• Title/Summary/Keyword: SP4T

Search Result 550, Processing Time 0.03 seconds

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Production and Action of Microbial Piscicidal Substance (미생물에 의한 살어성물질의 생성 및 그 작용)

  • 도재호;서정훈
    • Microbiology and Biotechnology Letters
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 1978
  • Piscicidal substance produced by Streptomyces sp. isolated from soil was toxic against various kinds of fish. After extraction with CH$Cl_3$ from the culture medium, the substance was purified by avicel column chromatography. In order to test toxicity, various kinds of fish were subjected to the acqueous solution of 100 us of the substance per liter of water. Generally, the substance was toxic to most fish, but Macropodus chinenes and Misgurnus mizolepis are resistant to the substance than Gobius similis and Pseudorasbora parva. The substance was stable at pH range, 3.0 to 7.0, but labile at alkaline pH, and to heat as well. Succinic dehydrogenase on most of tissue cell of Cyprinus carpio was inhibited by this substance strongly, but spinal cord was not inhibited. By addition of Cu and Pb salts to the culture medium, piscicidal substance producibility was activated.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Current Status and Transition of the Prevalence of Intestinal Parasitic Infections in Korea (한국(韓國)에 있어서의 장내기생충감염(腸內寄生虫感染)의 현황(現況)과 추이(推移))

  • Kim, Dong-Chan
    • Journal of agricultural medicine and community health
    • /
    • v.9 no.1
    • /
    • pp.83-108
    • /
    • 1984
  • Out of a total of 58 species of helminthic and protozoan parasitic infections in Korea, so far 38 species were reported as intestinal parasites of man. Quite a few species of the intestinal parasitic infections have long been prevalent throughout the country and this has been a significant public health problem. In this paper, current status and transition of the intestinal parasitic infections in the past years were presented. Chronological reviewing of data show background and prospects of change in the prevalence of infections. In the national prevalence survey on parasitic infections conducted once every five years since 1971, stool examinations were done by both cellophane thick smear and brine flotation techniques. Every egg positive case of Ascaris lumbricoides and Clonorchis sinensis was further examined by Stoll's dilution egg counting technique. In 1981, perianal swab using adhesive cellulose tape was added for Enterobius infection. For protozoan cyst examination conducted by province and city in '81, fecal specimens were fixed in SAF solution and examined by the formalin-ether concentration technique. High prevalence of parasitic infection in ana before the 1960s can be easily understood from the data given by the Ministry of Health and Social Affairs in 1967. From a parasite control point of view, the 1960s was the preparatory period particularly for control of soil-transmitted helminthiasis. Several organizations which have contributed to parasite control were founded in this period and the prevention law of parasitic infections was passed in '66. In the '70s, overall prevalence rates of the common intestinal parasitic infections, which were highly prevalent in the past were turned into reduction phase for the first time. The '80s can be said to be an active control period of parasitic infections. Intestinal helminths According to the reports of the national prevalence survey on parasitic infections, the prevalence of helminthic infections was 84.3%(number of person examined:24,887) in '71, 63.2%(27,178) in '76, and 41.1%(35,018) in '81. By area, the prevalence rate in '81 was 35.1%(20,569) in urban areas and 49.6%(14,447) in rural areas. Intestinal nematodes Ascaris lumbricoides The prevalence of Ascaris infection has decreased significantly in recent years. Among students, the prevalence was 55.4%, in '69 and decreased to 4.7% in '83. In the national prevalence surveys, the prevalence decreased to 13.0% in '81 from 54.9% in '71. By area, the prevalence decreased to 8.5% in '81 from 46.4% in '71 in urban area and 19.4% in '81 from 59.6% in '71 in rural area. By age, the prevalence has become in recent years relatively even in all age groups, although higher prevalence used to be seen in young age groups of around 10 years old, particulary in the highly prevalent rural areas. By sex, the prevalence was higher in the female than in the male. Unfertilized egg positive rates among the ascariasis cases increased gradually up to 55.4% on the average in '81. The intensity of the infection was also significantly decreased. Trichuris trichiura Trichuris infection had also decreased to 23.4% in '81 from 65.4% in '71. By area, the decreasing tendency of the prevalence became faster in urban areas than in the rural areas. The prevalence in urban and rural areas in '71 was 69.7%, and 63.1% respectively and decreased to 19.5% and 29.0% respectively in '81. By age, the prevalence reached a peak at the 10-14 age group and showed relatively even distribution throughout all age groups. By sex, the prevalence was close in young age groups, but in the 30s or over age group, especially in rural area, the prevalence was significantly higher in the female than in the male. The prevalence has much fluctuated depending in the area. The prevalence in rural areas surveyed in the '80s shows a range between 20.9% and 73.7% by locality. It is anticipated that the prevalence of Trichuris infection will drop more rapidly, when mass treatment is conducted. Hookworms Hookworm infection by mostly Ancylostoma duodenale and a few by Necator americanus has decreased to a negligible levels in recent years. In the national prevalence surveys, the prevalence was 10.7% in '71, 2.2% in '76, and 0.5% in '81. The prevalence was higher in rural areas than in urban areas. Wide application of multi-specific anthelminthics in the ascariasis control programmes conducted in the past decade appear to have been effective against hookworm infection. Trichostrongylus orientalis As in the case with hookworm infection, the prevalence of Trichostrongylus infection has reached a negligible levels. In the national prevalence surveys, the prevalence was 7.7% in '71, 1.0% in '76 and 0.2% in '81. Enterobius vermicularis In the national prevalence survey in '81, the egg positive rate was 12.0%. Higher prevalence is expected when examined repeatedly. The prevalence rate was 10.3% in urban area and 14.6% in rural area. In recent surveys conducted in rural areas among schoolchildren, the prevalence was 32.4% in Gimhae Gun in '82 and 64.1% in Yeongyang Gun in '83. By age, the egg positive rate was higher in young age groups of around 10 and sharply decreased in age groups of around 20 and then somewhat increased again in middle age groups. By sex, the prevalence was higher in the female than in the male. Strongyloides stercoralis Strongyloides stercoralis infection has rarely been found in Korea. Three cases were reported in 1914. And 0.1-0.5% were found infected out of 2,642 persons examined at the prisoner-of-war camp on Geojedo in 1956. One case was reported in '54 and '82, respectively. Anisakis spp. No systematic survey has been conducted for anisakiasis In Korea. So far, only several cases have been found 1 case in Seoul in '71, 5 cases in Busan in '81 and 1 case in Busan in '84. Intestinal trematodes Metagonimus yokogawai In the national prevalence survey conducted in 1981, the egg positive rate was 1.24% on the average. High endemic areas are located in the southwestern part of Korea. The prevalence in Hadong Gun was 29.1% on the average in '79. In a survey conducted in 76, the prevalence was 44.0% in Gwangyang, 55.0% in Gogseung and 29.0% in Gurye. The infection is closely correlated with raw sweetfish consumption in these areas. Other intestinal trematodes A human case of Heterophyes heterophyes was reported in 1914. Several species were reported in the '80s : 17 cases of Fibricola seoulensis, 9 cases of Pygidiopsis summa, 8 cases of Heterophyes heterophyes nocens, 1case of Heterophyopsis continua, 2 cases of Stellantchasmus falcatus, 1 case of Stictodora sp., 1 case of Echinostoma hortense, and 4 cases of Echinochasmus japonicus. As the intermediate hosts, snakes and frogs play a role for F.seoulensis and fish for the rest of the species. Intestinal cestodes Taenia saginata and T. solium Egg positive rates in the national prevalence survey were 0.7% in '76 and 1.1% in '81. The prevalence in '81 was 0.6% in urban area and 1.8% in rural area. The proglottid positive rate in Jeju Do was 19.2% on the average. On Udo, Jeju Do in 1983, the egg positive rate among the inhabitants was 2.9%. Hymenolepis nana In the national prevalence survey, egg positive rates were 0.6% in '76 and 0.4% in '81. No difference was seen in the prevalence by area and sex. Hymenolepis diminuta Infected cases were reported : 3 in '64 and I in '66. Egg positive rate in '81 was 0.01% in the national prevalence survey. Diphylobothrium latum So far, about 30 cases have been reported. The cases have been reported more frequently in recent surveys. Mesocestoides sp. A case was reported from a hospitalized patient in Seoul in '67. Spirometra erinacei Two cases were reported in '84 following reidentification of the adult worms collected in '74. Intestinal protozoa Out of a total of 23 species of human protozoan infections in Korea, 13 species were reported as intestinal protozoa : Entamoeba histolytica, E coli, Endolimax nana, Iodamoeba b$\ddot{u}$tschlii, Dientamoeba fragilis, Giardia lamblia, Chilomastix mesnilii, Embadomonas sp., Enteromonas hominis, Trichomonas hominis, Isospora belli, I. Hominis(Sarcocystis hominis), and Balantidium coli. Since the first report on intestinal protozoan infections in 1925, there have been quite a few survey data on the prevalence of the infection. It was found reviewing the data chronologically that up to the early '70s the infection was prevalent around a 30-50%. After that, the protozoan cyst positive rate has shown the tendency of gradual decrease throughout the country. Protozoan cyst survey conducted in Seoul and several provinces in 1981 revealed infection rates of 8.9%(1,310) in Gangweondo, 10.7%(1,703) in Gyenggi Do, 11.7%(1,032) in Jeonra Buk Do, 9.1%(4,116) in Jeonra Nam Do, and 1.4%(5,275) in Seoul. Entamoeba histolytica In the survey conducted by province in '81, the cyst positive rate was 0.8% in Gangweon-do, 0.3% in Gyeonggi Do, 1.4% in both Jeonra Buk Do and Jeonra Nam Do, and 0.2% in Seoul. Giardia lamblia In the survey by province in '81, cyst positive rates were 2.2% in both Gyeonggi Do and Jeonra Buk Do, 1.9% in Jeonra Nam Do, 0.5% in Gangweon Do, and 0.9% in Seoul. Balantidium coli Two cases were reported. One in 1930 and the other in '74. Isospora belli and I. Hominis(Sarcocystis hominis) Isospora belli was reported : 1 case in '56 and 3 cases in '66. I. Hominis, recently identified to be synonymous with Sarcocystis hominis, was reported : 3 cases in '66. Other intestinal protozoa The protozoan parasites other than the above mentioned are generally treated as commensal, although some of them are considered to be pathogenic. The data of '81 show that about 10% of the inhabitants are still infected with protozoa.

  • PDF

Effect of Environmental Variables on Changes in Macrobenthic Communities in the Coastal Area of Inchon, Korea (인천연안 대형저서동물 군집 변동에 미치는 환경요인의 영향)

  • YU Ok Hwan;KOH Byoung-Seol;LEE Hyung-Gon;LEE Jae-Hac
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.5
    • /
    • pp.423-432
    • /
    • 2004
  • In coastal area of Inchon, dredging and the disposal of dredged material for sea-wall construction and reclamation have increased in recent years. These activities may impact the benthic environment and result in changes in benthic communities, but little information is available on the extent and direction of these changes. We investigated whether there have been changes in the dominant macrobenthic species and benthic community over the last decade, and explored the relationship between environmental variables and spatial patterns of macrobenthic community structure. We sampled macrobenthos and recorded environmental variables in the coastal habitats of Inchon in March and June 2004. In total, 212 macrobenthic species were recorded during this study, predominately crustaceans $(34{\%})$, mollusks $(32{\%})$ and polychaetes $(21{\%})$. The mean density of macrobenthos was $1,393\;ind./m^{2}$.The most abundant species was Amphioplus japonicus $(20.5{\%})$, followed by Heteromastus filiformis $(14.4{\%})$, Theora fragilis $(8.2{\%})$ and Ampharete sp. $(4.0{\%})$. Over the past decade the dominant macrobenthic species in this area shifted. Multivariate analysis (multidimensional scaling) revealed significant differences in community structure among three regions: the middle part of the sampling area (B), site 8 (C) and other sites (A). Mean density varied significantly among the three regions, but no differences in the number of species and diversity (H') were observed. The distribution of the macrobenthic community was affected by environmental variables such as percentage sand content and sediment kurtosis. Species that were important in different areas included A. japonicus in region A, Raeta puchella in region B and T. fragilis in region C. The important species in regions B and C were filter-feeding bivalves, and the abundance of these species may be related to the increase in percentage sand content. We suggest that the sediment composition (percentage sand content) may be an important factor in determining the dominant species and structure of the macrobenthic communities in coastal Inchon. Long-term monitoring programs are necessary to understand ongoing changes in the benthic communities of this area.

Study of Anti-inflammatory Activity of 7 Herbal Prescription Effective for Sleep Disorders and Atopic Dermatitis (수면 장애 및 아토피피부염에 효과적인 7 가지 한약 처방의 항염증 활성 연구)

  • Choi, Min-Jin;Nguyen, Ly Thi Huong;Jeong, Jeonghwa;Park, Minyoung;Yoon, Joohee;Lee, Byung-Wook;Yang, In-Jun;Shin, Heung-Mook
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.56-63
    • /
    • 2021
  • This study was conducted to find a candidate prescription with anti-inflammatory efficacy of 7 herbal prescriptions known to be effective in atopic dermatitis and sleep disorders in Korean medicine. The anti-inflammatory of the 7 herbal prescriptions extracts were evaluated by ELISA assay and Western blot assay. 7 herbal prescriptions, Seongyutang(SU), Danseontoetang(DST), Sotosajahwan(ST), Jisiljagyagsan(JJ), Seokchangpo(SCP), Wiryeongseon(WLS), Gogojohwan(GGJ) 30 % EtoH extract was used for in vitro experiments. In TNF-α + IFN-γ(TI) stimulated HaCaT cells, all 7 herbal prescriptions reduced TARC and MDC production, and JJ strongly reduced TARC and MDC production at 100 ㎍/ml concentration. SCP strongly reduced MDC production at 10 ㎍/ml and 100 ㎍/ml concentration. In addition, in substance P(SP)/CRH stimulated HMC-1 cells, JJ strongly inhibited VEGF production at both 10 and 100 ㎍/ml concentrations. In LPS/CRH stimulated Raw264.7 cells, all 7 herbal prescriptions significantly inhibited TNF-α. PMA + Ionomycin(PI)/CRH stimulated EL4 cells, SU significantly reduced IL-4 production at both concentrations of 10 and 100 ㎍/ml. WLS significantly reduced IL-17 production at both concentrations of 10 and 100㎍/ml. This suggests that 7 herbal prescriptions have anti-inflammatory effects by reducing inflammatory cytokines in keratinocytes, mast cells and macrophages caused by inflammation. Therefore, it is expected that 7 herbal prescriptions that are effective for sleep disorders and atopic dermatitis can be used as therapeutic materials for sleep disorders and diseases associated with atopic dermatitis.

The effectiveness of sealing technique on in-office bleaching (전문가 미백시 sealing technique의 효율성에 관한 연구)

  • Lee, Yoon;Kwon, So-Ran;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.463-471
    • /
    • 2008
  • This study investigated the clinical effectiveness and safety of sealed bleaching compared to conventional in-office bleaching using a randomized clinical trial of split arch design. Ten participants received a chairside bleaching treatment on the upper anterior teeth, and each side was randomly designated as sealed or control side. A mixture of Brite powder (PacDent, Walnut, USA), 3% hydrogen peroxide and carbamide peroxide (KoolWhite, PacDent, Walnut, USA) were used as bleaching agent. The control side was unwrapped and the experimental side was covered with a linear low density polyethylene (LLDPE) wrap for sealed bleaching. The bleaching gel was light activated for 1 hour. The tooth shades were evaluated before treatment, after treatment, and at one week check up by means of a visual shade (VS) assessment using a value oriented shade guide and a computer assisted shade assessment using a spectrophotometer (SP). The data were analyzed by paired t-test. In the control and sealed groups, the visual shade scores after bleaching treatment and at check up showed statistically significant difference from the preoperative shade scores (p<.05). The shade scores of the sealed group were significantly lighter than the control immediately after bleaching and at the check-up appointment (p<0.05). Compared to prebleaching status, the ${\Delta}E$ values at post bleaching condition were $4.35{\pm}1.38\;and\;5.08{\pm}1.34$ for the control and sealed groups, respectively. The ${\Delta}E$ values at check up were $3.73{\pm}1.95\;and\;4.38{\pm}2.08$ for the control and sealed groups. ${\Delta}E$ values were greater for the sealed group both after bleaching (p<.05) and at check up (p<.05). In conclusion, both ${\Delta}E$ and shade score changes were greater for the sealed bleaching group than the conventional bleaching group, effectively demonstrating the improvement of effectiveness through sealing.

Association between Spiritual Well-Being and Pain, Anxiety and Depression in Terminal Cancer Patients: A Pilot Study (말기암환자의 영적 안녕과 통증, 불안 및 우울과의 연관성: 예비 연구)

  • Lee, Yong Joo;Kim, Chul-Min;Linton, John A.;Lee, Duk Chul;Suh, Sang-Yeon;Seo, Ah-Ram;Ahn, Hong-Yup
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Purpose: Spirituality is an important domain and is related with physical and psychological symptoms in terminal cancer patient. The aim of this study is to examine how patients' spirituality is associated with their physical and psychological symptoms as it has been explored by few studies. Methods: In this cross sectional study, 50 patients in the palliative ward of a tertiary hospital were interviewed. Spiritual well-being, depression, anxiety and pain is measured by Functional Assessment of Chronic-Illness Therapy-Spirituality (FACIT-Sp), hospital anxiety and depression scale (HADS) and the Korean version of the Brief Pain Inventory (BPI-K). The correlations between patients' spiritual well-being and anxiety, depression and pain were analysed. The association between spiritual well-being and age, gender, palliative performance scale (PPS), religion, mean pain intensity, anxiety, depression were assessed by univariate and multivariate regression analyses. Results: Spiritual well-being was negatively correlated with the mean pain intensity (r=-0.283, P<0.05), anxiety (r=-0.613, P<0.05) and depression (r=-0.526, P<0.05). In multivariate regression analysis, spiritual well-being showed negative association with anxiety (OR=-1.03, 95% CI=-1.657~-0.403, P=0.002) and positive association with the existence of religion (OR=9.193, 95% CI=4.158~14.229, P<0.001). Conclusion: In this study, patients' anxiety and existence of religion were significantly associated with spiritual well-being after adjusting age, gender, PPS, mean pain intensity, depression. Prospective studies are warranted.

The Variation of Natural Population of Pinus densiflora S. et Z. in Korea(I) -Characteristics of Needle and Wood of Chuwang-san, An-Myeon-do and Odae-san Populations- (소나무 천연집단(天然集團)의 변이(變異)에 관(關)한 연구(硏究)(I))

  • Yim, Kyong-Bin;Kim, Zin-Suh
    • Journal of Korean Society of Forest Science
    • /
    • v.28 no.1
    • /
    • pp.1-20
    • /
    • 1975
  • F$\ddot{u}$r die Erforschllng der Variationen bei der Naturpopulationen der Pinus densifiora wurden drei Populationen aus Chuwangsan (Kyong-buk), Anmyondo (Chung-nam) und Odaesan (Kangwon) Ausgewiiblt. Bei je 20 Individuen jeder Population wurden die Variationen von der Eigenschaft der $\ddot{a}$usseren Gestalt, von der anatomischen und morphologischen Eigenschaft der Kiefernadel und von der Holzqualit$\ddot{a}$t an Bohrsp$\ddot{a}$nen untersucht. Das Ergebnis der Untersuchung konnte in den folgenden sechs Punkten formuliert werden. 1. Von den Eigenschaften der $\ddot{a}$usseren Gestalt ist die Geradheit des Baumstamms, der Durchmesser der Zweige und der Winkel der Verzweigung in der Odaesan Population wlinschenswerter als in anderen Populationen. 2. Es wird festgestellt, dass sich die drei Nadelmerkmale, Anzahl der Z$\ddot{a}$hne je 0.5 cm, Anzahl der Stomata-Reihen und Anzahl der Harzkan$\ddot{a}$le, sowohl zwischen den Populationen als auch zwischen den Individuen signignifikant unterscheiden. 3. Bei der Betrachtung des Harzkanal Index, der Schichtanzahl der Hypodermis und der Entfernung der Fibrovasalb$\ddot{u}$ndel wird aufgezeigt, dass sich alle drei gepr$\ddot{u}$ften Populationen geringf$\ddot{u}$gig von der normalen Kiefer unterscheiden. 4. Zwischen den Populationen ergibt sich ein Unterschied im Prozentanteil des Spatho lzes und im spezifischen Geswicht, jedoch zeigt die Breite der Jahresrings und die Tracheidenl$\ddot{a}$nge keinen Unterschied. Das spezifische Gewicht und die Tracheidenl$\ddot{a}$nge der Individuen jeder Population ist signifikant verschieden. 5. Bei dem Alter 11-20 ist der Prozentanteil des sp$\ddot{a}$tholzes am gr$\ddot{o}$ssten und wird aber danach immer geringer bis zum Alter 30; sp$\ddot{a}$ter zeigt sich dann keine sichtbare Ver$\ddot{a}$nderung mehr. Das spezifische Gewicht sich vergr$\ddot{o}$ssert bei der Zunahme des Jahresrings, nimmt aber dann in Anmyondo und Odaesan Populationen beim Alter 21-30 wieder ab. Die Tracheidenl$\ddot{a}$nge der drei Populationen besitzen die Neigung, sich nach der zunahme der Jahresringe zu vermehren. 6. Mit diesen hier behandelten Charakteren werden ganz allgemeinen die Unterschiede der drei Kiefer populationen festgestellt. Diese Ergebnisse sind sehr bemerkenswert betrachtet vom genetischen Gesichtspunkt der waldbaumpopulation.

  • PDF

Efficacy and Safety Evaluation of an Air Sterilizer Equipped With an Electrolytic Salt Catalyst for the Removal of Indoor Microbial Pollutants (염촉매 전기분해 공기살균기의 효능 평가)

  • Sun Nyoung Yu;Ho-Yeon Jeon;Bu Kyung Kim;Ae-Li Kim;Kyung Il Jung;Gye Rok Jeon;Soon Cheol Ahn
    • Journal of Life Science
    • /
    • v.34 no.7
    • /
    • pp.500-508
    • /
    • 2024
  • Recently, there has been increasing interest in enhancing the indoor air quality, particularly in response to the growing utilization of public facilities. The focus of this study was on assessing the efficacy and safety of an air sterilizer equipped with electrolytic salt catalysts. To that end, we evaluated the antimicrobial activity of the vapor spraying from the air sterilizer and its cytotoxicity in condensed form on human cell lines (HaCaT, BEAS-2B, and THP-1). Against the test organisms, which comprised five bacterial strains (Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, Salmonella typhimurium) and one fungal strain (Candida albicans), the air sterilizer exhibited relatively high antimicrobial activities ranging from 10.89 to 73.98% following 1 and 3 hr of vapor spraying, which were notably time-dependent. Importantly, cytotoxicity assessments on human cells indicated no significant harmful effect even at a 1.0% concentration. Comprehensive safety evaluations included morphological observations, gene expression (Bcl-2, Bax) tests, and FACS analysis of intracellular ROS levels. Consistent with previous cytotoxicity findings, these estimates demonstrated no significant changes, highlighting the air sterilizer's safety and antimicrobial activities. In a simulated 20-hr operation within an indoor environment, the air sterilizer not only showed an 89.4% removal of total bacteria but also a 100.0% removal of Escherichia sp. and fungi. This research outlines the potential of the developed electrolytic salt catalyst air sterilizer to effectively remove indoor microbial pollutants without compromising human safety, underscoring the solution that it offers for improving indoor air quality.