Conventional cepstrum has been widely used to detect echo and fault signals embedded in noise. One of the problems of finding impulse signals using the conventional cepstrum in that it is normally very sensitive to signal to noise ratio (SNR). This paper proposes a signal processing method to detect impulse signal in noisy environment. Because the proposed method minimizes the variance of signal power at a cepstrum domain, it is suggested to be called as minimum variance cepstrum (MV cepstrum). Computer simulations have been performed to understand the characteristics of the MV cepstrum. Both mathematical approach and computer simulations confirmed that the MV cepstrum is a useful technique to detect impulse in noisy environment.
In this paper, we investigate the signal to noise ratio (SNR) estimation performance of Cross quadrature amplitude modulation (QAM), which is being used for asymmetric digital subscriber line (ADSL), very high bit rate digital subscriber line (VDSL), and digital video broadcasting - cable (DVB-C), and has been found to be useful in adaptive modulation and blind equalization. At first, the symbol error rate (SER) performance of Cross QAM is analyzed in Rayleigh fading channel. Then we suggest error vector magnitude (EVM) based SNR estimation utilizing the selected constellation points having different types of decision region from one another, and verify that SNR estimation performance of each points have different performance pattern through simulation. From the simulation results, it has been found that when suggested selected constellation points are used for SNR estimation in Cross QAM, estimation performance is enhanced in additive white Gaussian noise (AWGN) channel or Ricean fading channel.
Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
/
v.7
no.1
/
pp.11-19
/
1996
Reinke's edema is used for describing varying degrees of chronic swelling of the vocal folds. The acoustic analysis of Reinke's edema has not been reported so far in this country. The purpose of this study is to clarify acoustic and aerodynamic characteristics of the Reinke's edema. Several acoustic evaluations & aerodynamic studies were done in 20 Reinke's edema patients and the data was compared with those of 20 normal controls. Videolaryngoscopy also was done to classify the severity in grading. We used C-Speech, Doctor speech science, and Phonatory function analyser. In C-Speech, we compared jitter, shimmer, and SNR(signal to noise ratio) of normal and Rrinke's edema patient. In Doctor speech science, we compared NNE(Glottal noise energy), speech fundamental frequency, voice quality between two groups. And in phonatory function analyser for aerodynamic function test, we compared speech intensity, airflow rate, and expiratory pressure between two groups. In conclusion, Reinke's edema patients showed lower voice pitches than normal, additionally jitter, shimmer, SNR(signal to noise ratio), NNE(Glottal noise energy), airflow rate, and expiratory pressure may be meaningful parameters for diagnosis and prognosis for treatment.
The purpose of this study was to investigate the problems of low signal-to-noise ratio(SNR) of single-shot turbo spin echo(SS-TSE) by quantifying numerically decreased signal to noise ratio. Thirty five patients without brain disease underwent diffusion MRI in 3T scanner from July to October in 2015. Single shot echo planar imaging(SS-EPI) which is conventionally used in MRI was taken to compared SS-TSE in SNR of medulla oblongata. As a result, SNR of SS-TSE diffusion(b0=$314.41{\pm}42.96$, b1000=$117.33{\pm}14.04$) is than SS-EPI diffusion(b0=$514.84{\pm}48.97$, b=$208.65{\pm}25.70$) lower in b=0 image(38.9%) and b=1,000 image(43.8%). Thus, diffusion MR using SS-EPI of MS-EPI should be taken for diagnosis of disease in brain stem due to decreased SNR of diffusion using SS-TSE.
The RF-CBTC (Radio Frequency-Communication Based Train Control) System is a communication system in railroad systems. The communication method of RF-CBTC system is the wireless between the wayside device and on-board device. The wayside device collects its location and speed from each train and transmits the distance from the forwarding train to the speed-limit position to it. The on-board device controlling device controls the speed optimum for the train. In the case of the RF-CBTC system used in Korea, transmission frequency is 2.4 [GHz]. It is the range of ISM(Industrial Scientific and Medical equipment) band and transmission of voice and data is performed by CDMA (Code Division Multiple Access) method. So noises are made in the AWGN (Additive White Gaussian Noise) and fading environment. Currently, the SNR (Signal to Noise Ratio) is about 20 [dB], so due to bit errors made by noises, transmission of reliable information to the train is not easy. Also, in the case that two tracks are put to a single direction, it is needed that two trains transmit reliable voice and data to a wayside device. But, by noises, it is not easy that just a train transmits reliable information. In this paper, we estimated the BER (Bit Error Rate) related to the SNR of voice and data transmission in the environment such as AWGN and fading from the RF-CBTC system using the CDMA method. Also, we supposed the SNR which is required to meet the BER standard for voice and data transmission. By increasing the processing gain that is a ratio of chip transmission to voice and data transmission, we made possible voice and data transmission from maximally two trains to a wayside device, and demonstrated it by using Matlab program.
Purpose : The quantization noise in magnetic resonance imaging (MRI) systems is analyzed. The signal-to-quantization noise ratio (SQNR) in the reconstructed image is derived from the level of quantization in the signal in spatial frequency domain. Based on the derived formula, the SQNRs in various main magnetic fields with different receiver systems are evaluated. From the evaluation, the quantization noise could be a major noise source determining overall system signal-to-noise ratio (SNR) in high field MRI system. A few methods to reduce the quantization noise are suggested. Materials and methods : In Fourier imaging methods, spin density distribution is encoded by phase and frequency encoding gradients in such a way that it becomes a distribution in the spatial frequency domain. Thus the quantization noise in the spatial frequency domain is expressed in terms of the SQNR in the reconstructed image. The validity of the derived formula is confirmed by experiments and computer simulation. Results : Using the derived formula, the SQNRs in various main magnetic fields with various receiver systems are evaluated. Since the quantization noise is proportional to the signal amplitude, yet it cannot be reduced by simple signal averaging, it could be a serious problem in high field imaging. In many receiver systems employing analog-to-digital converters (ADC) of 16 bits/sample, the quantization noise could be a major noise source limiting overall system SNR, especially in a high field imaging. Conclusion : The field strength of MRI system keeps going higher for functional imaging and spectroscopy. In high field MRI system, signal amplitude becomes larger with more susceptibility effect and wider spectral separation. Since the quantization noise is proportional to the signal amplitude, if the conversion bits of the ADCs in the receiver system are not large enough, the increase of signal amplitude may not be fully utilized for the SNR enhancement due to the increase of the quantization noise. Evaluation of the SQNR for various systems using the formula shows that the quantization noise could be a major noise source limiting overall system SNR, especially in three dimensional imaging in a high field imaging. Oversampling and off-center sampling would be an alternative solution to reduce the quantization noise without replacement of the receiver system.
This Paper presents a novel approach to single channel microphone speech enhancement in noisy environments. Widely used noise reduction techniques based on the spectral subtraction are generally expressed as a spectral gam depending on the signal-to-noise ratio (SNR). The well-known decision-directed(DD) estimator of Ephraim and Malah efficiently reduces musical noise under the background noise conditions, but generates the delay of the a prioiri SNR because the DD weights the speech spectrum component of the Previous frame in the speech signal. Therefore, the noise suppression gain which is affected by the delay of the a priori SNR, which is estimated by the DD matches the previous frame rather than the current one, so after noise suppression. this degrades the noise reduction performance during speech transient periods. We propose a computationally simple but effective speech enhancement technique based on the sigmoid type function for the weight Parameter of the DD. The proposed approach solves the delay problem about the main parameter, the a priori SNR of the DD while maintaining the benefits of the DD. Performances of the proposed enhancement algorithm are evaluated by ITU-T p.862 Perceptual Evaluation of Speech duality (PESQ). the Mean Opinion Score (MOS) and the speech spectrogram under various noise environments and yields better results compared with the fixed weight parameter of the DD.
Proceedings of the Acoustical Society of Korea Conference
/
autumn
/
pp.291-294
/
2004
본 논문에서는 잡음의 변화(variance)가 없는 정적인 통계적 특성(Stationary Static Characteristic)을 갖는 환경에서 잡음 추정을 통해 지각 필터의 성능을 개선하는 알고리즘을 제안한다. 제안된 잡음 추정 알고리즘은 입력되는 잡음에 열화 된 신호의 묵음 구간에서 추정된 잡음을 이용하여 입력되는 잡음의 SNR을 추정 후, 대역 별로 smoothing 상수 값으로 잡음 에너지를 제어하여 첨가된 잡음을 추정함으로써 초기 추정 잡음 보다 가까운 추정 잡음을 얻을 수 있게 된다. 이는 신호를 열화 시킨 잡음을 보다 정확한 추정을 제공함으로써, 지각 필터의 응답을 개선할 수 있고 더불어 잡음에 의해 열화 된 신호의 음질을 개선할 수 있다. 또한 저 대역에 영향을 미치는 잡음인 경우 다른 방법들과는 달리 음질의 개선이 뚜렷하다. 기존의 방식과 비교를 위해 다양한 신호 대 잡음 비(signal-to-noise ratio, SNR)에서 열화 된 오디오 신호를 입력으로 사용하였다. 입력 SNR이 5dB, 10dB, 15dB와 20dB의 각각의 경우에 대하여 SSNR(Segmental SNR)과 잡음 대 마스킹 비(Noise-to-mask ratio, NMR), 음질 테스트를 수행한 결과, 청감 테스트(Mean Opinion Score, MOS Test) 결과의 향상과 음질개선의 개선을 확인할 수 있었다.
It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.
This study focused on the fact that medical images that are issued at different hospitals may affect image quality on PACS when different software is used. A university hospital image was copied to the DICOM file and registered on the PACS of the university hospital B. The capacity and image quality of the software used in the university hospital were evaluated by SNR, CNR and histogram. As the compression ratio increased, SNR and CNR tended to decrease. Note that Lossless Compression decreased the data size by half compared to No Compression, but SNR and CNR did not change. As a result of the histogram analysis, the information loss due to the underflow phenomenon was conspicuous. When moving to another hospital, No compression or lossless compression method should be used. In conclusion, it is useful to use the lossless compression method, considering waiting time and economic efficiency in uploading.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.