• Title/Summary/Keyword: SQUID

Search Result 939, Processing Time 0.036 seconds

Quality Characteristics for Doenjang Using Squid Internal Organs (오징어 내장을 첨가한 된장의 품질 특성)

  • Seo, Ji-Hyung;Jeong, Yong-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.89-93
    • /
    • 2001
  • The quality characteristics of doenjangs added with squid internal organs were evaluated. The contents of moisture, salt and amino type nitrogen were similar among traditional doenjang and squid doenjang(I, II, III). But the color values were different. pH and peroxide value(POV) were high in squid doenjangs. Squid doenjang(I, II, III) contained much taurine($53.26{\sim}170.90\;mg%$) and ${\alpha}-aminobutyric$ acid($35.17{\sim}151.00\;mg%$) which were not detected in traditional doenjang. Also aspartic acid and glutamic acid related to palatable taste, threonine, serine and proline related to sweet tastes were much more in squid doenjangs. Contents of isoleucine and leucine related to bitter taste were similar with traditional doenjangs. Comparing with traditional doenjang, volatile flavor components in squid doenjangs had high ratio of esters such as ethylbutylether and aldehydes such as 2-propanal, 3-methylbutanal in contrast with low alcohols. Especially ethylbutylether, 2-propanol, 3-methyl-1-butanal, 2,6,10,14-tetramethyl-pentadecane, ethyllinoleate were only in squid doenjangs. From the sensory evaluation after 4 weeks, squid doenjang(II) added with 10% squid internal organs obtained the highest scores for taste as differing from traditional soybean paste and squid doenjang(I). But the total acceptability was higher in traditional doenjang because of strong fishy smell and dark color in squid doenjang. After 8 weeks squid doenjang(I, II) obtained high scores for taste and low scores for color and flavor.

  • PDF

Fabrications and measurements of single layer YBCO dc-SQUID magnetometers designed with parallel-loop pickup coil (Parallel-loop 검출코일을 가지는 단일층 YBCO dc-SQUID 자력계의 제작 및 특성 연구)

  • 유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • We have designed and fabricated the single-layer high $T_{c}$ SQUID magnetometer consisting of a directly coupled grain boundary junction SQUID with an inductance of 100 pH and 16 nested parallel pickup coils with the outermost dimension of 8.8 mm ${\times}$ 8.8 mm. The magnetometer was formed from a YBCO thin film deposited on an STO(100) bicrystal substrate with a misorientation angle of $30^{\circ}$. The SQUID magnetometer was further improved by optimizing the multi-loop pickup coil design for use in unshielded environments. Typical characteristics of the dc SQUID magnetometer had a modulation voltage of 40 $\mu\textrm{V}$ and a white noise of $30fT/Hz^{1}$2/. The SQUID magnetometer exhibited a 1/f noise level at 10 Hz reduced by a factor of about 3 compared with that of the conventional solid type pickup coil magnetometers and a very stable flux locked loop operation in magnetically disturbed environments.s.

  • PDF

Wide-bandwidth SQUID Current Amplifier and Control Electronics for X-ray Microcalorimeter (X-선 미소열량계 신호 검출을 위한 광대역 SQUID 전류증폭기와 조절 회로)

  • 김진목;이용호;권혁찬;김기웅;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • Wide-bandwidth SQUID current amplifier and its control electronics have been constructed for detecting pulse outputs of a superconducting microcalorimeter. The current amplifier made of a double relaxation oscillation SQUID (DROS) has a bandwidth of 1.2 MHz and typical white noise level of about 6 pA/(equation omitted) Hz. To increase the dynamic range of the current amplifier, the flux-locked loop (FLL) has additional circuits to reset the integrator and to count reset numbers which present the number of passed flux quanta. In this system, dynamic range covers from -65 mA to +65 mA. SQUID electronics are controlled by software to get the optimum FLL condition, and to control the current to bias the transition edge sensor (TES). The electronics are shielded from the outside electromagnetic noises by using an aluminum case of 66 mm ${\times}$ 25 mm ${\times}$ 100 mm, and consist of 2 separate printed-circuit-boards for the current amplifier and the control electronics, respectively. The SQUID current amplifier and its control electronics will be used in TESs for detecting photons such as UV and X-ray with high energy resolution.

  • PDF

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

Gain characteristics of SQUID-based RF amplifiers depending on device parameters

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.10-14
    • /
    • 2019
  • Radio-frequency (RF) amplifiers based on direct current (DC) superconducting quantum interference device (SQUID) have low-noise performance for precision physics experiments. Gain curves of SQUID RF amplifiers depend on several parameters of the SQUID and operation conditions. We are developing SQUID RF amplifiers for application to measure very weak RF signals from ultra-low-temperature high-magnetic-field microwave cavity in axion search experiments. In this study, we designed, fabricated and characterized SQUID RF amplifiers with different SQUID parameters, such as number of input coil turn, shunt resistance value of the junction and coupling capacitance in the input coil, and compared the results.

Behavioral response of purpleback flying squid Sthenoteuthis oualaniensis (Mollusk; Cephalopod) to the flashlight artificial bait colors

  • Lefrand Manoppo;Silvester Benny Pratasik;Effendi P. Sitanggang;Lusia Manu;Juliaan Cheyvert Watung
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.5
    • /
    • pp.336-343
    • /
    • 2023
  • This study aimed to know the response of deep-sea squid Sthenoteuthis oualaniensis to the light colors of the artificial bait. This experiment used the commercial artificial flashlight baits commonly sold in the fishing shop. The bait has several different light color combinations. The light colors were modified into several light colors by inactivating certain colors and used as treatments. The study is expected to be able to find flashlight bait's most effective color for squid fishing. We applied red-green, green, blue, and commercial bait lights in this study. Each treatment has 3 replications. The effect was expressed as the amount of squid caught. Data were analyzed by one-way analysis of variance. Results showed a significant effect on the number of squid catches. There was significantly different squid catches among the treatments. It indicates that this artificial flashlight bait could be developed to maximize squid catches. This finding can be used for the local fishermen's income and the squid fisheries development.

Fabrication and Characteristics of Integrated Nb DC SQUID (집적화된 Nb DC SQUID 소자의 제작 및 특성)

  • Lee, Yong-Ho;Gwon, Hyeok-Chan;Kim, Jin-Mok;Park, Jong-Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.277-281
    • /
    • 1992
  • We have designed, fabricated and tested an integrated planar DC SQUID which incorporates input coil and mofulation coil in thin film structure. The SQUID uses Nb /Al-oxide /Nb Josephson junctions and Pd shunt resistors, and the SQUID loop incorporates two rings connected in series forming figure '8' structure and has the advantage of a negligibly small circulating current for the spatially homogeneous noise fields. The devices were fabricated using photolithographic technique, RF magnetron sputtering, anodic oxidation for insulation and lift-off process. The preliminary test of the fabricated SQUID at 4.2 K showed that the flux-voltage characteristics were smooth enough to adopt standard readout system, and the voltage noise was too small to be measured by direct method and so the white noise was thought to be less than $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$.

  • PDF

An ultra low-noise radio frequency amplifier based on a dc SQUID

  • Andre, Marc-Olivier;Kinion, Darin;Clarke, John;Muck, Michael
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.2-6
    • /
    • 2000
  • We have developed an extremely sensitive radio frequency amplifier based on the dc superconducting quantum interference device (dc SQUID). Unlike a conventional semiconductor amplifier, a SQUID can be cooled to ultra-low temperatures (100 mK or less) and thus potentially achieve a much lower noise temperature. In a conventional SQUID amplifier, where the integrated input coil is operated as a lumped element, parasitic capacitance between the coil and the SQUID washer limits the frequency up to which a substantial gain can be achieved to a few hundred MHz. This problem can be circumvented by operating the input coil of the SQUID as a microstrip resonator: instead of connecting the input signal open. Such amplifiers have gains of 15 dB or more at frequencies up to 3 GHz. If required, the resonant frequency of the microstrip can be tuned by means of a varactor diode connected across the otherwise open end of the resonator. The noise temperature of microstrip SQUID amplifiers was measured to be between $0.5\;K\;{\pm}\;0.3\;K$ at a frequency of 80 MHz and $1.5\;K\;{\pm}\;1.2\;K$ at 1.7 GHz, when the SQUID was cooled to 4.2 K. An even lower noise temperature can be achieved by cooling the SQUID to about 0.4 K. In this case, a noise temperature of $100\;mK\;{\pm}\;20\;mK$ was achieved at 90 MHz, and of about $120\;{\pm}\;100\;mK$ at 440 MHz.

  • PDF

Climate Change and Expansion of Squid Catches in Korea (한국에서의 기후변화와 오징어 어획의 확장)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.516-524
    • /
    • 2017
  • Objectives: The annual catch of the common squid Todarodes pacificus in Korean coastal waters has gradually increased since the late 1980s. We investigated the long-term effects of climate variability on the variation in catches of the squid in the offshore fisheries of Korea. Methods: Moving average method, correlation analysis, and regression analysis were used to determine the relationship between the environmental factors and fluctuation in the catch of the squid during the past 30 years (1981- 2010). A ten-year moving average was calculated and used for each variable. Results: Squid catches in Korean coastal waters increased over time, and there were significant variations within every ten years (p < 0.001). Air temperature, atmospheric pressure, and wind grade among the meteorological factors, alongside sea surface temperature (SST) and concentrations of phosphate phosphorous, and nitrite/nitrate nitrogen in the sea water increased and were positively related with the catch size of squid (p < 0.001). However, salinity decreased and was negatively related with the catch size (p < 0.001). The increase in air temperature and SST was almost parallel, although there was a time lag between the two factors. Conclusion: These results suggest that there is a causal association between climate change and squid populations. Climate change, especially ocean warming, appears to have been largely favorable for squid range expansion into Korean seas. Although the expansion may be helpful for the human food supply, the safety of the squid caught should be monitored since the concentrations of phosphorous and nitrogen in the sea water increased, which indicates that Korean seas have grown gradually more polluted.

Fishing efficiency of LED fishing lamp for squid Todarodes pacificus by training ship (실습선에 의한 LED 집어등의 오징어 어획성능)

  • An, Young-Il;Jeong, Hak-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • This study surveyed the fishing efficiency for Japanese common squid based on improvements made to LED fishing lamps by utilizing the training ship of Gangwon Provincial College. The training ship, Haesong-ho (24 tons), was equipped with seventy-two 150W electric power LED fishing lamps (10.8kW), and their fishing efficiency and fuel consumption level were surveyed for a total of ten times during the period between June 15, 2009 and July 27, 2009. In addition, the training ship was equipped with seventy-one 300W electric power LED fishing lamps (21.3kW) and their fishing efficiency and fuel consumption level were surveyed for a total of five times during the period between January 17, 2010 and August 4, 2010. In order to compare the fishing efficiency of LED fishing lamps, the catch of another fishing vessel equipped with Metal Halide (MH) fishing lamps of 120kW for the same period and at the same fishing grounds. The fuel consumption levels during the fishing operation of Haesong-ho was about 1,047.7 liters which was approximately 19.9% of the total fuel consumption level of 5,262.6 liters, and the fuel consumption level per operation hour was on average 9.2 liters. The number of Japanese common squid caught by the LED fishing lamp-equipped fishing vessel ranged from 12 to 1,640 squid for each fishing trial and the average quantity was 652. The number of Japanese common squid caught by the MH fishing lamp-equipped 10 fishing vessels ranged from 40 to 4,800 squid and the average quantity was 2,055. The fishing of Japanese common squid was done by the use of hand lines and an automatic jigging machine. The number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 50.8% to 49.2% with respect to the LED fishing lamp-equipped fishing vessel. However, the number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 86.4% to 13.6% with respect to the MH fishing lamp-equipped fishing vessel where most of the catch was made by hand lines. On the other hand, in comparing the number of Japanese common squid caught per automatic jigging machine, the number of squid caught by the LED fishing lamp-equipped fishing vessel was about the same or greater than the number of squid caught by the MH fishing lamp-equipped fishing vessel.