• Title/Summary/Keyword: SMB (simulated moving bed) chromatography

Search Result 26, Processing Time 0.018 seconds

Simulation of SMB [Simulated Moving Bed] Chromatography for Separation of L-ribose and L-arabinose by ASPEN chromatography (L-ribose와 L-arabinose 분리를 위한 Aspen chromatography를 이용한 SMB [Simulated moving bed] 전산모사)

  • Lee, Seon-Hee;Lee, Eun;Kim, In-Ho
    • KSBB Journal
    • /
    • v.23 no.2
    • /
    • pp.135-141
    • /
    • 2008
  • SMB (simulated moving bed) chromatography is a very useful utility for the separation of binary system. We simulated the separation of L-arabinose and L-ribose from the mixture by using lab-scale 4(1-1-1-1)-zone SMB chromatography. Preliminary experiments of PIM (pulse input method) were performed to measure adsorption isotherms of L-ribose and L-arabinose in $NH_2$ HPLC column, and experimental and simulated results from ASPEN chromatography were compared. To find the most suitable separation condition in SMB, we carried out a simulation in $m_2-m_3$ plane base on the triangle theory and calculated operating parameters (flow rate of four zone, switching time and feed concentration and so on) using ASPEN chromatography under the conditions of linear isotherms obtained from PIM.

Simulation of IgY(Immunoglobulin Yolk) Purification by SMB(Simulated Moving Bed) (SMB(Simulated Moving Bed)를 이용한 IgY(Immunoglobulin Yolk) 분리의 전산모사)

  • Song, Sung-Moon;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.798-803
    • /
    • 2011
  • IgY(Immunoglobulin Yolk) is a specific antibody in egg yolk, and it protects human body from virus and antigen. There are a lot of egg yolk components such as lipoprotein and protein. To separate IgY, HPLC(High Performance Liquid Chromatography) and precipitation were used in a batch mode and SMB(Simulated Moving Bed) was adopted for continuous purification of yolk proteins. IgY and other proteins in yolk were separated by using three-zone SMB chromatography. Before performing SMB experiments, batch chromatography and PIM(pulse input method) were performed to find operation parameters and adsorption isotherms. The results of batch chromatography were compared with simulated results using Aspen chromatography. To find the most suitable separation condition in SMB chromatography, simulations in $m_2$-$m_3$ plane on the triangle theory were carried out. $m_2$ = 0.18, $m_3$ = 1.0 and ${\Delta}$t = 419 s are the best conditions for the highest purity of IgY. With this operating parameters(flow rate in three zone and switching time), the purity of raffinate results in 98.39% from Aspen chromatography simulation. Most of the simulation reached steadystate within second recycle.

Simulated Moving Bed(SMB) Chromatography Simulation for Loxoprofen Racemates Separation (록소프로펜 라세미체 분리를 위한 유사이동층 크로마토그래피의 전산모사)

  • Kim, In Ho;Song, Sung Moon
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.623-627
    • /
    • 2011
  • Simulated moving bed(SMB) chromatography was simulated for separating loxoprofen racemates. Aspen chromatography simulator was utilized with Henry's constants of loxoprofen racemates which were obtained by batch chromatography experiments. Raffinate stream concentrations as well as purities were calculated with various $m_2$ and $m_3$ values in the triangle diagram obtained from two Henry's constants 7.9 and 10.1. Purity values are high under the conditions that the $m_2-m^3$ coordinates are near the left central region in the diagram and feed flow rates are lower. Concentration profiles of raffinate and extract streams along SMB columns explain the purity change in the case of increasing the column numbers installed at SMB.

Preparative Chromatographic Separaction: Simulated Moving Bed and Modified Chromatography Methods

  • Yi Xie;Koo, Yoon-Mo;Nien-Hwa Linda Wang
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.6
    • /
    • pp.363-375
    • /
    • 2001
  • Chromatography has been method of choice for the separation complex biologi-cal mixtures fro analytical purpose, particularly for the last fifty years. Its use has recently been extended to preparative separation where the productivity relative to the amount of resin and sol-vent used is a matter of concern. To overcome the inherent thermodynamic inefficiency of batch chromatography, as exemplified by the partial temporal usage of the resin and dilution of the product with the solvent, chromatography has been continually modified by separation engineers. Column switching and recycling represnet some of the process modifications that have brought high productivity to chromatography. Recently, the simulated moving bed (SMB) method, which claims a high separation efficiency based on counter-current moving bed chromatography. has be-come the mainstay of preparative separation, especially in chiral separation. Accordingly, this pa-per reviews the current status of SMB along with several chromatographic modification, which may be helpful in routine laboratory and industrial chromatographic practices.

  • PDF

Simulation of (R)- and (S)- Ketoprofen Separation in Simulated Moving Bed (SMB) ((R)-케토프로펜과 (S)- 케토프로펜 분리를 위한 유사 이동층 크로마토그래피의 전산모사)

  • Lee, Il Song;Lee, In Su;Kim, In Ho
    • KSBB Journal
    • /
    • v.29 no.4
    • /
    • pp.250-262
    • /
    • 2014
  • A simulation study for finding purity changes of extract and raffinate as well as the best purity of (S)-ketoprofen in simulated moving bed (SMB) was performed with changing parameters of $m_2$ and $m_3$ from triangle theory. Aspen simulator allowed separation process simulation of (R)- and (S)-ketoprofen in SMB and compared 4-bed SMB and 8-bed SMB based on the same Henry constant and mass transfer coefficient. The 4-bed SMB consisted of 4 columns (200 mm of length, 10 mm of diameter) and the 8-bed SMB constructed by 8 columns (100 mm of length, 10 mm of diameter), and therefore total column length was made the same as 800 mm. Considering purities of both (R)-and (S)-ketoprofen, both 4-bed SMB and 8-bed SMB had the best purity when $m_2$ and $m_3$ were on 12.0 and 13.0 in the center of triangle. Taking only (S)-ketoprofen into account, 4-bed SMB as well as 8-bed SMB had the best purity when $m_2$ and $m_3$ were on 10.9 and 12.6 in the left outside triangle, and their purities were 93.3 % for 4-bed SMB and 96.9 % for 8-bed SMB.

Simulated Moving Bed [SMB] (모사 이동층 크로마토그래피)

  • Lee Chong-Ho;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.192-196
    • /
    • 2005
  • Chromatography has been a method of choice in the separation of complex biological mixtures for the analytical purpose in particular for the last half of century. In current years, chromatographic method extends its use to the preparative separation where the productivity per resin amount and solvent use become a matter of concern. Recently, simulated moving bed (SMB) method which claims high separation efficiency of the ideal counter-current moving bed chromatography has become a workhorse of preparative separation. SMB technology was developed in the early 1960s for large-scale hydrocarbon separation by UOP and approximately 120 Sorbex units have been licensed to date. Recently, SMB separation technology has been successfully extended from hydrocarbons and sugars to fine chemicals, particularly biochemicals, from laboratory to pilot to production plant. In this paper, the current status of SMB and its modifications were reviewed.

Comparing the Performance of One-column Process and Four-zone Simulated Moving Bed by Computer Simulation

  • Kim Young Sik;Lee Chong Ho;Wankat Phillip C.;Koon Yoon Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.362-368
    • /
    • 2004
  • A new one-column chromatography process, analogous to a four-zone simulated moving bed (SMB), was presented. The basic principle of the process was identical to that of a four-zone SMB. The process consisted of one chromatographic column and four tanks, instead of the four columns in the four-zone SMB (1-1-1-1), and has been used for the separation of two amino acids, phenylalanine and tryptophan, using an ion exchange resin. The operating parameters for the one-column process and four-zone SMB were obtained from equilibrium theory. Computer simulations were used to compare the performances of the new one column process to that of the general four-zone SMB, using Aspen $Chromatography^{TM}$ v 11.1. The differences between the one-column and SMB processes in terms of the purities and yields of phenylalanine and tryptophan were less than 4 and about $6\%$, respectively. The lower purities of the one-column process were due to the loss of the developed concentration profiles in the column when the liquid was stored in tanks. The one-column process gave great flexibility, and would be useful for reconstructing an existing conventional chromatography process to one of a SMB.

SMB 크로마토그래피를 이용한 loxoprofen racemate의 분리

  • Yun, Tae-Ho;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.549-553
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture such as chiral compounds in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate 1'R-25 and 1'S-2S enantiomers as a raffinate product in 95% of purity using assembled SMB chromatography system.

  • PDF

SMB 크로마토그래피를 이용한 광학이성질체의 분리

  • Yun, Tae-Ho;Park, Hui-Jun;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.506-510
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate S-ketoprofen enantiomer as a raffinate product in 85% of purity and 0.3mg/ml using assembled SMB chromatography system.

  • PDF

Separation of Amino Acids by Simulated Moving Bed Using Competitive Langmuir Isotherm

  • Yang, Yun-Jeong;Lee, Chong-Ho;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.331-338
    • /
    • 2004
  • The Separation of two amino acids, phenylalanine and tryptophan, was carried out using laboratory simulated moving bed (SMB) chromatography. The SMB process consisted of four zones, with each zone having 2 columns. The triangle theory was used to obtain the operating conditions for the SMB. The mass transfer coefficients of the two amino acids were obtained from the best-fit values by comparing simulated and experimental pulse data. The competitive adsorption isotherms of the two amino acids were obtained by single and binary frontal analyses, taking into consideration the competition between the two components. A competitive Langmuir isotherm, obtained from single-component frontal chromatography, was used in the first run, and the isotherm from binary frontal chromatography in the second, with the flow rate of zone 1 modified to improve the purity. Compared to the first and second runs, the competitive Langmuir isotherm from the binary frontal chromatography Showed good agreement with the experimental results. Also, adjusting the flow rate in zone 1 increased the purity of the products. The purities of the phenylalanine in the raffinate and the tryptophan in the extract were 99.84 and $99.99\%$, respectively.