minimum at 5 sec. The surface electric field ($E_0$), net carrier concentration ($N_P-N_A$), and surface state density ($Q_{SS}$ are $1.05{\times}10^5V/cm$ and $1.31{\tiems}10^{17}cm^{-3}$ and $1.64{\times}10^{-7}C/m^2$, respectively. These values were about 57.1, 81.4 and 56.9% smaller than those of bulk n-GaAs. On the other hand, the concentration of compensation centers ($N_A$) was maximum with value of $5.75{\times}10^{17}cm^{-3}$ at 5 sec. And penetration depth of defects generated after treated with Ar plasma was about 450 $\AA$ from surface.

  • PDF

Treatment of Contaminated Groundwater Containing Petroleum and Suspended Solids Using DAF and Mixed Coagulation Processes (DAF와 혼화응집공정을 이용한 현탁성 고형물 함유 유류 오염 지하수 처리)

  • Lee, Chaeyoung;Jang, Yeongsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.25-32
    • /
    • 2010
  • Contamination of soil and groundwater by the compounds of hydrocarbon petroleum has been widely accepted as the main cause that harms the environments and health. To remove those pollutants, absorbing clothes, activated carbons, or oil-water separation devices with the gravity method are employed for treatment. However, those materials and devices cannot remove the emulsion pollutants despite of their efficiency for removing free products. Therefore, we investigated the problems which occur during the groundwater treatment for the highly concentrated suspended solid particles, which can be resulted from excavation, and to propose methods to remove TPH(Total Petroleum Hydrocarbon). After coagulation experiment with high molecular polymers, the concentration of SS(Suspended Solids) and COD(Chemical Oxygen Demand) turned to satisfy the groundwater quality criteria within 5 minutes while the concentration of TPH failed to meet the water quality standard of effluent. Consequently, the water quality criteria for effluent could not be met by single DAF(Dissolved Air Flotation) process. However all water quality criteria could be satisfied after 20 minutes when coagulation reactions are carried out simultaneously in the DAF reactor.

Biological Perchlorate Reduction in Municipal Sewage (도시하수에서 생물학적 퍼클로레이트의 환원)

  • Choi, Hyeoksun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.675-680
    • /
    • 2013
  • This research was done to evaluate the potential for destruction of perchlorate in municipal sewage. Laboratory experiments were conducted in flasks containing 3 liters of raw sewage. Sewage was mixed with defined amount of perchlorate and various additives. Perchlorate reduction in sewage did occur, but was quite variable, ranging from 0 to 72% over 72 hour. Addition of even a small amount of perchlorate acclimated biomass (167 mg/L SS) significantly reduced the lag and resulted in complete perchlorate removal. Perchlorate reduction in sewage-brine mixtures was inhibited when the dissolved oxygen level was greater than 2 mg/L, and when the mixture salinity was relatively high (conductivity = 14 mS with equivalent TDS = 8 g/L). When nitrate ($NO_3{^-}$) was present with perchlorate in the laboratory flask tests of sewage-brine mixtures, nitrate reduction proceeded first. A significant amount of nitrite ($NO_2{^-}$) accumulated in the sewage-brine mixtures, accounting for about 66% of initial nitrate nitrogen ($NO_3$-N).

A Study on the Removal Efficiency Depending on Changes of Inflow Conditions in Vortex typed Non-point Pollutants Treatment Facility (와류형 비점오염저감시설의 유입 조건에 따른 제거효율 연구)

  • Yoon, Geun-Ho;Choi, Gye-Woon;Lee, Min-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.494-494
    • /
    • 2012
  • 비점오염이란 도시, 도로, 농지, 산지, 공사장 등 불특정 장소에서 발생되는 오염을 말하며 건기 시에는 오염물질이 토지에 축적되었다가 강우 발생 시 강우와 함께 유출되어 관리에 많은 어려움이 있다. 유출된 오염물질은 특별한 전처리 없이 하천이나 호소로 유입되어 각종 수질오염, 부영양화 및 생활환경에 많은 영향을 받게 되며 상수원수에 문제가 발생하게 된다. 비점오염원의 특징은 초기강우 유출수는 고농도이며 토사, 협잡물 등이 많이 포함되어 있다. 초기강우 발생형태는 수로의 형태, 노면상태 유역현상 및 강우도달시간 등 유역의 특성에 따라서 달라지며, 토지이용상황, 하수도 정비여부 등에 따라서 오염물질의 종류와 농도가 변한다. 도시지역과 도로주변에는 먼지, 쓰레기, 마모된 타이어 등이 축적되며, 임야 및 산림에서는 비료, 축분, 대기오염물질의 강하물 등이 축적이 되어 강우 시 빗물에 씻겨 인근 수계로 직접 방류된다. 팔당상수원 비점오염원 최적관리사업 기본계획 및 타당성조사사업이 실시되어 비점오염저감시설의 설치대상 대표지점이 선정되었다. 그리고 각 배수구역의 특성에 맞는 최적관리기술이 제시되었다. 하지만 몇몇 시설들은 기대한 결과에 못 미치는 성과를 내고 있다. 따라서 이번 연구에서는 이러한 비점오염저감시설의 시설형 중 하나인 와류형 비점오염저감시설의 운용에 따른 효율성 분석에 관한 연구를 실시하였다. 실험장치는 현재 운영되고 있는 와류형 비점오염저감시설 참고하여 실험장 조건에 맞춰 1/4축적의 정상모형을 제작하였고 저감시설로 유입되는 원수의 유량과 단차를 변화시켜 실험하였다. 저감시설의 유입조건이 변하게 되면 시설 내 유속, 체류시간 등 운전조건이 바뀌게 되므로 제거효율도 변하게 될 것이다. 저감효율산정은 시설로 유입된 유입수와 유출수의 SS농도를 이용하여 산정하였다. 와류형저감시설의 SS제거효율을 연구한 결과, 모형에서 유량 $0.0016m^3/s$, 단차 10cm 인 조건에서 8.7%로 가장 높은 효율이 측정되었다. 이를 원형에서의 조건으로 환산하면 유량 $0.0512m^3/s$, 고수조와 저감시설의 단차 40cm일 경우 가장 높은 효율이 나타난다. 이와 같은 이유는 시설에 유입되는 유량이 증가 할수록 내부의 유속이 증가해 저감시설 내 처리수의 체류시간 감소와 교란이 발생하여 저감효율이 떨어지는 것으로 사료된다.

  • PDF

Application of a Pond System to Korea for Treatment and Recycling of Wastewater (하수 처리 및 재활용 연못시스템의 국내 응용)

  • Yang, Hongmo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.108-117
    • /
    • 1995
  • The applicability to Korea is examined of a pond system which treats and recycles wastewaters. Air temperature and solar radiation of the pond systems at Corinne, Utah, and Eudora, Kansas, which are located in temperate regions of the U.S., are compared with those of Kimpo lying in the mid-western part of Korea. Analyzed are also $BOD_5$ and SS concentrations, algal concentrations, pH levels, and water temperature of the two systems. Air temperature of Kimpo is quite similar to that of the two systems, and solar radiation of Kimpo is more conducive than that of the systems to the growth of algae during summer. Analysis of $BOD_5$ and SS concentrations in the final effluent of the systems shows that they meet the secondary treatment standards. The study demonstrates that wastewater treatment pond system which is similar in design to the systems can be reliably utilized at Kimpo, Korea. A model is proposed which can integrate a pond system with aquaculture and agriculture.

  • PDF

Development of the Sub-soil Storage System for Utilization Urban Instream Flow of Rainfall Runoff (우수유출수의 도시하천 유지유량 활용을 위한 지하저류시스템 개발)

  • Choi, Gye-Woon;Choi, Jong-Young;Kim, Suk-Dong
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.163-172
    • /
    • 2004
  • In this paper, the sub-soil storage system for utilizing urban instream flow of rainfall runoff was developed and examined through experiments. The artificial rainfall facility and sub-soil storage were installed in the experimental area. The effect of the water qualify improvement and the storage effect were analyzed through the several experiments. Through the experiments of rainfall intensity variation, which are the rainfall intensity of 20mm/hr, 30mm/hr, 40mm/hr, 50mm/hr was indicated SS concentration can be reduction until 68%. Also, the ration of the storage volume is varied from 42.8%∼79.9% based on the rainfall intensity. The reduction rate of the BOD, CO $D_{Mn}$, SS, T-N, T-P was 30%, 42%, 68%, 39%, 26%. As the result, water quality of runoff and efficient of runoff reduction by the system are much improved. The rainfall runoff with the installation of sub-soil storage could be used for instream flow.