• Title/Summary/Keyword: SP-2331

Search Result 4, Processing Time 0.023 seconds

Comparison of Dioxin Analytical Results Between SP-2331 and DB-5MS Capillary Columns in the HRGC/HRMS Analysis (HRGC/HRMS에 SP-2331 및 DB-5MS 컬럼 사용시 다이옥신 결과의 비교)

  • Hong, Jongki;Yang, Jeong-Soo;Shin, Jung-Hwa;Ahn, Yun-Gyong;Lee, Dai-Woon
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.184-191
    • /
    • 2004
  • In this study, the separation of toxic dioxin 2,3,7,8-congeners by DB-5MS and SP-2331 GC columns which are widely used in HRGC/HRMS analysis was examined. Through the dioxin analysis of column performance check standard solution and fly ash sample, the isomer specific separation of 2,3,7,8-substituted dioxins from tetra to hexa-isomers on DB-5MS and SP-2331 columns were studied. The effect of I-TEQ value by these columns was also studied. The total concentrations of toxic dioxins for the column performance check standard solution were 508.4 ng/mL analyzed by DB-5MS and 515.8 ng/mL analyzed by SP-2331, respectively. The I-TEQ value obtained by both columns was shown to be almost equivalent for the column performance check standard solution and fly ash sample.

Quantification and Resolution of Dioxins on Capillary Columns (캐필러리 컬럼 종류에 따른 다이옥신 이성체 분리능과 정량 특성 변화)

  • Kim, Jong-Guk;Park, Jin-Soo;Kim, Kyoung-Sim;Lee, Geun-Hee;Kim, Shin-Jo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • The analysis of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzo furans(PCDFs) was performed by using four different gas chromatographic columns (SP-2331, DB-5, DB-17 and DB-DIOXIN). The data reported is pertaining to flue gas, fly ash, ambient air, soil and fish. The difference in quantification of samples according to four columns was observed, it was noted that major difference was observed in the flue gas when compared with soil, fly ash, ambient air and fish. The quantification of the same samples according to four columns it was also found that DB-5 column have the highest concentration whereas SP-2331 column showed the lowest concentration. The quantification of DB-17 column for 1,2,3,6,7,8-HxCDF was found to be twice and three times higher when compared with other columns, whereas the quantification of DB-DIOXIN column for 1,2,3,7,8-PeCDD was also found to be over estimated twice when compared with other columns.

Separation properties of 209 PCB congeners on capillary columns and identification of PCBs congeners in aroclor standards for source identification (오염원 해석을 위한 폴리염화비페닐류(PCBs) 209 이성체의 컬럼별 분리 특성과 Aroclor 표준품의 이성체 확인)

  • Kim, Kyoung-Soo;Kim, Kyeo-Keun;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.352-364
    • /
    • 2006
  • This study was performed to search for useful separation properties and elution orders of three GC columns (DB-1, DB-5MS, SPB-Octyl) for 209 PCBs congeners using M-1668A-0.01X-SET of the AccuStandard Inc.. In addition, to confirm the quantitative peak in peak pattern method, the IUPAC Nos. of PCBs congener peaks were identified with 4 Aroclor standards (Aroclor-1242, 1248, 1254 and 1260). The separation property of dioxin-like PCBs congeners by four columns (DB-1, DB-5MS, SP-2331 and SPB-Octyl) was excellent in SP-2331. DB-1 and SPB-Octyl columns are necessary to use with a column of other types.

Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM) (인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가)

  • Youn, Yeu Young;Park, Deok Hie;Lim, Young Hee;Cho, Hye Sung
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.376-385
    • /
    • 2009
  • In our study, the accuracy for measurement of seventeen 2,3,7,8-substituted PCDDs/PCDFs in certified reference material (CRM) which is the sample of homogeneous sediment matrix taken from an area known to have significant chemical contamination, particularly PCBs (polychlorinated biphenyls), was evaluated. Though the methodology in this study followed the official method of unintentionally produced persistent organic pollutants (UPOPs) announced by the Ministry of Environment of the Republic of Korea in 2007, there were slight changes using additional purification step by activated carbon column because the interferences of sample were not sufficiently removed when only multi-silica column and alumina column have been used for purification. The |En| number proposed by the Korea Research Institute of Standards and Science was used for a valuation basis of the accuracy. The |En| numbers of seventeen 2,3,7,8-substituted PCDDs/PCDFs have been indicated as 1 and below, they were decided "Pass" in this test, when DB-5MS column and SP-2331 column were used together. Because 1,2,3,7,8-PeCDD and #169-HxCB were not separated on DB-5MS column, the ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA 1613. It is possible to distinguish them in HRGC/HRMS analysis.