• 제목/요약/키워드: SOFT X-RAY

검색결과 407건 처리시간 0.032초

종격동에 발생한 연골종 -1예 보고- (Mediastinal chondroma -one case report-)

  • 송인석
    • Journal of Chest Surgery
    • /
    • 제19권2호
    • /
    • pp.347-351
    • /
    • 1986
  • Soft-tissue chondroma was very rare in incidence and thought to be benign. Recently, we operated upon a 13 year-old female with a chondroma of the middle mediastinum, which was incidentally detected in chest X-ray as mediastinal mass, measured about 10x8x7 cm in size and completely resected via thoracotomy.

  • PDF

Comparative Studies on Cotton Seed Germinability with Tetrazolium Viability Test and X-ray Contrast Methods

  • Na, Young-Wang;Shim, Sang-In;Chung, Jung-Sung;Rho, Il-Rae;Kim, Seok-Hyeon
    • 한국작물학회지
    • /
    • 제59권2호
    • /
    • pp.188-193
    • /
    • 2014
  • Seed viability testing provides valuable information for assessing seed lot germinability. However, most testing methods require destruction of seed prior to test. Because the dissected seeds for viability test cannot be used further evaluation, the nondestructively X-ray photography technique that can be applied for the evaluation of seed quality has been developed. In order to know the validity and accuracy of X-ray photography technique in seed evaluation test that conducted to remove the abnormal seed from a seed lot, we have compared the results from tetrazolium viability test, germination test and X-ray contrast method in cotton. Metallic salts treatment increased the efficiency of X-ray photographic method by enhancing the penetration of X-ray in abnormal or damaged seeds rather than normal seeds that have strong and well-organized tissues in seed. Cotton seeds presoaked for 16 hr in distilled water followed by soaking into metallic salt solution (5% NaI in water) for 60 min were easily classified seeds into dead seed and viable seed based on the radiography images obtained by X-ray radiation. We concluded that soft X-ray photography was reliable to find out the various defective characters due to heat and mechanical damage of seeds.

Bacteria를 이용한 실트와 모래의 고결화에 따른 탄산칼슘 확인 (Verification of Calcium Carbonate by Cementation of Silt and Sand Using Bacteria)

  • 박경호;김대현
    • 한국지반공학회논문집
    • /
    • 제28권6호
    • /
    • pp.53-61
    • /
    • 2012
  • 본 연구의 목적은 연약지반에 대한 미생물의 고결화 메커니즘을 확인하기 위함이다. 연약지반에 대한 미생물의 고결화 메커니즘을 확인하기 위해서 6가지 미생물 조건(무처리, 일반농도처리, 고농도처리, 상층액처리, 2X 고농도처리, 25% 시료 고농도처리)으로 실험되어졌다. 전자현미경(SEM, EDX)과 X선 분석 회절기(XRD)를 이용하여 실트질시료와 느슨한 모래시료의 분석을 수행하였으며, 일반농도처리 시료에 비교하여 25% 시료 고농도처리 시료에서 입자와 입자 사이에 탄산칼슘이 더욱 명확히 관찰되어졌다. 이러한 연구결과를 바탕으로 연약지반에 대한 미생물 고결화 반응을 확인할 수 있었다.

산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구 (A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM)

  • 박응천;김재덕
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

Mechanism of the X-ray and Soft Gamma-ray Emissions from the High Magnetic Field Pulsar: PSR B1509-58

  • Wang, Yu;Takata, Jumpei;Cheng, Kwong Sang
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.91-94
    • /
    • 2013
  • We use the outer gap model to explain the spectrum and the energy dependent light curves of the X-ray and soft ${\gamma}$-ray radiations of the spin-down powered pulsar PSR B1509-58. In the outer gap model, most pairs inside the gap are created around the null charge surface and the gap's electric field separates the opposite charges to move in opposite directions. Consequently, the region from the null charge surface to the light cylinder is dominated by the outflow current and that from the null charge surface to the star is dominated by the inflow current. We suggest that the viewing angle of PSR B1509-58 only receives the inflow radiation. The incoming curvature photons are converted to pairs by the strong magnetic field of the star. The X-rays and soft ${\gamma}$-rays of PSR B1509-58 result from the synchrotron radiation of these pairs. The magnetic pair creation requires a large pitch angle, which makes the pulse profile of the synchrotron radiation distinct from that of the curvature radiation. We carefully trace the pulse profiles of the synchrotron radiation with different pitch angles. We find that the differences between the light curves of different energy bands are due to the different pitch angles of the secondary pairs, and the second peak appearing at E > 10 MeV comes from the region near the star, where the stronger magnetic field allows the pair creation to happen with a smaller pitch angle.

Pd층의 두께 변화에 따른 [Co/Pd] 다층박막의 연엑스선 방사광 분광 연구 (Soft X-ray Synchrotron-Radiation Spectroscopy Study of [Co/Pd] Multilayers as a Function of the Pd Sublayer Thickness)

  • 김대현;이은숙;김현우;성승호;강정수;양승모;박해수;홍진표
    • 한국자기학회지
    • /
    • 제26권4호
    • /
    • pp.124-128
    • /
    • 2016
  • 이 연구에서는 연 X선 광흡수 분광법(soft X-ray absorption spectroscopy: XAS)과 연 X선 자기 원편광 이색성(soft X-ray magnetic circular dichroism: XMCD)을 이용하여 수직자기이방성을 보이는 [$Co(2{\AA})/Pd(x{\AA})$] 형의 다층박막의 전자구조를 연구하였다(x = $1{\AA}$, $3{\AA}$, $5{\AA}$, $7{\AA}$, $9{\AA}$). Co 2p XAS와 XMCD 스펙트럼은 Pd 층의 두께 변화에 상관없이 서로 매우 유사하였으며, 또한 Co 금속의 Co 2p XAS와 XMCD 스펙트럼과도 매우 유사함이 관찰되었는데, 이러한 결과는 [$Co(2{\AA})/Pd(x{\AA})$] 다층박막에서 Co 이온들이 금속 결합을 하고 있다는 사실을 보여 준다. Co 2p XMCD 스펙트럼을 분석하여 두께에 따른 궤도 자기모멘트(orbital magnetic moment)와 스핀 자기모멘트(spin magnetic moment) 의 크기를 결정하였다. 이 결과에 의하면 Pd 층의 두께(x)가 $1{\AA}$에서 $3{\AA}$으로 증가할 때, 궤도 자기모멘트가 가장 크게 증가하였으며, $x{\geq}3{\AA}$ 이상의 영역에서는 별 다른 변화가 없었다. 이러한 결과는 [$Co(2{\AA})/Pd(x{\AA})$] 다층박막의 계면에서의 스핀-궤도 상호작용이 수직자기 이방성에 매우 중요한 역할을 한다는 사실을 나타낸다.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF